background image

© Adam Equipment Company 2018

 

 

1

 

 

CONTENT 

P.N. 3036614279, Revision A, June 2018

 

 
 
 

1.0

 

INTRODUCTION ....................................................................................................... 2

 

2.0

 

SPECIFICATIONS ..................................................................................................... 3

 

3.0

 

INSTALLATION ......................................................................................................... 5

 

3.1

 

UNPACKING ......................................................................................................... 5

 

3.2

 

LOCATING ............................................................................................................ 5

 

3.3

 

SETTING UP ......................................................................................................... 6

 

4.0

 

KEYPAD .................................................................................................................... 7

 

4.1

 

NUMERIC ENTRY METHOD ................................................................................ 7

 

5.0

 

DISPLAY .................................................................................................................... 8

 

6.0

 

SYMBOLS AND INDICATORS .................................................................................. 8

 

7.0

 

BATTERY OPERATION ............................................................................................ 8

 

8.0

 

DISPLAY BRIGHTNESS ............................................................................................ 9

 

9.0

 

AUTO POWER OFF .................................................................................................. 9

 

10.0

 

 OPERATIONS ..................................................................................................... 10

 

10.1

 

ZEROING ............................................................................................................ 10

 

10.2

 

TARING ............................................................................................................... 10

 

10.3

 

WEIGHING .......................................................................................................... 10

 

10.4

 

CHECK-WEIGHING ............................................................................................ 11

 

10.5 

 

LIMITS STORED IN MEMORY ........................................................................... 12

 

11.0

 

CALIBRATION ...................................................................................................... 12

 

12.0

 

PARAMETER SETTING ....................................................................................... 13

 

13.1 

 

CHECK WEIGHING PARAMETERS ................................................................... 13

 

13.2  

 

SCALE PARAMETERS ....................................................................................... 14

 

14.0

 

ERROR CODES ................................................................................................... 15

 

14.0

 

REPLACEMENT PARTS AND ACCESSORIES ................................................... 16

 

15.0

 

SERVICE INFORMATION .................................................................................... 16

 

16.0

 

WARRANTY INFORMATION ............................................................................... 17

 

 

 

 

 

Содержание WBW 16 L

Страница 1: ...Adam Equipment Company 2018 Adam Equipment WBW L Software revision U 4 01...

Страница 2: ...SYMBOLS AND INDICATORS 8 7 0 BATTERY OPERATION 8 8 0 DISPLAY BRIGHTNESS 9 9 0 AUTO POWER OFF 9 10 0 OPERATIONS 10 10 1 ZEROING 10 10 2 TARING 10 10 3 WEIGHING 10 10 4 CHECK WEIGHING 11 10 5 LIMITS STO...

Страница 3: ...steel weighing platforms on an ABS plastic base assembly which is sealed to IP 65 making it water proof All scales have sealed keypads with colour coded membrane switches and the displays are clear re...

Страница 4: ...ity S D 0 2 g 0 5 g 1 g 2 g Linearity 0 4 g 1 g 2 g 4 g Pounds Maximum Capacity 5 lb 9 lb 18 lb 35 lb Tare Range 5 lb 9 lb 18 lb 35 lb Readability 0 0005 lb 0 001 lb 0 002 lb 0 005 lb Repeatability S...

Страница 5: ...ugh an external Power Supply Module Battery Internal rechargeable battery 50 hours operation Calibration Automatic External Display Digit LED display with indication of functions Scale Housing IP 65 S...

Страница 6: ...duce the accuracy Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable p...

Страница 7: ...le in the spirit level is in the centre of the level and the scale is supported by all four feet Attach the power supply module to the bottom of the scale and plug into the mains Press the O I key to...

Страница 8: ...and shows the results This is the net weight Enters the selected parameter or value for setting Unit Selects the weighing units from a preset list of available units Shifts the flashing digit to the n...

Страница 9: ...isplay to the left there are three LED s that indicates when the weight is below within or over the pre set limits during check weighing Weight LED Below the low limit Red Within the limits Green Abov...

Страница 10: ...r the internal battery will be charged If the LED is green the battery is being charged If it is red it is nearly discharged and yellow indicates the battery is increasing the charge level Continue to...

Страница 11: ...The stable and Net indicator will be on As a product is added only the weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the fir...

Страница 12: ...other than 0000 See the parameter F4PS in section 12 1 Enter the correct password using the numeric entry method as mentioned in section 4 1 If the password is 0000 it will display the last used high...

Страница 13: ...weighing unit selected is either pounds ounces or pounds ounces Method To start the calibration turn the scale off and then turn it on again Press Tare during the self test Scale will show P Enter cod...

Страница 14: ...ned in section 4 1 If the password is 0000 it will go directly to F1 LLK Parameter Description Options Default setting F1 LLt Limit Lock will prevent a normal user from changing the check weighing lim...

Страница 15: ...e or disable weighing units will not allow to disable all units at least one has to be enabled Press enter to scroll through units to set kg g lb oz lb oz kg S2 bL Display brightness settings Br 1 Br...

Страница 16: ...e scale on Excessive weight on the pan when zeroing the scale Platform is not installed Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 A D count is not correct when turn...

Страница 17: ...eady A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be av...

Страница 18: ...nal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performanc...

Страница 19: ...ercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Страница 20: ...49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 974 9745 F...