800-357-104-01, Revision 01
58
September 29, 2000
HMS-357 List 4 and List 5
S
ETTING
U
P
C
IRCUIT
ID
S
5
Proceed to
“Setting Up Circuit IDs” on page 58
H
Installer Signature
?
?
?
?
Date
The craft port on an HRU can be accessed for configuration whether or not it is managed by an HMU.
Refer to
“Configuring the Management Unit” on page 29
and the HRU practice for more information
about provisioning the HRU.
Step
Procedure
Installer Check
ü
ü
ü
ü
The following procedure assumes proper TAO login.
For proper login procedure, please refer to
“Using the Terminal Access Option” on
.
1
From the Shelf Status screen, enter the number of the line unit, and then press
.
H
2
From the Maintenance Terminal Main menu, select
(Enter Circuit ID#) from the Main menu to
display the line unit System Inventory screen.
H
3
Press the letter of the circuit device and enter the alphanumeric characters to be assigned to the
device, and then press
.
H
4
Choose
to confirm.
If more than 24 characters are entered, a warning beep is emitted and only the first 24 characters
are accepted.
H
5
Perform loopback testing of the line by following the instructions provided in the HRU technical
practice.
This allows verification of the integrity of the HDSL channel to the HLU as well as the DS1 channel
to the customer and the HLU DSX-1 interface. A loopback testing diagram is found on the inside front
panel on the chassis and can also be found in
“Troubleshooting and System Testing” on page 67
H
6
Repeat
through 7 for each line that you plan to activate.
H
7
Press
to exit the Network Status screen
.
H
8
“Placing the Line in Service” on page 59
.
H
Installer Signature
?
?
?
?
Date
Step
Procedure (Continued)
Installer Check
ü
ü
ü
ü
ENTER
H
ENTER
C
ESC