![Adamson IS119 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/adamson/is119/is119_user-manual_2846308007.webp)
Page 7
Adamson Systems Engineering | IS119 User Manual
When flown or stacked in the same array as an IS10, all IS119 presets contain the inherent delay needed to be properly
phase-aligned. When flown separately or ground stacked, IS119 subs should be phase-aligned to the IS10 array using
measurement software.
The Adamson LoadLibrary contains presets designed for 3 different IS119 deployments. Furthermore, there are
presets designed to pair with either the IS7 or the IS10. The below preset descriptions pertain to the standalone
subwoofer presets. For a master list, please refer the Adamson PLM & Lake Handbook, found on our website.
Subwoofer Configuration
Subwoofer Configuration
Applicable Preset
Page 7
Presets & Control
Alignment
Presets
IS119 32dB
All IS119 forward facing
Omni pattern
IS119 FB 32dB
Bottom IS119 forward facing,
top IS119 reversed
Cardioid pattern
IS119 FBF 32dB
Bottom and top IS119 forward
facing, middle IS119 reversed
Cardioid pattern
IS119 EF66 32dB
Two IS119 stacks, distance
from front grill to front grill of
66” (1.7m)
Cardioid pattern
Adamson Systems Engineering | IS119 User Manual