4-7
Environmental Monitoring
The Bicolor LED on the the disk drives only flashes Red when a disk drive is
present and bypassed, or present and the Fibre Channel loop has failed. The
bicolor LEDs on the disk drive carrier will not flash Red if a disk drive is not
present. If the drive is not communicating on one loop and the other loop has
failed then the LED will flash intermittently between Red and Green.
Power Supply Carrier LEDs
The power supply (both AC and DC) for the disk drive shelf has two LED indica-
tors (see Figure 4-6)
Figure 4-6. LEDs on power supply carrier
These power supply status LEDs function as follows:
•
The green LED on the top is the power supply status indicator. This LED is
driven by the power supply.
•
The Red LED on the bottom is the power supply failure LED. It is normally
off. If a failure has occurred, this LED turns on steadily or flashes at regular
intervals. This LED is driven by the VEM. See Table 4-2 for the meaning of
the LED patterns.
Power Supply Failure LED (RED)
Power Supply Status LED (GREEN)
110/220V
Содержание RAIDStation RS/7F
Страница 1: ...RAIDstationTM RS 7F KIT Fibre Channel Storage Arrays January 2001 DO 1016 001 ...
Страница 2: ......
Страница 15: ...1 5 Introduction Figure 1 4 AC Power Supply Unit 1 1 0 2 2 0 ...
Страница 16: ...1 6 Introduction ...
Страница 24: ...2 8 Unpacking and Initial Setup ...
Страница 50: ...5 8 Removing and Installing Components ...