4.0 Maintenance and Repair
To keep the Reliance Steady Burning LED Obstruction Light L-810 obstruction light fixtures operating efficiently, follow a
preventive maintenance schedule. Refer to
Table 3: L-810 Obstruction Light Fixture Maintenance
Interval
Maintenance Task
Action
Daily
Check visually for failure.
Replace the LED or Power Module if necessary.
Note
During replacement, clean lens and
check all wiring for defects.
Annually
When obstruction lights are mounted on disconnect
hangers, check lowering devices.
Clean and lubricate all lowering devices such as wire
guides, pulleys, all fittings, supports, and cables.
Clean the contact surfaces of the electrical disconnect.
96A0476, Rev. F, 2019/12/12
13
Copyright
©
ADB Safegate, All Rights Reserved