FREQUENTLY ASKED QUESTIONS / TROUBLESHOOTING

3.1.

Q: T

HE EXIT DEVICE WON

'

T UNLOCK WHEN

USE MY ACCESS CONTROL SYSTEM

A:

Check PS-LR board that MAIN POWER & OUTPUT POWER LEDs are on.

Check SW2 switch (located next to TRANSFORMER connector J5). Setting should be
on 120V. Disable Access Control from 1-2 of IN2 and/or 3-4 of IN1 found on J3 and
place a jumper wire in 3-4 of IN1. If exit devices activate, problem could be the access 
controller. Verify Jumper on J3 9-10 for Fire  Alarm is secure and tight. Verify connector
for BATT BACKUP is in place and secure. Also check for shorts in the wiring
and if fuses are blown in the PS-LR.

If existing hardware, check Solenoid for burnt and discolored tape. Measure Ohm readings
on Solenoid. Refer to 1.14 for solenoid value readings. Verify microswitch on solenoid is
normally closed. Switch becomes normally open when powered applied. Verify revision 
on Two Wire Driver Board. If lower than REV H, recommend replacement. Also check for 
shorts in the wiring and if fuses are blown in the PS-LR.

3.2.

Q: I 

HAVE BLOWN FUSES IN MY

PS-LR

A:

If new install. Check for shorts in the wiring, particularly around the exit device and 

hinge. Check for rods binding. 

If existing hardware, verify revision on Two Wire Driver Board. If lower than REV H. 
recommend replacement. Check Solenoid for burnt or discolor tape. Possible
plunger is binding in core. Measure Ohm readings on Solenoid. Refer to 1.14 for solenoid 
value readings. Replace PS-LR board if F3 is blown.

3.3.

Q: T

HE

E

XIT

D

EVICE INTERMITTENTLY LOCKS AND UNLOCKS

?

A:

When device is activated, the solenoid may do a "chatter" where the plunger is

released and then pulled back by the solenoid. Check microswitch on solenoid for loose 

terminals. Measure microswitch with Ohm Meter for continuity. Recommend replacing 

Two Wire Driver board and Solenoid if no trouble found on microswitch.

3.4.

Q: N

O POWER TO THE

S

OLENOID

.

A

: Check microswitch on solenoid for loose terminals. Measure microswitch with Ohm 

Meter for continuity. If meaused open, replace Microswitch. If terminals are loose, crimp terminal 
connec tors with needle nose pliers.

Before proceeding through the next section, ensure that exit device latches are not binding 
against their corresponding strikes. A bound latch can cause sluggish electric retraction or 
prevent retraction entirely.

Содержание PS-LR

Страница 1: ... C A 9 1 7 6 7 8 0 0 8 7 2 3 2 6 7 F a x 8 0 0 2 3 2 7 3 2 9 9 1 7 6 7 8 0 0 8 7 2 3 2 6 7 F a x 8 0 0 2 3 2 7 3 2 9 Page 1 of 10 Need more information Visit our website at www www adamsrite com adamsrite com Rev Date 07 26 10 80 0180 247 REV H OWNERS MANUAL AND INSTALLATION INSTRUCTIONS A AD DA AM MS S R RI IT TE E P PO OW WE ER R S SU UP PP PL LY Y P S L L R Document Part Number 80 0180 247 Rev ...

Страница 2: ...OWER SUPPLY ___________________________6 1 8 STEP 8 INSTALL BACKUP BATTERIES OPTIONAL ____________________________6 1 9 STEP 9 PS LR WIRING DIAGRAM __________________________________________7 1 10 STEP 10 BASICDOOR WIRING DIAGRAM____________________________________8 1 11 STEP 11 WIRE AUTOMATIC DOOR INTERFACE OPTIONAL 9 ___ 1 12 STEP 12 WIRING PRIMARY POWER CONNECTION 9 2 DESCRIPTIONS PART NUMBERS ...

Страница 3: ...evice remains unlatched until the controlling switch is released An optional mode is available allowing both retraction timers to activate in response to closure of either switch The Adams Rite Power Supply is listed as an Exit Device Access Control System unit to UL305 and UL1012 requirements for power supplies and CAN CSA C22 2 Exit devices under the system control remain latched during a comple...

Страница 4: ...dip switch SW1 Single Input Sequential Operation Factory Setting Application Control one opening Operation Either input retracts Exit Device 1 immediately followed by Exit Device 2 Dual input Independent Operation Application Control two separate openings Operation Input IN1 retracts Exit Device 1 Input IN2 retracts EXIT DEVICE 2 1 3 STEP 3 SET HOLD OPEN TIMES The Adams Rite Power Supply has two h...

Страница 5: ... alarm control connect as follows Remove the jumper wire factory installed between positions 9 and 10 Fire of the J3 terminal block Connect the fire alarm normally closed relay contacts to positions 9 and 10 Fire of the J3 terminal block Closed relay contacts indicate NO ALARM CONDITION When a fire alarm occurs the controlled exit devices will immediately latch secure Exit Devices remain latched d...

Страница 6: ...nd two 12V 7AH batteries such as EverOn EVA12 7 5F batteries or equivalent An orange jumper block has been installed into the BATT BACKUP connector of the Power Supply circuit board Remove this jumper by pulling the orange jumper free from the circuit board Install the Battery Backup System circuit board in the location shown below Mounting points are available in the enclosure for the Battery Bac...

Страница 7: ...as relay contacts that let the automatic door opener know the latch state The relay contacts are closed when the latch is fully retracted The relay contacts open when the latch is extended Connect the automatic door opener as shown in the figure below 1 12 STEP 12 WIRING PRIMARY POWER CONNECTION J4 Connection For the 115 230 VAC power input terminal block J4 will accommodate up to 12AWG wire Conne...

Страница 8: ...proximately 44 OHMS 28 5VDC when powered Black Red Wires 2 OHMS 6VDC when powered Microswitch Blue wires set on Normally Closed Can be measured from Two Wire Driver Board Solenoid wires do not need to be removed from board If Microswitch is Open when no power applied terminals may be set Normally Open Terminal Connectors are loose or Microswitch is failing and need replacing 2 3 PS LR VALUE READIN...

Страница 9: ...sed Switch becomes normally open when powered applied Verify revision on Two Wire Driver Board If lower than REV H recommend replacement Also check for shorts in the wiring and if fuses are blown in the PS LR 3 2 Q I HAVE BLOWN FUSES IN MY PS LR A If new install Check for shorts in the wiring particularly around the exit device and hinge Check for rods binding If existing hardware verify revision ...

Страница 10: ...rts There is no Fire Alarm connected between J3 9 and J3 10 or the factory installed jumper between J3 9 and J3 10 is removed IN1 AND IN2 LIGHTS DO NOT LIGHT IN RESPONSE TO INPUT SWITCHES An open connection in the field wiring exists between the Adams Rite Power Supply and control switch used for activating the latch solenoids A defective control switch exists on J3 1 and J3 2 or J3 3 and J3 4 OUT...

Страница 11: ...is in line with the transformer output 28VDC Little Fuse P N 213004 MXP Adams Rite Mfg P N 29 0667 F2 3 15A 250V 5X20MM 202 I2 t SLOW BLOW Fuse F2 is in line with the transformer input 120VAC 230VAC Little Fuse P N 2133 15 MXP Adams Rite Mfg P N 29 0668 BBK LR FUSES BBK LR BATTERY BACKUP CHARGER FUSE IS THE SAME AS F1 ABOVE FUSE REPLACEMENT MUST BE THE SAME RATING Fuse F3 is not user serviceable I...

Страница 12: ...0 2 3 2 7 3 2 9 4 2 Connector Signal Descriptions 4 2 1 Connector J1 BATTERY BACKUP PIN DESCRIPTION 1 Power In 28VDC returned from battery charging system 2 Power Out 28VDC supplied to battery charging system 3 Ground 4 2 2 Connector J3 FIELD WIRING PIN DESCRIPTION 1 2 INPUT 2 Normally open activation switch 3 4 INPUT 1 Normally open activation switch 5 EXIT DEVICE 2 Coil return 6 EXIT DEVICE 2 28...

Отзывы: