Note
Make sure that light fixtures with only one LED-cable is connected to the LED B-channel.
Figure 23: Converter with 1 connector
Figure 24: Converter with 2 connectors
3. Assemble the light fixture.
6.2.6 Reset the Fail Open converter 2.3
Open
1. Disconnect and disassemble the light fixture.
2. Make sure you have a 2-way electrical shunt/jumper (2.54 mm/0.100
‑
inch spacing), see
.
Figure 25: 2-way electrical shunt/jumper
Reset
1. Locate the 3-pin reset connector(s) on the converter. For the two-connector converter, there is one reset connector for
each side.
2. Place the 2-way electrical shunt (2.54 mm spacing) over the two pins marked red, see
.
Figure 26: Converter with 1 connector
Figure 27: Converter with 2 connectors
3. Close the light fixture and connect it to a CCR.
UM-0210, Rev. 2.0, 2020/04/30
33
Copyright
©
ADB Safegate, All Rights Reserved
Содержание RELIANCE AC
Страница 2: ......
Страница 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Страница 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Страница 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Страница 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Страница 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Страница 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Страница 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Страница 56: ......