background image

Advanced Control Equipment ACE

TM

 Safety 

 

 

 

Operation

 

(contd.) 

 

Before starting this equipment, check all safety interlocks, fire-
detection systems, and protective devices such as panels and covers.  
Make sure all devices are fully functional.  Do not operate the system if 
these devices are not working properly.  Do not deactivate or bypass 
automatic safety interlocks or locked-out electrical disconnects or 
pneumatic valves. 

 

 

Never operate equipment with a known malfunction. 

 

 

Do not attempt to operate or service electrical equipment if standing 
water is present. 

 

 

Use this equipment only in the environments for which it is rated.  Do 
not operate this equipment in humid, flammable, or explosive 
environments unless it has been rated for safe operation in these 
environments. 

 

 

Never touch exposed electrical connections on equipment while the 
power is ON. 

 
 
 
Allow only qualified personnel to perform maintenance, troubleshooting, 
and repair tasks.  Only persons who are properly trained and familiar with 
Siemens Airfield Solutions equipment are permitted to service this 
equipment. 

Maintenance and Repair 

 

 

Always use safety devices when working on this equipment. 

 

 

Follow the recommended maintenance procedures in your equipment 
manuals. 

 

 

Do not service or adjust any equipment unless another person trained in 
first aid and CPR is present. 

 

 

Connect all disconnected equipment ground cables and wires after 
servicing equipment.  Ground all conductive equipment. 

 

 

Use only approved Siemens Airfield Solutions replacement parts.  
Using unapproved parts or making unapproved modifications to 
equipment may void agency approvals and create safety hazards.

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

©

 2001 ADB Airfield Solutions, LLC 

96A0245D 

Page 4 

All rights reserved

 

Issued 5/01

 

 

Содержание ACE Series

Страница 1: ...0245 Issued February 27 2001 Rev D Aug 17 2011 www adb airfieldsolutions com ADB Airfield Solutions LLC 977 Gahanna Parkway Columbus OH 43230 USA Tel 1 614 861 1304 Fax 1 614 864 2069 Copyright 2001 by ADB Airfield Solutions LLC All rights reserved ...

Страница 2: ...scription EC No Checke d Approved Date A Released Manual 00646 WT EPD 2 27 01 Title page B Changed to Siemens sans font 00696 JY WT 5 16 01 all C Updated to new format all D Updated for Corey RH JC 8 17 11 2001 ADB Airfield Solutions LLC 96A0245D ii All rights reserved Issued 5 01 ...

Страница 3: ...oard 7 ACE Input Output Circuit Board 7 ACE Processor Circuit Board 8 ACE Lamps Out Circuit Board 8 ACE Front Panel Display Circuit Board 8 3 Theory of Operation 10 ACE Communication 10 ACE Input Output 11 ACE Failsafe Functionality 11 4 Installation Instructions 12 ACE Mounting Location 12 ACE Mounting Orientation 12 ACE Mounting Instructions 13 ACE Cable Entry and Wiring 16 ACE Wiring 17 5 ACE T...

Страница 4: ...al damages of any kind the exclusive remedy being to require such new parts to be furnished Siemens Airfield Solutions s liability under no circumstances will exceed the contract price of goods claimed to be defective Any returns under this guarantee are to be on a transportation charges prepaid basis For products not manufactured by but sold by Siemens Airfield Solutions warranty is limited to th...

Страница 5: ...nstructions provided in this section of the manual before installing operating maintaining or repairing this equipment read and carefully follow the instructions given throughout this manual for performing specific tasks and working with specific equipment store this manual within easy reach of personnel installing operating maintaining or repairing this equipment follow all applicable safety proc...

Страница 6: ...r than described in this manual may result in personal injury death or property and equipment damage Use this equipment only as described in this manual Siemens Airfield Solutions cannot be responsible for injuries or damages resulting from nonstandard unintended applications of its equipment This equipment is designed and intended only for the purpose described in this manual Uses not described i...

Страница 7: ...trical connections to local code Use only electrical wire of sufficient gauge and insulation to handle the rated current demand All wiring must meet local codes Route electrical wiring along a protected path Make sure they will not be damaged by moving equipment Protect components from damage wear and harsh environment conditions Allow ample room for maintenance panel accessibility and cover remov...

Страница 8: ...vironments Never touch exposed electrical connections on equipment while the power is ON Allow only qualified personnel to perform maintenance troubleshooting and repair tasks Only persons who are properly trained and familiar with Siemens Airfield Solutions equipment are permitted to service this equipment Maintenance and Repair Always use safety devices when working on this equipment Follow the ...

Страница 9: ... Do not attempt to service electrical equipment if standing water is present Do not service electrical equipment in a high humidity environment Use tools with insulated handles when working with electrical equipment When replacing or servicing the ACETM turn the main circuit off until the operation is complete and personnel are no longer handling equipment Maintenance and Repair contd ...

Страница 10: ...ting vault The ACETM is a universal device that can be used to control any type of CCR and or controlled element regardless of the manufacturer Each CCR and Controllable item will be connected to an ACETM The ACETM is a microprocessor based module that includes all of the communication control commands input output interface and failsafe functionality Figure 2 for the controlled element 1 2 3 4 5 ...

Страница 11: ... internal components of the ACETM The ACETM Power Supply Printed Circuit Board Shown in figure 2 provides each of the printed circuit boards with a regulated and isolated power source The ACETM Input Output Printed circuit board Shown in figure 2 provides the interface for all control and monitoring connections This board incorporates a distribution bus for interfacing internal boards In addition ...

Страница 12: ...Airfield Solutions s Current and Voltage Sensor Module which is mounted inside the CCR and is required with the Lamps Out monitoring option measures current and voltage waveforms In addition to RMS voltage RMS current apparent power VA true power and power factor the Lamps Out Printed Circuit Board in turn calculates the number of lamps burnt out Up to 16 at each brightness level The Lamps Out Boa...

Страница 13: ...ic controllers B Lighting commands are communicated over the main airfield lighting communications network to the electrical vault computer C The electrical vault computer in turn passes the lighting commands to the communication server D The communications server broadcasts the lighting commands over the ACE Redundant Communications Network E Finally the ACE unit with the corresponding address th...

Страница 14: ...that includes all of the communication control commands input output interface and failsafe functionality for the controlled element Each of the ACETM units connected to a CCR or other controllable device will have a unique factory set address and a field programmable communication address These addresses are used by the ALCS to direct lighting commands to the corresponding ACETM The ACETM in turn...

Страница 15: ...oltage and current monitoring OPTIONAL as well as field circuit cable Insulation Resistance Monitoring OPTIONAL ACE Failsafe Functionality Each ACE unit will provide a self contained failsafe feature This feature will insure default airfield lighting operation in the event of an ALCS component failure or even a complete ALCS failure In addition each ACE monitors its outputs and verifies proper com...

Страница 16: ... elements i e Regulator Generator etc Exact locations should be coordinated with the Airport Engineer Each ACE must be mounted flush against a wall or on U rails that will support all four 4 corners The unit must be oriented as seen in Figure 4 Top Mounting Holes Slotted Bottom Mounting Holes Round Figure 4 Advanced Control Equipment 4 Installation Instructions ACE Mounting Location ACE Mounting O...

Страница 17: ...ur 4 corners Make sure to mark the top portion of the slotted mounting hole as seen in Figure 4 Mounting hardware must fit through lower opening of the top slotted mounting holes as seen in Figure 4 B Drill out the marked holes and insert anchor hardware as required C Carefully remove the lid of the enclosure and disconnect the grounding strap from the main enclosure D Remove the six 6 screws that...

Страница 18: ...en in Figure 6 and put aside temporarily Figure 6 Removal of bottom access plate F Mount the MAIN enclosure using the top slotted mounting holes and secure as seen in Figure 7 Place large opening over screw and pull down securing the top mounting holes Figure 7 Securing the main enclosure G Re attach the BOTTOM access plate to the main enclosure using the six 6 screws 4 Installation Instructions c...

Страница 19: ...ctions 2001 ADB Airfield Solutions LLC 96A0245D Page 15 All rights reserved Issued 5 01 H Mount the BOTTOM access plate using the bottom round mounting holes as seen in Figure 8 Figure 8 Securing the bottom access plate 4 Installation Instructions contd ...

Страница 20: ...all conduit as required to the bottom access plate ONLY as seen in Figure 9 Siemens Airfield Solutions recommends removing the MAIN enclosure while drilling and attaching conduit to the BOTTOM access plate Make sure not to damage internal electronic components during installation of enclosure DO NOT blow out enclosures as metal shavings can damage the electronics Top Conduit and Cabling through bo...

Страница 21: ...A B A Terminal blocks TB1 and TB2 are system latching relay outputs that are used to control brightness steps of a CCR These output can also be configured to control any element that requires an ON OFF contact closure In addition these terminal blocks can be configured to control both CCR brightness steps and a L 847 X Circuit Selector Switch B Terminal blocks TB3 and TB4 accept any discrete conta...

Страница 22: ...6 7 8 A B C H Vault Computer RJ4 5 RJ45 CH A CH B Figure 11 ACE communications network generic wiring diagram For specific wiring diagrams of these connections please consult System External Wiring Diagrams which are included with ALCS system prints 2001 ADB Airfield Solutions LLC 96A0245D Page 18 All rights reserved Issued 5 01 ...

Страница 23: ...dication If all of the boards have power refer to the Processor board LED description table Table 1 for normal operation of each of the LEDs If any of the LEDs are not functioning as described in the table cycle ACE power and recheck If problem still occurs contact your Siemens Airfield Solutions service representative Channel A LED not Flashing Cycle power to the ACE unit If the problem still per...

Страница 24: ...also form binary error codes These codes are used by Siemens Airfield Solutions to determine board level problems Circuit Board Label LED description Normal working operation D10 Processor board Power Always on D6 Internal Processor Board Diagnostics Flashing D7 Internal Processor Board Diagnostics Flashing D8 Only used for error codes Off D9 Only used for error codes Off D2 Local Debug Communicat...

Страница 25: ...ll as its dimensions and other characteristics when appropriate Indentions show the relationships between assemblies subassemblies and parts The Part Number column gives the Siemens Airfield Solutions part number Item Description Part Number Quantity Note S1 Assembly xxxxxxxx 1 A NS Part xxxxxxxx 1 H1 Part or Assembly Part Assembly for option 1 xxxxxxxx 2 Part Assembly for option 2 xxxxxxxx 2 T1 A...

Страница 26: ...losure Part Numbers ACE Part Numbering System Display Board 0 With Display Board 1 Without Display Board Input Power Monitoring 0 Without Input Power Monitoring 1 With Input Power Monitoring Field Circuit Monitoring 0 No Field Circuit Monitoring 1 Monitors 1 Field Circuit 2 Monitors 2 Field Circuits 3 Monitors 3 Field Circuits 4 Monitors 4 Field Circuits 5 Monitors 5 Field Circuits 6 Monitors 6 Fi...

Страница 27: ...d 1 Without Display Board Input Power Monitoring 0 Without Input Power Monitoring 1 With Input Power Monitoring Field Circuit Monitoring 0 No Field Circuit Monitoring 1 Monitors 1 Field Circuit 2 Monitors 2 Field Circuits 3 Monitors 3 Field Circuits 4 Monitors 4 Field Circuits 5 Monitors 5 Field Circuits 6 Monitors 6 Field Circuits 7 Monitors 7 Field Circuits 8 Monitors 8 Field Circuits I O PCB As...

Страница 28: ... Basic ACE wall mount unit including XX X ranges from 01 to 09 number of field circuits to monitor current and voltage and number of field circuits to monitor Insulation Resistance Table 2 Complete ACE assembly part numbers Siemens Airfield Solutions Part Number Part Description 44A4801 ACE Processor Printed Circuit Board 44A4800 ACE Input Output Printed Circuit Board 44A4850 ACE Power Supply Prin...

Отзывы: