2. FAULT CODES
bURNER CONTROL FAIL
- GAS MODELS ONLY POWER (24VAC) IS NOT EVIDENT AT GAS VALVE
bURNER FLAME FAIL
- The Phase 6 Microprocessor Controller (computer)
DOES NOT
SENSE FLAME VERIFICA-
TION (GAS MODEL ONLY)
bURNER SAFETY FAIL
- GAS/ELECTRIC ONLY BURNER/OVEN OPEN HI-LIMIT CIRCUIT
dRUM SAFETY FAIL
- Fault in the TUMBLER HI-LIMIT CIRCUIT
HOT
- Indicates an OVERHEAT CONDITION
LINT dOOR
- When the LINT DOOR OR DRAWER is open or there is a
fault
in the LINT DOOR/DRAWER
CIRCUIT
MAIN dOOR
- When the MAIN DOOR is open or there is a
fault
in the DOOR CIRCUIT
No AIR FLOW
-
Fault
in the SAIL SWITCH CIRCUIT (GAS/ELECTRIC MODELS ONLY)
No HEAT
- GAS ONLY IGNITION ATTEMPT FAILURE
ROTATE SENSOR FAIL
-
Fault
in the ROTATION SENSOR CIRCUIT
SAIL SWITCH FAIL
-
Fault
in the SAIL SWITCH CIRCUIT (GAS/ELECTRIC MODELS ONLY)
TEMP SENSOR CHECK TEMP SENSOR FUSE
-
Fault
in the MICROPROCESSOR TEMPERATURE SENSOR CIRCUIT