© ADB SAFEGATE All Rights Reserved
17
2.3.6 Replacing an AGLAS Remote
Step 1:
In each case, inspect the technical condition of the AGLAS Remote which has to be removed or replaced, or the AGLAS Remote
which is to be installed as a replacement device.
Step 2:
If the old remote is still communicating with the master (can be verified with the AGLAS Configuration software), it is
recommended to logout this remote prior to removal.
Follow the “Logout procedure” procedure as described in “96A0430 AGLAS Configuration Software - User Manual”.
If the remote is completely dead, Step 2 is not applicable.
Step 3:
Switch off and disconnect the associated series circuit from the incoming power by removing the fuses of the Constant Current
Regulator (CCR).
Step 4:
Pull out the cut-out for the series circuit, if possible ground the series circuit and wait about 5 minutes until the circuit is fully
discharged.
Step 5:
Removing a AGLAS Remote
: first, separate the series circuit connections
X3
and
X1
and, in the case of the dual AGLAS Remote,
X4
at the cable plug connections. Then, open the ground connection
X2
by unscrewing the earth ground screw.
Step 6:
Installing a AGLAS Remote
: install the new AGLAS Remote according to the “Installation” on page 13.
Step 7:
Switch on the associated series circuit and verify if the replaced remote connected lamp(s) are functioning
(for RGL remotes: blinking).
Step 8:
Follow the “change remote” procedure as described in “96A0430 AGLAS Configuration Software - User Manual” to make the
replaced remote operational.