6.5
Base Station Antenna Cable Installation
A coaxial antenna cable must be routed from the base station antenna to the microBTS
enclosure. The cable must be terminated with an N-type male connector for connection to the
microBTS antenna port or the lightning protector (accessory).
Use the following procedure to install the antenna cable(s):
1. Remove the dust cap from the N-type female connector located on the underside of the
enclosure as shown in
.
2. If specified, connect a lightning protector (accessory) to the antenna port.
3. Route the coaxial antenna cable from the base station antenna to the underside of the
enclosure.
4. Cut the antenna cable to the required length and terminate with an N-type male connector.
5. Connect the antenna cable to the lightning protector or to the antenna port.
Figure 13. Connecting Base Station Antenna Cable to Antenna Port
Note:
To comply with Maximum Permissible Exposure (MPE) requirements, the
maximum composite output from the antenna cannot exceed 1640 Watts EIRP and the
antenna must be permanently installed in a fixed location that provides at least
6 meters
(20 feet) of separation from all persons.
BOTTOM VIEW