150-402-111-02
Initializing the Maintenance Terminal Screens
HRU-402 List 1A
December 8, 1998
31
At the View Span Status screen you have the following options:
•
Press
to exit and return to the previous menu.
•
Press
to update the current values.
When doublers are in use,
displays:
Figure 14.
Span 1 Status Screen for Doubler Applications
HDU1 (one doubler) through HDU3 (three doublers) appear in the Span
Status screen for doubler applications. The doublers are configured along
four spans.
You can do the following:
•
Press
to return to the previous menu.
•
Press
to update current values.
•
Press
to view the next available span.
describes each status item shown in
TIME: 00:14:11
SPAN 1 STATUS
DATE: 02/02/98
CIRCUIT ID#:
ALARMS: CHREV
LOOPBACK: OFF
POWER LEVEL: HIGH
HLU
HDU1
HDSL-1 HDSL-2 HDSL-1 HDSL-2
cur/min/maxcur/min/max cur/min/max cur/min/max
MARGIN:
19/18/20
19/18/19
19/18/20
19/17/20dB
PULSE ATTN:
2727
27
27
dB
INS LOSS:
3333
33
33
dB
PPM OFFSET:
0000
-02
-03
ppm
24 HOUR ES:
00010000090001600019
seconds
24 HOUR UAS:
00025000320000400006
seconds
DS-1 STATUS
HLU
HRU
24 HOUR BPV Seconds:
00006
00035
24 HOUR UAS Count:
00010
00020
Frame type:
Unframed
Unframed
Code type:
AMI
AMI
(E)xit (U)pdate (S)pan