150-402-111-02
Initializing the Maintenance Terminal Screens
HRU-402 List 1A
December 8, 1998
29
Table 7.
Remote Terminal Menu Descriptions
Menu
Function
See
View Span
Status
Provides access to a submenu that allows you
to monitor the HDSL line between the HLU and
the HRU-402 span (non-doubler applications),
and the HLU, HDU, and HRU-402 for multi-span
applications.
System
Settings
Allows you to view all system settings.
Loopback
(a)
Mode
(a) Available only when the HRU is connected to the HLU-231 List 8x,
HLU-319 List 5x, HLU-388 List 5x or HLU-231 List 7B.
Allows system loopbacks to be initiated.
View
Performance
Data
Provides access to submenus that allow you to
view the Errored Seconds (ES) and Unavailable
Seconds (UAS) between the HLU and the
HRU-402 span (non-doubler applications), and
the available spans (doubler applications) in
15-minute intervals over a 4-hour time period.
“View Performance
Data” on page 46
View
Performance
History
Provides access to submenus that allow you to
view the ES and UAS between the HLU and the
HRU-402 span (non-doubler applications) and
the available spans (doubler applications) in
24-hour intervals over a 7-day period.
“View Performance
History” on page 49
.
View Alarm
History
Provides access to submenus that allow you to
view alarm conditions between the HLU and the
HRU-402 span (non-doubler applications) and
the available spans (doubler applications).
“View Alarm History”
on page 51
View System
Inventory
(a)
Displays the model number and ID of all circuit
plugs.
“View System
Inventory” on page 54
.
Remote Logoff
Disconnects the HRU-402 login from the line
unit.