background image

 A

LPHA 

4000 RBG MNS, P

O

E I

NSTALLATION 

M

ANUAL 

(PN 1776610301 R

EV

. A)

1-1

Alpha 4000 RBG MNS PoE

Installation Manual

Alpha 4000 RGB MNS Series B

Содержание Alpha 4000 RGB MNS B Series

Страница 1: ...ALPHA 4000 RBG MNS POE INSTALLATION MANUAL PN 1776610301 REV A 1 1 Alpha 4000 RBG MNS PoE Installation Manual Alpha 4000 RGB MNS Series B ...

Страница 2: ...stems LLC All rights reserved Adaptive Micro Systems 7840 North 86th Street Milwaukee WI 53224 USA 414 357 2020 414 357 2029 fax http www adaptivedisplays com Adaptive is a registered trademark of Adaptive Micro Systems All other brand and product names are trademarks or registered trademarks of their respective companies ...

Страница 3: ... 5 Installation 1 5 Alpha 4000RGB 24 PRI MNS O Series B 1 5 Alpha 4000RGB PoE MNS O Series B 1 7 RS485 connection optional 1 8 Sign specifications 1 10 Wall mounting kit 1 11 Ceiling mounting kit optional 1 11 Back to back ceiling mounting kit optional 1 12 Cantilever mounting kit optional 1 13 Start up 1 14 Maintenance 1 15 Routine cleaning 1 15 Service and repair 1 15 1 INTRODUCTION 2 INSTALLATI...

Страница 4: ...temperature falls below the auto dimming threshold level then auto dimming stops and the LED brightness returns to normal level Item Name Description Item Name Description A CEILING MOUNT ATTACHMENT POINTS Optional ceiling mount not included Attach hanging brackets here optional E REAR ACCESS PANEL SCREWS 6 32 tamper proof screws Removable with a T15 pin torx driver not included B MICRO SD CARD AC...

Страница 5: ...0 C and 50 C 22 and 122 F Should only be used in an environment where the humidity non condensing does not exceed 95 Must be installed with at least 1 in 2 5 cm clearance on each end of the case and at least 2 in 5 1 cm clearance above the case Warranty will be voided by any form of misuse of abuse of the product Reducing electrical noise Adaptive recommends the following to decrease the amount of...

Страница 6: ...Positive to V in and Negative Ground to V in Negative Ground For the 24VDC connection a wire gauge of 28AWG minimum to 12AWG maximum is required torque 24VDC connection terminal points to a maximum of 7 lb in Attach the provided ferrite around the nominal 24VDC Positive and Negative Ground wiring ferrite must be attached within the sign Chassis terminal on sign to be connected to earth ground RS48...

Страница 7: ...moving either knockout so as to avoid the knockout blank unintentionally entering the inside of the unit No other entry holes may be added to the sign or warranty will be voided Ethernet wiring conduit conduit fittings for making connections to rear of LED sign are not supplied Use appropriate conduit fittings and connections to route Ethernet wiring into the LED sign termination compartment One i...

Страница 8: ... cord grip and locknut is provided as an alternative to using conduit 3 Wiring method shall be in accordance with In Canada CSA C22 1 Canadian Electrical Code Part I Safety Standard for Electrical Installations Section 32 In the United States the National Electrical Code NFPA 70 and the National Fire Alarm and signaling Code NFPA 72 4 If not done so already make the minimum customer PoE power conn...

Страница 9: ...ALPHA 4000 RBG MNS POE INSTALLATION MANUAL PN 1776610301 REV A 1 9 Alpha 4000 RBG MNS PoE INSTALLATION ...

Страница 10: ...5W max 4120 PoE 0 3 in 7 6 mm 16 120 37 2 x 3 2 x 7 4 in 94 5 x 8 1 x 18 8 cm 11 lb 5 0 kg Type 3 4PPoE per IEEE 802 3 bt 35W max 4160 PoE 0 3 in 7 6 mm 16 160 49 2 x 3 2 x 7 4 in 126 7 x 8 1x 18 8 cm 14 lb 6 4 kg Type 3 4PPoE per IEEE 802 3bt at 45W max 4080 24 PRI 0 3 in 7 6 mm 16 80 25 2 x 3 2 x 7 4 in 64 0 x 8 1x 18 8 cm 8 lb 3 6 kg 16 33VDC 1 8A max 16VDC 29W max 4120 24 PRI 0 3 in 7 6 mm 16 ...

Страница 11: ... four times the weight of the sign Guidelines This kit will include two ceiling mounting brackets A which will be attached to the units via four 6 32 screws B This kit will allow the customer to hang the sign with the appropriate braided wire or chain or rope etc The mounting wire chain will not be provided with this kit at this time The maximum weight of the 4160 unit is approximately 14 pounds H...

Страница 12: ...raided wire or chain or rope etc The mounting wire chain will not be provided with this kit at this time The maximum weight of two 4160 units is approximately 29 pounds The hardware for attaching to the mounting surface must be rated for the mounting surface Do NOT install directly to drywall plasterboard or other fragile supports Hardware for attaching to the mounting surface including hanging ch...

Страница 13: ... two or four 6 32 thumb screws C these components will be used to attach the sign to the mounting arm as well as keep it in place The mounting arm is a welded assembly using 12 gauge 1046 thick cold rolled steel while the cover is 050 thick aluminum with bendable wings to accommodate either one or two signs The maximum weight of two 4080 units is approximately 17 pounds The hardware for attaching ...

Страница 14: ...erial Number JY00000000 AMS Product serial number Serial Address V 01 Alpha Protocol Type code character serial address in hexadecimal Serial 9600 8N1 Serial baud rate data bits parity stop bits IP 10 11 11 254 Current IP address of sign default will be listed on the sign SUBNET 255 255 0 0 Current SUBNET of sign default will be listed on the sign Gateway 0 0 0 0 Current Gateway of sign default wi...

Страница 15: ...cable before disconnecting the power cord Routine cleaning Use only a soft lint free cotton cloth to clean the sign Do not use soap and water alcohol cleaners with alcohol or any other strong solvent Service and Repair There are no user serviceable parts in this sign Contact Adaptive Displays for service and repair information Sign display Meaning LNXv1 5 7 10 11 11 254 Operating system type and v...

Страница 16: ...PART NUMBER 1776610301 REV A Adaptive Display Systems 7840 North 86th Street Milwaukee WI 53224 USA 414 357 2020 www AdaptiveDisplays com ...

Отзывы: