Installing Multiplexers
800-357-104-01, Revision 01
36
September 29, 2000
HMS-357 List 4 and List 5
HX
U
-3
5
7
Configuring DS1 Services through the HXU-357
This section provides instructions for configuring a single line from the HXU Root Menu. After the DS1 line is
configured, the line unit, any necessary doublers, and the HRU are installed as described in the sections which
follow. The final step is to place the line in service to allow reporting and lockout further changes.
The DS1 line being configured must be set to Unequipped and Out-of-Service to allow configuration
changes and prevent unwanted alarms. This is the default setting; it should not require adjustment.
If you need to change the configuration of the DS1 line, follow these instructions.
Step
Procedure
Installer Check
ü
ü
ü
ü
1
From the HXU-357 Root Menu, press
and then press
to select the Configuration
Management submenu.
H
For more information on navigating through the menu system, refer to the procedures
detailed in
“Setting Up Basic HXU-357 System Parameters in the System Administration
.
2
Press
and then press
to select Configure DS1 Interface.
H
3
Press the channel number of the HLU to be configured.
H
4
Press
and then press
to select Set the DS1 Line Code. Press
and then press
to select (B)8ZS line code. This is the default setting; it should not require adjustment. The HXU and
HLU must be configured identically.
H
If an HCC-319 List 1 and List 2 Cut-through card is installed at this location, the LBO and
line code must be selected to match the external line connected to the port.
5
Press
and then press
to select Set DS1 Line Buildout.
H
If an HCC-319 List 1 and List 2 Cut-through card is installed at this location, the LBO and
line code must be selected to match the external line connected to the port.
6
Select the number that corresponds to the appropriate line buildout value dictated by your particular
system configuration. The default is 0-133 feet. It should not require adjustment.
H
7
Repeat
2 through
6 for each service you are configuring.
H
8
Press
+
to return to the menu of the Shelf Status screen.
H
9
“Configuring the DS3 Transport through the HXU-357” on page 37
H
Installer Signature
?
?
?
?
Date
1
ENTER
2
ENTER
1
ENTER
2
ENTER
2
ENTER
CTRL
R