Appendix H: Technical Specifications
●
127
Environmental Specifications
Note:
With a Battery Backup Unit (BBU), the ambient temperature should not exceed 40 °C
Note:
Forced airflow is recommended.
DC Power Requirements
Current Requirements
Ambient temperature without forced airflow
0 °C to 40 °
C
Ambient temperature with forced airflow
0 °C to 55 °
C
Relative humidity
10% to 90%
,
noncondensing
Altitude
Up to 3,000 meters
Bus Type
Description
Requirements
PCIe
Ripple and noise
50 mV peak-to-peak (max)
PCIe
DC Voltage
3.3 V ± 9%, 12 V ± 8%
Adaptec Model
Typical Current
Adaptec RAID 5085
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5805
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5405
0.45A @ 3.3VDC; 0.94A @ 12.0VDC
Adaptec RAID 5445
0.45A @ 3.3VDC; 1.0A @ 12.0VDC
Adaptec RAID 5805Z
0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC
Adaptec RAID 5405Z
0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC
Adaptec RAID 5445Z
0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC
Adaptec RAID 51245
0.47A @ 3.3VDC; 1.68A @ 12.0VDC
Adaptec RAID 51645
0.47A @ 3.3VDC; 1.72A @ 12.0VDC
Adaptec RAID 52445
0.47A @ 3.3VDC; 1.78A @ 12.0VDC
Adaptec RAID 2045
0.43A @ 3.3VDC; 0.83A @ 12.0VDC
Adaptec RAID 2405
0.43A @ 3.3VDC; 0.83A @ 12.0VDC