background image

POS.  

DESCRIPTION 

REFERENCE 

 

QTY

 

 

230 Volts 

115 Volts 

STATOR MEC 63 

232204000000 

71009023   

1

JUNCTION BOX SEAL 63/71-2 

10501000000 

 

1

CAPACITOR HOLDER Ø 10 

140250100000 

 

1

SCREW Ø 3,5  X 13  

80801215000 

 

10

CABLE FITTING 

140250300000 

 

1

SPACER WASHER Ø 4  

80301400000 

 

1

SCREW M4 X 8  

82301410100 

 

1

SWITCH 22 X 30 

190050210000 

 

1

SPADE CONNECTOR COVER 6,3 

190110000000 

 

6

10 

JUNCTION BOX SEAL FKL 71 

10502000000 

 

1

11 

CAPACITOR CLIPS  

140250200000 

 

1

12 

BEARING 6201 2RS 

101001600000 

 

2

13 

SHAFT ROTOR MEC 63 

6290150000L 

 

1

14 

SPRING WASHER Ø 32 

84500000000 

 

1

15 

FAN FLANGE MEC 63 

15501600000X 

 

1

16 

HOUSING BOLT M5 X 125 

61004600000 

 

4

17 

FAN MEC 63 WITH METAL RING Ø12 

140250400000 

 

1

18 

FAN COVER MEC 63 

140250500000 

 

1

19 

ELECTRIC BLACK CABLE  

190200000000 

190000190000 

1

20 

CAPACITOR  

190060000000 

190061000000 

1

21 

FLANGE 

61715000000 

61715000000 

1

22 

BY-PASS VALVE 

71000520 

71000520 

1

23 

PUMP HOUSING 60 LT 1”/ 1” 

71000036 

71000036 

1

24 

BY-PASS SPRING 

16001005 

16001005 

1

25 

BY-PASS CAP 

71000521 

71000521 

1

26 

O-RING 3118 

18001008 

18001008 

1

27 

METAL CAP 1”  

17001094 

17001094 

1

28 

SMALL PUMP FILTER 

41140000 

41140000 

1

29 

O-RING 132 

11010200400 

11010200400 

1

30 

METAL CAP 3/4”  

17001006 

17001006 

1

31 

“FILTER” STICKER 

71000587 

71000587 

1

32 

“CLEAN FILTER” STICKER 

71000546 

71000546 

1

33 

O-RING 2212 

18001014 

18001014 

1

34 

FLANGE PIN Ø4 X 14 

91214140000 

91214140000 

1

35 

ROTARY SEAL 10196 

12010031000 

12010031000 

1

36 

SHAFT KEY 3 X 3 X 15 

17001097 

17001097 

1

37 

PUMP ROTOR Ø45 

61000003 

61000003 

1

38 

VANE 

71000522 

71000522 

5

39 

SCREW M5 X 45 

13001002 

13001002 

3

40 

PLASTIC CAP Ø31 

163013500000 

163013500000 

2

41 

“DANGER” STICKER 

71000653 

71000653 

1

42 

“CE” STICKER 

220000000000 

220000000000 

2

4. WARNING SIGNS

4.1 LABEL INDICATING THE DANGER

5. LIST OF PARTS

3.2 MECHANICAL RISKS

Parts subjected to wear:

•  The vanes.
•  The bearings.
•  The rotor.

These  parts  should  be  replaced  with  original  spare  parts  by 
qualified personnel at authorized service centers.

3.3 MACHINE TECHNICAL DATA CHART

Motor constructive features:

Closed self - ventilated two poles motor with IP
55 protection, insulation class F.

Pump constructive features:

Pump body: G 25 CAST IRON
Motor rest: G 25 CAST IRON
Impeller: SINTERED IRON
Motor shaft: INOX STEEL

3.4  FLOW METER CALIBRATION

Calibration is required when the meter is new, after disassembly, 
when metering a different fluid, or after significant wear.
A  proving  container  or  a  container  of  KNOWN  volume  will  be 
needed for the calibration procedure. It is recommended that the 
container volume be at least 19 litres (5 gallons).

Procedure for calibration   

1. Fill container to a know volume.
2. If indicated amount on the flow meter does not match know vol- 
  ume,  calibration  is  required.  Insure  pump  power  is  off  and  sys- 

 BEWARE

IT IS FORBIDDEN TO CARRY OUT ANY JOB ON 

ELECTRICAL  EQUIPMENTS THAT ARE ON VOLTAGE

ANY DEPARTURE FROM INSTRUCTIONS, MUST BE AUTHORIZED 

BY THE PERSON IN CHARGE

IN CASE OF UNUSUAL DANGER, ANOTHER PERSON MUST BE PRESENT 

IN PLACE AS WELL AS WHO IS CARRYING OUT THE JOB

START WORKING IN ACCORDANCE WITH 

THE PRECAUTIONARY MEASURES, ONLY!

In compliance with DPR.547 connected with the prevention of accidents

 

ADAM PUMPS 

• PA1 60 • PA2 80-100 L • LIGHTPUMP 60-80-100 L • DRUM TECH 60-80-100 L • HI-TECH 60-80-100 L

5.1 ELECTRIC PUMP PA1 60

M

O

T

O

R

 1

1

5

V

POS.  

DESCRIPTION 

REFERENCE 

 

QTY

 

 

230 Volts 

115 Volts 

STATOR MEC 71 

64100000000 

71009025 

1

JUNCTION BOX SEAL 63/71-2 

10501000000 

 

1

CAPACITOR HOLDER Ø10 

140250100000 

 

1

SCREW Ø 3,5 X 13  

80801215000 

 

10

CABLE FITTING 

140250300000 

 

1

SPACER WASHER Ø4  

80301400000 

 

1

SCREW M4 X 8  

82301410100 

 

1

SWITCH 22 X 30 

190050210000 

 

1

SPADE CONNECTOR COVER 6,3 

190110000000 

 

6

10 

JUNCTION BOX SEAL FKL 71 

10502000000 

 

1

11 

BEARING 6202 2RS 

101001700000 

 

1

12 

BEARING 6204 2RS 

101001880000 

 

1

13 

SHAFT ROTOR MEC 71 

62901700000 

 

1

14 

SPRING WASHER Ø32 

84505000000 

 

1

15 

FAN FLANGE MEC 71 

15502600000X 

 

1

16 

HOUSING BOLT M5 X 125 

6100450000Z 

 

4

17 

FAN MEC 71 WITH METAL RING Ø14  140260400000 

 

1

18 

FAN COVER MEC 71 

140260500000 

 

1

19 

SHAFT KEY 6 X 6 X 20 

90505050000 

 

1

20 

CAPACITOR 

190061000000  

 

1

21 

ELECTRIC BLACK CABLE  

190200000000 

190000190000 

1

22 

BY-PASS VALVE 

71000520 

71000520 

1

23 

PUMP HOUSING 80 LT 1”/ 1” 

71000060 

71000060 

1

24 

BY-PASS SPRING 

16001005 

16001005 

1

25 

BY-PASS CAP 

71000521 

71000521 

1

26 

O-RING 3118 

18001008 

18001008 

1

27 

METAL CAP 1”  

17001094 

17001094 

1

28 

BIG PUMP FILTER 

41410000 

41410000  

1

29 

“FILTER” STICKER 

71000587 

71000587 

1

30 

“CLEAN FILTER” STICKER 

71000546 

71000546 

1

31 

O-RING 85 X 3 

18001022 

18001022 

1

32 

ROTARY SEAL 20307 

12001015020 

12001015020 

1

33 

PUMP ROTOR Ø72 

61000010 

61000010 

1

34 

VANE 

71000569 

71000569 

7

35 

PUMP COVER  

71000063 

71000063 

1

36 

SCREW M5 X 16 

13001007 

13001007 

4

37 

PLASTIC CAP Ø31 

163013500000 

163013500000  

2

38 

“DANGER” STICKER 

71000653 

71000653  

1

39 

“CE” STICKER 

220000000000 

220000000000 

1

5.2 ELECTRIC PUMP PA2 80

M

O

T

O

R

 1

1

5

V

  tem pressure relieved, then remove seal screw and turn calibra- 
  tion  screw  counter  clockwise  to  reduce  indicated  amount  or  
  clockwise to increase the amount. A full turn will change the indi- 
  cated amount by approximately 0.4L. Re-install seal screw. 
3.  Repeat step 2 until calibration is acceptable.

calibration procedure

Содержание PA1 60

Страница 1: ...60 PA2 80 100 L LIGHTPUMP 60 80 100 L DRUM TECH 60 80 100 L HI TECH 60 80 100 L ELECTRICPUMP LIGHTPUMP DRUM TECH HI TECH cabinets meter DC and AC pumps accessories repair kit USE AND MAINTENANCE MANU...

Страница 2: ...NOTE...

Страница 3: ...AM PUMPS Spa Via della Resistenza 48 41011 Campogalliano Modena Italy 2006 NOV Code 21075000000000 ELETTR PA 1 60 230 Volt 50 Hz imb Serial Number 180387 230 Volt 50 Hz IP 55 370W 2 5 A 2800 rpm Conde...

Страница 4: ...xtinguishing powders charged with CO2 only Extinguishers should be kept near the pump Combustion of paints and plastic parts may produce toxic emissions use the normal precautions in case of fire alwa...

Страница 5: ...ackage for damage and verify that the unit is not damaged Damage must be reported within 10 days of receiving the unit For correct unpacking carefully follow these instructions 1 Placed the case on th...

Страница 6: ...he container volume be at least 19 litres 5 gallons Procedure for calibration 1 Fill container to a know volume 2 If indicated amount on the flow meter does not match know vol ume calibration is requi...

Страница 7: ...0 41410000 1 7 O RING 3118 18001008 18001008 1 8 METAL CAP 1 17001094 17001094 1 9 FILTER STICKER 71000587 71000587 1 10 CLEAN FILTER STICKER 71000546 71000546 1 11 ROTARY SEAL 20307 12001015020 12001...

Страница 8: ...ling service and dispose in the correct manner This will allow the recycling of raw materials and help protect the environment 6 ADAM PUMPS PA1 60 PA2 80 100 L LIGHTPUMP 60 80 100 L DRUM TECH 60 80 10...

Отзывы: