background image

14

American Dryer Corp.

113279 - 9

Gas Specifications for Non-CE and Non-AGA Approved Dryers

**

Gas

Type

Nominal

Heating Value

Supply

Pressure

Gross

Heat Input

Orifice Size

Orifice

(Injector)

Quantity

Burner

Pressure

B tu /ft

3

in WC

Btu/hr

kW

DMS

mm

in WC

 Natural

1,000

7.0-13.0

26,000

7.6

40

2.489

1

3.0

 

*

Propane

2,500

11.0-13.0

26,000

7.6

53

1.511

1

10.5

Piping / Connections

Inlet connection is 3/8” N.P.T.

CE and Australian dryer connections will be B.S.P.T., all others
will be N.P.T.

There should be a minimum 6-inch (15.24 cm) clearance
between the back guard and the first bend in the gas piping
for ease of servicing.  It is recommended that a gas shutoff
valve be provided to the gas supply line of each dryer for
ease in servicing.

The size of the main gas supply line (header) will vary
depending on the distance this line travels from the gas meter
or, in the case of propane gas, the supply tank, other gas-
operated appliances on the same line, etc.  Specific
information regarding supply line size should be determined
by the gas supplier.

Heat Input / Gas Consumption / Orifice (Injector) Data

(For Non-CE [European] and Non-AGA [Australia] Models Only)

Shaded areas are stated in metric equivalents

*

Gas valve’s internal regulator disabled.

** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

NOTE: 

Undersized gas supply piping can create a low or

inconsistent pressure, which will result in erratic operation
of the burner ignition system.

Consistent gas pressure is essential at all gas connections.
It is recommended that a 3/4-inch (19.05 mm) pipe gas loop
be installed in the supply line servicing a bank of dryers.  An
in-line pressure regulator must be installed in the gas supply
line (header) if the (natural) gas pressure exceeds 13.0 in
WC (32.34 mb) pressure.

A plugged tap 1/8” N.P.T. minimum, accessible for a pressure
gauge connection, must be installed in the main gas supply
line immediately upstream of the dryers.

IMPORTANT: 

Pipe joint compounds that resist the action

of natural, propane, and butane gases must be used.

Test all connections for leaks by brushing on a soapy
water solution (liquid detergent works well).

!

 WARNING

Never test for leaks with a flame!!!

Converting from One Family

of Gas to Another _____________________

!

 WARNING

 

(CE Dryers)

This appliance must only be operated with the gas
type indicated on the dryer’s data plate.  If the
appliance is converted (gas type changed), a data
plate amendment must be obtained from American
Dryer Corporation (dryer’s serial number is required
to purchase a conversion kit).

IMPORTANT: 

Any burner changes or conversions must be

made by a qualified professional.

The dryers manufactured for Belgium, Luxemburg, Greece,
Estonia, Slovak Republic, Iceland, Malta, Poland and
Cyprus cannot be converted from one family of gas to
another.

Содержание AD22

Страница 1: ...s L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU ...

Страница 2: ...your order is processed accurately and promptly These instructions are only valid if the following country code is on the appliance If this code is not present on the appliance it is necessary to refer to the technical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the n...

Страница 3: ...cher Des erreurs de câblage peuvent entraîner un fonctionnement inadéquat FOR YOUR SAFETY Do not dry mop heads in the dryer Do not use dryer in the presence of dry cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring diagram for the dryer is located behind the control panel Table of Contents __________________ WARNING Chil...

Страница 4: ...e oil paint or wax Explosion could result Items that have been spotted or soaked with vegetable or cooking oil constitute a fire hazard and should not be placed in a tumble dryer Do not dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING Do not use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying i...

Страница 5: ...ion of this appliance may affect the operation of other types of gas appliances which take their air for safe combustion from the same room If in doubt consult the appliance manufacturer s Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed from the tumble dryer or piled or...

Страница 6: ...TION 3 8 M N P T VOLTAGE AVAILABLE 220 240V 1ø 50 60 Hz APPROXIMATE NET WEIGHT 151 lb 68 49 kg APPROXIMATE SHIPPING WEIGHT 171 lb 77 56 kg AIRFLOW 60 Hz 220 cfm 6 23 cmm 50 Hz 183 cfm 5 19 cmm EXHAUST CONNECTION DIAMETER 4 10 16 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 4 1 13 843 3 488 5 0 17 065 4 300 5 4 18 430 4 644 VOLTAGE AVAILABLE N A APPROXIMATE...

Страница 7: ...dclaundry com 7 Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Страница 8: ... exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 months inspect the ...

Страница 9: ...ssure areas NOTE Component failure due to dry cleaning solvent fumes will void the warranty EXAMPLE For a bank of four dryers two unrestricted openings measuring 10 inches by 6 inches 25 4 cm by 15 24 cm are acceptable IMPORTANT Make up air must be free of dry cleaning solvent fumes Make up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and o...

Страница 10: ...ed sheet steel not less than 26 gauge 0 0195 inches 0 50 mm thick The ductwork for this appliance must be suitable for the appliance category in accordance with national installation regulations of the country of destination Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be installed where the exhaust exits the bui...

Страница 11: ...a Canadian Electric Code CSA C22 1 IMPORTANT Failure to comply with these codes or ordinances and or the requirements stipulated in this manual can result in personal injury or component failure NOTE Component failure due to improper installation will void the warranty Each dryer should be connected to an independently protected branch circuit The dryer must be connected with copper wire only Do n...

Страница 12: ...onform to applicable requirements of National Electric Code ANSI NFPA 70 or in Canada the installation must conform to applicable Canada Standards Canadian Electric Code CSA C22 1 The ground connection may be to a proven earth ground at the location service panel For added personal safety when possible it is suggested that a separate ground wire size per local codes be connected from the ground co...

Страница 13: ...ervice the individual gas supply line of each dryer must have its own manual shutoff valve IMPORTANT The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa for non CE dryers or 50 mb for CE dryers Failure to isolate or disconnect the dryer from supply as noted can c...

Страница 14: ... orifice size NOTE Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system Consistent gas pressure is essential at all gas connections It is recommended that a 3 4 inch 19 05 mm pipe gas loop be installed in the supply line servicing a bank of dryers An in line pressure regulator must be installed in the gas supply...

Страница 15: ...lator vent cap For unregulated propane gas most countries install blocking pin ADC P N 140414 For regulated propane gas some countries remove the white plastic regulator adjustment screw under vent cap Remove spring under screw and replace with spring from kit ADC P N 140416 Replace regulator adjustment screw Install the gas train back into the dryer gas train enclosure Be sure the tab at the rear...

Страница 16: ...in dryer s gas supply line Open the panel located just below the loading door Locate the gas train and disconnect the union three electrical plugs and the gas train mounting screws from the burner Carefully slide the gas train out of the gas train enclosure The carbon ignitor located at the far end of the gas train is very fragile Remove two burner tube mounting screws and remove burner tube in or...

Страница 17: ...uits Make a complete operational check of all safety related circuits Door Switch es Hi Limit Thermostats Make a complete operational check of all operating controls Tumbler Coating The tumbler is treated with a protective coating We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating Micr...

Страница 18: ...al dryer NOTE Be sure to include the installation date when returning the warranty card s Warranty For a copy of the commercial warranty covering your particular dryer s contact the reseller from whom you purchased the equipment and request a dryer warranty form If the reseller cannot be contacted or is unknown warranty information can be obtained from the factory by contacting the Warranty Depart...

Страница 19: ...ature sensor area WARNING To avoid the hazard of electrical shock discontinue electrical supply to the dryer 90 Days Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment Clean any lint accumulation in and around the motor s casing opening NOTE To prevent damage avoid cleaning and or touching ignitor flame probe assembly Every 6 Months Inspect and remove lint acc...

Страница 20: ...lows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or propane gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the number drill size used 6 Electric Service This ...

Страница 21: ...__________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________...

Страница 22: ...ADC Part No 113279 9 06 16 22 ...

Отзывы: