background image

 

 

L

OOPBACK

 T

ESTING

Initiate loopback testing from the maintenance menus, the front-panel MODE and SEL 
pushbuttons, or a test set. Inband codes used by a test set are shown in the table below.

Table 1.

Front-Panel Alarm Messages 

 (a)

(a) Front-panel alarm messages are listed in order of priority. 

ALRM

 displays prior to any alarm message. 

Pressing the LBK pushbutton initiates an Alarm Cutoff (ACO) message.

Message

Description

PWR FEED SHRT 

 (b)

(b) Message displays repeatedly as long as the alarm condition exists, and is not included in the priority order. 

A short between the Tip and Ring of the HDSL2 pair.

PWR FEED GND

 (b)

The HDSL2 loop is grounded.

PWR FEED OPEN

 (b)

A line-power open condition.

LOSW

The HDSL2 loop has lost synchronization. 

LLOS

No signal is detected at the DSX-1 input to the H2TU-C. 

RLOS

No signal is detected at the DS1 input to the H2TU-R. 

LAIS 

Line Alarm Indication Signal.

RAIS 

Remote Alarm Indication Signal.

LRAI 

An RAI alarm (yellow) from the CPE without errors from the line unit or network.

RRAI 

An RAI alarm (yellow) from the CPE with errors from the line unit or network.

xxx-LOF

The DS1 input does not contain the ESF or SF frame pattern setting of the FRMG option. 
(xxx denotes either TUC or TUR.)

xxx-DBER 

A system DS1 Bit Error Rate (BER) alarm. (xxx denotes either Transmission Unit 
Central Office [TUC] or Transmission Unit Remote End [TUR].)

PRMF 

H2TU-R Performance Report Messaging BER threshold exceeded at far end.

PRMN 

H2TU-R Performance Report Messaging BER threshold exceeded at near end.

xxx-HBER

A system HDSL2 Block Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)

xxx-MAL

The margin on the HDSL2 loop has dropped below the threshold setting. 
(xxx denotes either TUC or TUR.)

xxx-LA

The attenuation on the HDSL2 loop has exceeded the maximum threshold value. 
(xxx denotes either TUC or TUR.)

Table 2.

Front-Panel Configuration Options Using MODE and SEL

 (a)

(a) Front-panel configuration options display in the order listed.

Display Code Description (default values in bold)

EQL

Sets the DSX-1 Equalizer to: EXT (external), 0 (0 to 132 ft.), 133 (133 to 265 ft.), 266 (266 to 398 
ft.),  399 (399 to 532 ft.),  or  533 (533 to 655  ft.). 

RLBO

Sets the H2TU-R line buildout to 0 dB, -7.5 dB, or -15 dB.

LPBK

Enables (ENA) or disables (DIS) SmartJack loopback commands. 

SPLB xxxx

Configures system for generic (GNLB) or special in-band loopback commands (A1LB, A2LB, A3LB, A4LB, 
or A5LB).

PWRF

OFF = disables HDSL2 powering; ON = HDSL2 line voltage is -180 Vdc maximum.

HBER

1E-6 or 1E-7 = alarm activates when the HDSL2 BER alarm threshold exceeds 10

-6

 or 10

-7

NONE = prevents generation of a system alarm due to BER.

DBER

Enables (ENA) or disables (DIS) fixed 24-hour DS1 BER alarm threshold.

DS1

DSX-1 line code = AUTO, B8ZS, or AMI.

LBTO

Loopback timeout = NONE, 20, 60, or 120 minutes or 8 or 24 hours.

FRMG

DS1 frame formatting = AUTO (Auto framing mode), SF (SuperFrame), ESF (Extended 
SuperFrame), or UNFR (Unframed mode).

RDA

Enables (ENA) or disables (DIS) alarm indications due to remote DS1 LOS at H2TU-R input.

ALMP

Enables system to output an alarm pattern: AIS or LOS.

BPVT

Enables (ENA) or disables (DIS) Bipolar Violation Transparency.

NLBP

Enables the H2TU-R to transmit either AIS or LOS towards CI for any network loopback. 

TLOS

Enables (ENA) or disables (DIS) a logic loopback at the H2TU-R when an LOS occurs at its DS1 input.

RTPV

Enables (ENA) or disables (DIS) remote provisioning.

PBON

Configures the power output levels of the H2TU-C network unit toward the customer to comply with 
Default (DEF) or Enhanced (ENH) templates.

PBOC

Configures the power output levels of the H2TU-C customer unit toward the network to comply with 
Default (DEF) or Enhanced (ENH) templates.

Table 3.

Front-Panel Diagnostic Messages

Message

 (a)

(a) Normal operating messages are in bold.

Description

A=xx

The highest loop attenuation (loss of signal power) measured in dB. 

ACQ

The multiplexers of the H2TU-C and H2TU-R are trying to establish synchronization.

ARM

The H2TU-C is armed to respond to Intelligent Repeater Loop (ILR) codes.

BAD RT?

The H2TU-C is not receiving a response from the H2TU-R. 

FERR

A framing bit error has occurred at H2TU-C DSX-1 input.

HES

H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.

LBPV

A local bipolar violation has been received at the DSX-1 input to the H2TU-C.

M=xx 

The power of the received HDSL2 signal relative to noise (S/N with respect to 21.5 dB).

PWR FEED OFF 

HDSL2 span power is turned off.

PWR FEED ON

HDSL2 loop is not grounded or shorted.

SIG

The transceivers of the H2TU-C and H2TU-R are trying to establish contact with each other 
over the HDSL2 loop.

Table 4.

Front-Panel System Information Messages (Scroll Mode)

 (a)

(a) To scroll through system information messages, press the MODE pushbutton for 3 or more seconds.

Code

Description

Code

Description

CODE xxxx

Line code (AMI, B8ZS).

LIST xx

Product list number.

FRM xxxx

Frame pattern received from the 
DSX-1 (SF, ESF, or UNFR).

MARG xx

Margin threshold (0 to 15 dB). Default 
is 4.

LATT xx

Loop attenuation (0 to 40 dB). Default 
is 35.

VER x.xx

Firmware version.

Table 5.

Loopback Commands

Loopback

Inband Code

Description

NLOC

1111000

DSX-1 signal is looped back to the network at the H2TU-C.

NREM

1110000

DSX-1 signal is looped back to the network at the H2TU-R.

COLB

 (a)

(a) Dual loopbacks can be initiated only from the front-panel MODE and SEL pushbuttons.

DSX-1 signal is looped back to the network at the H2TU-C and signal from the 
customer is looped back to the customer at the H2TU-C.

RULB

 (a)

DSX-1 signal is looped back to the network at the H2TU-R and signal from the 
customer is looped back to the customer at the H2TU-R.

CREM

1111110

DS1 signal from customer is looped back to the customer at the H2TU-C.

CLOC

1111100

DS1 signal from customer is looped back to the customer at the H2TU-R.

SMJK

11000

DSX-1 signal is looped back to the network at the H2TU-R SmartJack module.

Loopdown

11100

Deactivates any of the above loopbacks.

Copies of this publication or the user manual (LTPH-UM-1181-01) 
can be downloaded from the ADC website at www.adc.com. To 
order a hard copy, please contact your sales representative.

To comply with the intrabuilding wiring requirements of GR-1089 
CORE, Section 4.5.9, the shields of the ABAM-type cables that 
connect the line unit  DSX-1 output ports to the cross-connect 
panel must be grounded at both ends.

Network

H2TU-C

H2TU-R

TLOS*

NLOC

CREM

CLOC

NREM

SMJK

* When enabled, TLOS is an automatic loopback

that occurs with an LOS at the remote DS1 input.

Toward Customer

Toward Network

Customer
Premises

DS1

DSX-1

H0025-B

HDSL2

 

Four-character display

Displays status, provisioning, and

alarm messages. See tables below

for a list of message descriptions.

List number

Status LED

Reports the following conditions:

DSX-1 test access jacks
Connect standard test equipment.

Craft port
To access system maintenance, provisioning, and
performance screens, connect a standard 9-pin terminal
cable between the PC serial port and the H2TU-C
craft port.

System option buttons (for manually
setting system parameters)
Use MODE and SEL to manually modify user options,
initiate loopbacks, and display DSX-1 line parameters.
1

2

3

4

Press the MODE pushbutton for 1 second and release.

The front panel alternately displays the first system

parameter and its current setting.
Press SEL to step through all possible settings for
the displayed parameter.
Press MODE to update the parameter and advance
to the next parameter.
After scrolling through all the parameters, press SEL
to confirm changes when prompted with a CONF NO
message, or press MODE to cancel all changes.

BRG

LINE

Provides non-intrusive bridging jack access
to (IN) and from (OUT) the HDSL2 span at
the DSX-1 interface. Allows monitoring of
the DS1 payloads.

Provides splitting jack access to (IN) and
from (OUT) the HDSL2 span at the DSX-1
interface.

Maintenance Terminal Modem Settings

9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control: OFF
Terminal emulation: VT-100

H

2
T

U

C

2
3
1

MODE

SEL

OUT

BRG

IN

L

LINE

LINE

BRG

R
S
2
3
2

SETUP

STATUS

HiGain
HDSL2

H0306-A

Card-Edge Connector

14

15

16

17

18

19

20

21

22

23

24

25

Tip

DSX-1

IN

DSX-1

OUT

Ground

Factory use only

Ring

Ground

Tip 1

Ring 1

39

40

41

42

43

44

45

46

47

48

49

50

-48Vdc

1

2

3

4

5

6

7

8

9

10

11

Tip

Ring

KEY

KEY

26

27

28

29

30

31

32

33

34

35

36

37

38

12

13

Factory use only

HDSL2 Span

DCE

Retaining latch

Secures the H2TU-C.

CLEI and ECI barcode label

A Customer Remote (CREM)
or Network Local (NLOC)
loopback is in effect.

Green LED

Normal operation.

Flashing Red LED

Yellow LED

Flashing Yellow LED

System is in Armed (ARM)
mode.

HDSL2 acquisition or
system alarm.

Off

Line power is off.

Red LED

Fuse alarm.

Fuse alarm*

Factory use only

* Fuse alarm is normally floating

and at -48 Vdc when activated.

Содержание H2TU-C-231 L7

Страница 1: ...blic Press to refresh the logon screen if necessary Refer to the onscreen Help menu for navigational aids or use the to cycle through selections to activate the current setting or selection or to display a menu or to return to the parent menu or directional arrow keys to navigate to a menu or item 2 Select Config Date and Time then type the date and time 3 Select Inventory then type the circuit ID...

Страница 2: ...s to refresh the logon screen if necessary Refer to the onscreen Help menu for navigational aids or use the to cycle through selections to activate the current setting or selection or to display a menu or to return to the parent menu or directional arrow keys to navigate to a menu or item 2 Select Config Date and Time then type the date and time 3 Select Inventory then type the circuit ID H2TU R I...

Страница 3: ...s to refresh the logon screen if necessary Refer to the onscreen Help menu for navigational aids or use the to cycle through selections to activate the current setting or selection or to display a menu or to return to the parent menu or directional arrow keys to navigate to a menu or item 2 Select Config Date and Time then type the date and time 3 Select Inventory then type the circuit ID H2TU R I...

Страница 4: ...he power of the received HDSL2 signal relative to noise S N with respect to 21 5 dB PWR FEED OFF HDSL2 span power is turned off PWR FEED ON HDSL2 loop is not grounded or shorted SIG The transceivers of the H2TU C and H2TU R are trying to establish contact with each other over the HDSL2 loop Table 4 Front Panel System Information Messages Scroll Mode a a To scroll through system information message...

Страница 5: ... The power of the received HDSL2 signal relative to noise S N with respect to 21 5 dB PWR FEED OFF HDSL2 span power is turned off PWR FEED ON HDSL2 loop is not grounded or shorted SIG The transceivers of the H2TU C and H2TU R are trying to establish contact with each other over the HDSL2 loop Table 4 Front Panel System Information Messages Scroll Mode a a To scroll through system information messa...

Страница 6: ... The power of the received HDSL2 signal relative to noise S N with respect to 21 5 dB PWR FEED OFF HDSL2 span power is turned off PWR FEED ON HDSL2 loop is not grounded or shorted SIG The transceivers of the H2TU C and H2TU R are trying to establish contact with each other over the HDSL2 loop Table 4 Front Panel System Information Messages Scroll Mode a a To scroll through system information messa...

Страница 7: ...blic Press to refresh the logon screen if necessary Refer to the onscreen Help menu for navigational aids or use the to cycle through selections to activate the current setting or selection or to display a menu or to return to the parent menu or directional arrow keys to navigate to a menu or item 2 Select Config Date and Time then type the date and time 3 Select Inventory then type the circuit ID...

Отзывы: