background image

3.

Thread  the  lead  power  cable  (red  +) under  the  doorstep  moulding  and  through  the  firewall.

 

WARNING

: Pass through  a grommet  in the firewall  to prevent  the  cable from  chaffing.  Attach the

 

ground  wire  (black  -

)  to  the  vehicle’s  frame  using  a  self

-tapping  screw.  Select  one  of  the  two

 

resetting breakers 

to match the client’s weight

:

-The 

8 amp breaker

 is for use when the combined weight of the client and chair is 

below 

200

 lbs

.

-The 

10 amp breaker

 is for use when the combined weight of the client and chair is 

above 

200

 lbs

.

-

The 

15 amp breaker

 is for use when the combined weight of the client and chair is 

above 250 lbs.

 

4. Connect  the  power  cable  (red+)  and  the  ground  cable  (black  -)  to  the  POWER-PULL  power  supply

cables coming out of the POWER-PULL box.

5. Install the plastic hook, part # 

PP710

. Secure the hook to the left hand side of the ramp, just above

the hinge. 

NOTE:

 FOR INSTALLATION ON AN IN-FLOOR RAMP, YOU WILL HAVE TO NOTCH OUT THE

EDGE OF THE SILL PLATE.