12
American Dryer Corp.
113354 - 23
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent professional in accordance with local, state, and country codes.
In the absence of these codes, the installation must conform to applicable American National Standards: National
Fuel Gas Code ANSI Z223.1/NFPA 54 and National Electric Code ANSI/NFPA 70, or in Canada, the installation
must conform to applicable Canadian Standards: Natural Gas and Propane Installation Code CSA B149.1 and
Canadian Electric Code CSA C22.1.
A. LOCATION REQUIREMENTS
Before installing the dryer, ensure the location conforms to local codes and ordinances. In the absence of such
codes or ordinances the location must conform with National Fuel Gas Code ANSI Z223.1/NFPA 54, or in
Canada, the installation must conform to applicable Canadian Standards: Natural Gas and Propane Installation
Code CSA B149.1.
1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be
removed from the floor area that the dryer is to rest on.
IMPORTANT: “The dryer must be installed on noncombustible floors only.”
2. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
3. The dryer is for use in noncombustible locations.
4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply
Requirements in Section D).
5. Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer
Enclosure Requirements in Section C).
6. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual
(refer to Dryer Enclosure Requirements in Section C).
7. The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual
(refer to Exhaust Requirements in Section E).
8. The dryer must be located in an area where correct exhaust venting can be achieved as noted in this
manual (refer to Exhaust Requirements in Section E).
IMPORTANT: The dryer should be located where a minimum amount of exhaust duct will be
necessary.
9. The dryer must be installed with adequate clearance for air openings into the combustion chamber.