152-388-115-03, Issue 03
Provisioning
H2TU-C-388 List 1E
April 21, 2000
19
below describes the Standard Config screen options.
describes the PairGain Config
screen options. Selections in bold typeface are the factory default settings.
Table 5.
H2TU-C-388 List 1E Standard Config Screen Options
System Settings
Screen Options
Front-panel
Display
Code
Selection
Description
Loopback Timeout
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
Loop Attenuation
Threshold
LATT
0 through
40 dB
Determines the maximum loop attenuation before an alarm is declared.
The loop attenuation threshold can only be set through the HiGain HDSL2
maintenance screens.
35 dB
Default value. Zero disables the alarm.
Margin Threshold
MARG
0 to 15 dB
Determines the minimum margin below which a system alarm can occur. Zero
disables the alarm.
The Margin Alarm Threshold can only be set through the HiGain HDSL2
maintenance screens.
4dB
Default value.
DS1 Frame
Formatting
FRMG
AUTO
Configures the HiGain HDSL2 system to operate in an auto-framing (AUTO)
mode. It detects and locks to both SF or ESF DS1 frame patterns.
Line and path performance parameters are maintained and displayed.
Unframed payloads will cause the ES-P and SES-P counters to increment.
UNFR
Same as the AUTO setting except unframed payloads will NOT cause the ES-P
and SES-P counters to increment.
DS1 Line Coding
DS1
B8ZS
Places both the H2TU-C and H2TU-R into their B8ZS modes.
AUTO
Places both the H2TU-C and H2TU-R into their AUTO framing modes.
AMI
Places both the H2TU-C and H2TU-R into their AMI modes.
H2TU-C Equalization
EQL
0
Sets the Equalizer to DSX-1 for 0 to 133 feet.
See
133
Sets the Equalizer to DSX-1 for 133 to 266 feet.
266
Sets the Equalizer to DSX-1 for 266 to 399 feet.
399
Sets the Equalizer to DSX-1 for 399 to 533 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
H2TU-R Line
Buildout
RLBO
0 dB
Sets the DS1 RLBO level toward the Customer Interface to 0 dB. H2TU-R Line
Buildout can only be set through the HDSL2 maintenance screens.
-7.5 dB
Sets the DS1 RLBO level toward the CI to -7.5 dB.
-15 dB
Sets the DS1 RLBO level toward the CI to -15 dB.
Alarm Pattern
ALMP
AIS
Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports
for LOSW and DS1 LOS.
See
for LOS/AIS response priorities.
LOS
Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports
for LOSW and DS1 LOS.
H2TU-R TLOS
Loopback
TLOS
ENA
Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input,
if enabled at the H2TU-R.
See
for LOS/AIS response priorities.
DIS
Disables TLOS logic loopback.
Network Loopback
Pattern
NLBP
AIS
Enables the H2TU-R to transmit AIS toward the CI for any network loopback.
See
for LOS/AIS response priorities.
LOS
Enables the H2TU-R to transmit LOS toward the CI for any network loopback.