Страница 2: ...Adam Equipment Company 2008...

Страница 3: ...N KILOGRAM TO POUND 11 5 9 HOLD FUNCTION ANIMAL WEIGHING 11 5 10 COUNT OPERATION 11 5 11 HIGH RESOLUTION DISPLAY 12 6 0 BATTERY OPERATION 13 6 1 BATTERY CAPACITY 13 6 2 BATTERY CHARGE PROMPT 13 6 3 OV...

Страница 4: ...Adam Equipment Company 2008 2...

Страница 5: ...the following standard features Lightweight for ease of handling Supplied complete with the AE 202 Indicator in plastic housing Precision load cells for accurate weighing results every time Handles fo...

Страница 6: ...cumulation facility Selectable automatic power off Bi directional RS 232 Interface Operation from internal rechargeable battery or main power Lockable keyboard calibration and configuration for securi...

Страница 7: ...ad acid battery charged by internal power supply Interface Bi directional RS 232 Interface RS 232 Connector 9 Pin d sub miniature socket Display LED Calibration Lockable keyboard calibration Housing P...

Страница 8: ...ove the Indicator and the power supply adapter packed separately Place it on a level and firm floor Position the beams side by side Plug in the Indicator into the socket provided at the back of the pa...

Страница 9: ...ight Zero The scale is at zero Lb Show pounds as unit of weight The keys perform the following functions Zero Zero the display set the zero point or enter a tare value Tare Tare the balance x10 Inc Sh...

Страница 10: ...ry The value xx will vary from a low value of about 10 to a maximum of 99 To switch off the power press the On Off key again It may be necessary to hold the key a few seconds until display shows oFF W...

Страница 11: ...o select and the Kg lb Set key to enter your selection and return to normal weighing Note In automatic accumulation state the Auto indicator will be on 5 5 MANUAL MEMORY ACCUMULATION If the accumulati...

Страница 12: ...will show n 0 followed by zero weight If you wish to clear the memory press the Kg lb Set to view totals then Zero when the totals are being displayed key 5 7 ACCUMULATION VALUE DISPLAY PRINT AND CLEA...

Страница 13: ...the weight is increased or returns to zero The higher the value the stronger the filter will be for animal weighing applications To un Hold the display to continue weighing or return to zero you may...

Страница 14: ...e Kg lb Set is pressed directly the value shown will be based on the sample value set previously Press the On off key to enter weighing mode and the Count indicator will be switched off 5 11 HIGH RESO...

Страница 15: ...immediately 6 3 OVER DISCHARGE PROTECT When battery capacity is less than 10 the indicator will be switched off automatically to avoid battery over discharge 6 4 POWER SAVING MODE Auto power saving mo...

Страница 16: ...to the scale Wait for the stable indicator and press the Kg lb Set key After the calibration is complete the display will return to the normal weighing mode Note 1 If the zero point is correct and jus...

Страница 17: ...yed in the format F AbCdE The related functions are listed below Press Acc The first digit will start flashing Press the x10 Inc key to change the options 0 or 1 Press Acc to move to the next digit On...

Страница 18: ...TION PARAMETERS These set of parameters allow you to set the values for functions that control communicating with a PC or a printer via the RS 232 interface 8 2 1 COMMUNICATION ADDRESS The value as se...

Страница 19: ...to scroll through the other options 1200 2400 4800 9600 Select the desired setting by pressing Kg lb Set and move to the last parameter for viewing the A D Count 8 2 3 A D COUNT Press Acc to show the...

Страница 20: ...F Send Total of accumulator C CR LF Clear Totals of accumulator Z CR LF Zero Tare the scale OUTPUT FORMATS n item number w the weight u units Continuous output 14 ASCII Characters leading zeros are sp...

Страница 21: ...lf lf lf lf I e cr lf n _ _ _ 6 cr lf t o t a l _ _ 6 2 5 K G cr lf lf lf lf lf 10 0 LOAD CELL CONNECTION Load cell supply voltage 5 VDC Pin 1 2 E Load cell excitation positive Pin 4 5 E Load cell exc...

Страница 22: ...dead load is applied Err 5 Range calibration has failed Check that load cell is wired correctly and is the correct size and output for scale Ensure that correct mass was loaded Err 6 Weighing value ca...

Страница 23: ...er methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and kee...

Страница 24: ...Adam Equipment Company 2008 22...

Страница 25: ...ease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warra...

Страница 26: ...Adam Equipment Company 2008 24...

Страница 27: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...