Appendix A - Specifications
LTPH-TP-1047-01, Issue 1
36
March 12, 2001
H2TU-R-402 List 5E
C
RAFT
P
ORT
shows the pinout for the craft port connector and its connection to a DB-9 or DB-25 connector on a
maintenance terminal.
Figure 26.
RS-232 Craft Port Pinouts
Local and Line Power
The H2TU-R-402 can be line-powered from the H2TU-C over the HDSL2 span, or it can be powered by 48 V
local power supply applied to pins 35 and 17 as shown in
.
When the local power is applied to this unit, it automatically provides a resistive termination at its HDSL2 port.
This termination will sink 10 mA of sealing current when connected to a compatible line unit.
lists the
effect that various combinations of plugs have on sealing current operation.
Table 16.
Sealing Current vs. Plug Types
H2TU-C
H2TU-R
Sealing Current Operation
List 3E
(a)
List 5E
C sources
R terminates
List 3E
(a)
List 4E
C terminates
R sources
List 1E
(b)
, 2E
List 4E
C terminates
R sources
List 1E
(b)
, 2E
List 5E
C terminates
R terminates; no sealing current flows
(a) Including the H2TU-C-319, List 1E
(b) Except for the H2TU-C-319, List 1E
H2TU-R-402
DB-9 Connector
(DCE)
RD (Receive Data)
TD (Transmit Data)
3
2
5
DB-9 Connector
(DTE)
DB-25 Connector
(DTE)
2
3
5
3
2
7
GND
Terminal
Terminal