Measuring Guidelines:

1. Measurement body location is the temple, in proximity to the temporal artery,

between the end of the eyebrow and hairline.

2. Do not place the thermometer on scarred tissue compromised by skin disorder,

open sores or abrasions and patients in trauma.

3. Temperature readings are affected by many factors including exercise and drink-

ing hot or cold beverages prior to taking a reading.

4. Consult your physician when using drug therapies that may raise the local skin

temperature in the forehead; this may lead to an incorrect reading.

5. Do not place the thermometer on skin exposed to direct sunlight, fireplace heat,

air conditioner flow and cold/warm compress therapies.

6. 

Wait at least one minute between consecutive measurements for

the unit to readjust to room temperature.

7. If the thermometer has been stored at a cold temperature, allow the unit to warm

naturally to room temperature before using.

8. Performance may be degraded if operated or stored outside stated tempera-

ture/humidity ranges.

Taking Temperature:

Use this thermometer on a clean dry forehead. Wipe away any

perspiration, move hair aside from the temporal area and apply

the probe to bare skin.

1. Press and release the Multi-Function button, all segments will

be displayed along with a single audible beep (Figure 1).

2. The previous result will be displayed for 2 seconds (Figure 2).

3. Wait for the hourglass icon to disappear (Figure 3). Do not try

to take a measurement before the hourglass icon disappears, as

this may compromise the results.

Quick Start:

1. Press and release the MULTI-FUNC-

TION button.

2. Wait 2 seconds.

3. Hold firmly to temple, wait for beep.

4. Read results.

5. Before re-measuring: wait at least 1

minute.

Содержание Adtemp 427 Temple Touch

Страница 1: ...AdtempTM 427 TempleTouchTM Thermometer USE CARE MAINTENANCE...

Страница 2: ...treme heat as they may explode WARNING It is recommended to remove the batteries from the thermometer when it is not used for a long period Do not dispose of batteries in fire recharge put in backward...

Страница 3: ...s for the unit to readjust to room temperature 7 If the thermometer has been stored at a cold temperature allow the unit to warm naturally to room temperature before using 8 Performance may be degrade...

Страница 4: ...re will be dis played for about 1 minute 7 Press and release the Multi Function button to turn the thermometer off or it will shut off automatically after 1 minute If you need to take another reading...

Страница 5: ...f the measured temperature is above 107 6 F 42 C the de vice will beep and display HI Remedy Turn the unit OFF wait 1 minute and then ON again Re take temperature using proper technique If still reads...

Страница 6: ...battery has enough remaining life for approxi mately 10 more measurements Drained Battery Battery icon appears as unit is turned on and the device turns itself OFF Remedy Replace battery Standards Co...

Страница 7: ...o 42 C 60 8 F 104 F 16 C 40 C Humidity 15 95 non condensing 4 F to 122 F 20 C 50 C Humidity 15 95 non condensing Celsius or Fahrenheit Complies with ASTM E 1112 00 standard re quirements TN LCD 0 63 X...

Страница 8: ...sulting from improper handling or use Specific legal rights stipulated in your state may guide this warranty If you have a legitimate claim under this warranty send item s postage paid to Service Cent...

Страница 9: ...us at www adctoday com register EC REP 0086 Grand Bond Electronics Ltd Room 2208 22 F CCT Telecom Bldg 11 19 Wo Shing Street Fotan New Territories Shatin Hong Kong Medes Limited 5 Beaumont Gate Shenl...

Отзывы: