Appendix B: Additional Information
HRE-506 List 1 and List 2
March 28, 2000
39
R
EPLACEMENT
P
ARTS
There are seven replacement or accessory kits that are available for the HRE-506 enclosures.
lists these kits.
The HRE-506 contains LPU surge arrestors. See
“Replacing the Stainless Steel Dome Cover”
below for
replacement instructions and
for replacement part numbers. Additionally, ADC recommends
that the O-ring be closely examined whenever the housing is opened for maintenance. If the O-ring is damaged,
replace it.
Replacing the Stainless Steel Dome Cover
It is necessary to replace the following items: stainless steel dome cover, metal locking clamp, and O-ring. It is
recommended that the desiccant bags be replaced when the enclosure is opened. Use Davison Chemical Corp.
Proteck-Sorb-121 or equivalent desiccant.
Replacing the LPU Arrestor Boards
If any of the enclosure plugs experience severe lightning stress, ADC recommends replacing the LPU board for
that plug. To Replace LPU arrestor Boards, perform the following steps:
1
Clean the dome cover and clamp of dust and debris.
2
Remove the clamp and dome cover as described in
“Opening the Enclosure” on page 20
3
Remove the defective LPU board.
4
Insert a new LPU board in the vacant position.
5
Replace other defective LPU boards in the same manner. Note that the LPU board must be reattached so that
Pin 1 of the board is connected to the edge connector pin which, in turn, is connected to the green or braided
shield ground wire. If the LPU board is attached in any other way, protection will not be provided.
6
Replace the O-ring, if damaged.
7
Place the cover and clamp, and then repressurize housing, if required. For additional information, refer to
“Closing the Enclosure” on page 21
Kits 132-1010, 132-1011, 132-1013, 132-1014; 132-1038-01; and 132-1030-01 are available
to replace damaged components. Kit 132-1916-01 contains a set of nuts and bolt
mounting hardware.
The cover, clamp, O-ring, and LPU surge arrestors may be replaced in the field if they
become damaged. See
for replacement kits.
Содержание 150-2204-01
Страница 4: ...Inspecting Shipment 150 506 100 03 iv March 28 2000 HRE 506 List 1 and List 2 ...
Страница 17: ...150 506 100 03 Installation HRE 506 List 1 and List 2 March 28 2000 9 Figure 4 HRE 506 Enclosure ...
Страница 18: ...Installation 150 506 100 03 10 March 28 2000 HRE 506 List 1 and List 2 Figure 5 Pivot mounting Bracket ...
Страница 54: ...Appendix D Abbreviations 150 506 100 03 46 March 28 2000 HRE 506 List 1 and List 2 ...