background image

11

Quick Reference: Array Software
Part Number: 510893-00, Rev. B
Print Spec Number: 493983-00
Current Date: 3/1/99

ECN Date: 3/19/96

Menu Trees

The following diagrams show the arrangement of 
menu options for the Adaptec Initial Array Configu-
ration Utility, the Adaptec Array Driver Copy Util-
ity, and the Administrator Utility.

6

SYSTEM MENU*

Display Array

Change Array

Select Target

Array

Configuration

Status

- Display Array

- Display Array

 Drive Status

 Overview

- Add an Array

- Add Spare

Drive(s)

- Redefine

an Array

- Change Message

Repeat Cycle

- Change Broad-

cast Mode

- De-install

Array NLMs

- Delete

an Array

Administrator Utility

- Adaptec

Array #1

- Adaptec

Array #2

- Adaptec

Array #3

- Adaptec

Array #4

Install Utility

Suite

MAIN MENU

Replace Array

Display

Arrays

Drive

Adaptec Initial Array Configuration Utility

- Adaptec

Array #1

- Adaptec

Array #2

- Adaptec

Array #3

- Adaptec

Array #4

Initialize

Array

Add New

Array

- Adaptec

Array #1

- Adaptec

Array #2

- Adaptec

Array #3

- Adaptec

Array #4

Delete

Array

- Adaptec

Array #1

- Adaptec

Array #2

- Adaptec

Array #3

- Adaptec

Array #4

INSTALL SOFTWARE DRIVERS MENU

CD-ROM Drivers

Adaptec Array Driver Copy Utility

NetWare 3.xx Drivers

NetWare 4.xx Drivers

- Adaptec

Array #1

- Adaptec

Array #2

- Adaptec

Array #3

- Adaptec

Array #4

- Adaptec

Array #1

- Adaptec

Array #2

- Adaptec

Array #3

- Adaptec

Array #4

* If you are in Setup mode, a Format/Initialize Array

option also appears on the System menu.

Содержание AHA-398 Series

Страница 1: ...985 Driv ers and RAID Utilities disks included with each AHA 398x adapter We recommend that you use the Adaptec Initial Array Configuration Utility to create the first array on a new server only if yo...

Страница 2: ...ay The Selection List menu appears 5 Press Enter to define Array 1 6 Select the array type e g Mirrored If you select RAID5 or RAID0 a prompt asks if you want to make the array convertible between RAI...

Страница 3: ...u are prompted select a formatting method to initialize the new array Low level format is a lengthy process that writes a consistent pattern to the disks and checks the disk surface for defects Initia...

Страница 4: ...Administrator Utility This section describes the most frequently used options in the Administrator Utility For complete information on all options see the AHA 3980 3980W 3985 3985W User s Guide Starti...

Страница 5: ...ough 14 in Initial Array Configu ration Utility on page 2 4 When you have finished defining arrays and you are back at the Selection List menu press Esc Displaying Array Information To view logical an...

Страница 6: ...tine verifications see Scheduling Tasks on page 8 Reconstructing Data Follow these steps to reconstruct data on a replace ment disk if a disk fails in a mirrored or RAID 5 array and no spare disk is a...

Страница 7: ...removes a second disk when one has already been removed To reactivate an off line array 1 Physically correct the problem that caused the array to go off line 2 From the Main menu for the array select...

Страница 8: ...page 6 3 Select one of these options Schedule Task to Run Once To schedule the task for a single time Schedule Cyclic Task To schedule the task to run at regular intervals If you select this option th...

Страница 9: ...r 5 When you have finished selecting spares press Esc 6 When prompted type y to accept the new spare disks or n to reselect the disks You need not reformat the array Deleting a Spare Disk To delete a...

Страница 10: ...s 1 From the Main menu for the array select Convert RAID Level 2 Select Convert to RAID0 CVT or Convert to RAID5 CVT 3 Indicate the priority by typing a number from 0 through 9 0 assigns the lowest pr...

Страница 11: ...an Array Administrator Utility Adaptec Array 1 Adaptec Array 2 Adaptec Array 3 Adaptec Array 4 Install Utility Suite MAIN MENU Replace Array Display Arrays Drive Adaptec Initial Array Configuration Ut...

Страница 12: ...nt Data Values Start Verify Change Abort Verify Priority Re mirror Re mirror All Abort Change Priority RAID5 Reconstruct Single Drive DOWN Drives RAID0 RAID5 Mirror Reconstruct Convert to RAID 0 CVT C...

Страница 13: ...c com and ftp adaptec com To access the Adaptec forum on CompuServe 24 hours a day 7 days a week type GO ADAPTEC The Adaptec BBS provides answers to commonly asked questions and information on softwar...

Страница 14: ...ay Software Part Number 510893 00 Rev B Print Spec Number 493983 00 Current Date 3 1 99 ECN Date 3 19 96 AHA 3980 3980W AHA 3985 3985W MultiChannel PCI to SCSI RAID Adapters with SCSISelect Quick Refe...

Отзывы: