Figure 10: Fixture facing down
Figure 11: Tightening screws
7. Check the light fixture for water-tightness.
Note
Refer to
Checking the light fixture for watertightness
section for more information.
6.4.4 Checking the light fixture for watertightness
NOTICE
If maintenance is carried out in a workshop, check the watertightness of the light.
Preparation
1. Remove the watertightness test valve cap.
2. Fill up the light fixture with compressed air (test pressure = 130 kPa).
Test
1. Put the light fixture in water, wait 3 minutes and check if air leaks out of the light.
a. If air leaks out of the light fixture (between bottom cover and top plate or between prism and top plate or
watertightness valve and top plate), the light fixture is not watertight and must be repaired. Release the air from the
light. Disassemble the light fixture and re-check the mating surfaces and gaskets. Assemble the light fixture and
perform the watertightness test again.
b. If the light fixture is watertight, release the compressed air from the light fixture and assemble the cap on the test
valve.
2. The light fixture is ready to be reinstalled in the field.
WARNING
Never exceed pressure of 150 kPa inside the light fixture as this may lead to personal injuries and damage the light.
UM-5027, Rev. 1.0, 2020/12/10
33
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE
Страница 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 76: ......