background image

31 | 

P a g e    

© Adam Equipment Company 2010

 

 

7-7 Peel Off Sensor Threshold Level (Manual Setting)

 

Press Enter key, Same as 7-6 

 

 

 

 

 

 

 

 
Enter threshold level and press Enter 
key, levels 0 ~ 255 are available, 

 

 

 

 

 

 

7-8 Select Label Format

 

Press Enter key 

 

 

 

 

 

 

 

Select label format and press Enter 
key, refer to the APPENDIX 

 

 

 

 

 

 

 

7-9 Select Printing Item 
Press Enter key 

 

 

 

 

 

 

 

P7-7                                            83 

7. Peel Off Threshold 

P7-8                                            40 

  8. Select Label Format 

P7-8                                               

  8. Select Label Format 

P7-7                                       

7. Peel Off Threshold

 

P7-9 

  9. Select Printing Item 

Содержание NETS

Страница 1: ...1 P a g e Adam Equipment Company 2010 Adam Equipment NETS Price Computing Scale RevA May 2011 Specifications are subject to change without notice to improve ...

Страница 2: ...dths mm Paper Label printing 60 58 56 Available Labels mm 35 40 60 80 100 Label roll size mm Max φ120 1 200 labels at 40mm length Printing Speed mm 80 100 Speed PLU keys 60 PLU memory Standard Memory 0 5MB 1000 labels at 500 characters Extended Memory 1MB Numeric Displays digit Message Display LED Price 8 Weight 5 Unit price 7 LCD Graphic 256 x 32 pixels Platter size mm inch 415 16 3 x 260 10 2 Pr...

Страница 3: ...ong electromagnetic fields near by 4 Do not apply sudden impact to the platter 5 Always level the scale 6 Do not spill the water to the scale 7 Do not use cleaners which includes solvent or sinner 8 Scale should be calibrated by authorized person prior to being to used 9 Turn on the scale 10 minutes before using 3 3 P PR RE EC CA AU UT TI IO ON NS S 4 4 O OV VE ER RV VI IE EW WS S Cartridge ...

Страница 4: ...4 P a g e Adam Equipment Company 2010 Displays Key Board I O Connections RS 232C Network Option AC Connect Fuse Holder External Keyboard Option Cash Drawer Option Power Switch ...

Страница 5: ... or remove tare container weight after tare set scale displays net weight and the designator NET is turned on Auto key used to set scale to automatic printing mode scale prints automatically after weight stable the designator AUTO is turned on while this function is activated key works by toggle Save key used to save current PLU the designator SAVE is turned on while this function is activated key...

Страница 6: ...zero STABLE It indicates scale is stable NET It indicates tare has been set SHIFT It indicates shift function in PLU programming CAPS LOCK It indicates function of entering capital letter INS It indicates function of insertion COM It indicates scale is under communication AUTO It indicates automatic printing mode SAVE It indicates PLU saving mode SALE It indicates sale mode FUNC It indicates scale...

Страница 7: ...e not print out any label or ticket unless PLU has been programmed 1 1 S SE EL LL LI IN NG G B BY Y W WE EI IG GH HT T See Page 8 2 2 S SE EL LL LI IN NG G B BY Y C CO OU UN NT T See Page 9 3 3 P PR RI IC CE E A AD DD D U UP P See Page 10 4 4 M MU UL LT TI IP PL LE E L LA AB BE EL LS S See Page 11 8 8 S SE EL LL LI IN NG G M MO OD DE E ...

Страница 8: ... key indirect Put commodity Fillet on the platter and press PRINT key While the designator AUTO is turned on scale prints automatically Remove commodity on the platter While the designator SAVE is turned on scale saves current PLU 0 000 0 00 0 00 Enter PLU 1 200 5 90 7 08 FILLET 0 000 0 00 0 00 0 000 5 90 0 00 FILLET 1 1 S SE EL LL LI IN NG G B BY Y W WE EI IG GH HT T Enter PLU ...

Страница 9: ...ng one of SPEED key direct or by enter PLU number and press PLU key indirect Press FOR key Enter number of commodity Candy and PRINT key Weighing mode 0 000 0 00 0 00 Enter PLU 1 0 25 0 25 SWEET CANDY 50 0 25 12 50 SWEET CANDY 0 000 0 25 0 00 SWEET CANDY 0 000 0 00 0 00 Enter PLU ...

Страница 10: ... press PLU key indirect Put commodity Tenderloin on the platter and press ADD key Remove the commodity Tenderloin and enter another PLU Put the commodity Fillet on the platter 0 000 0 00 0 00 Enter PLU 1 000 7 99 7 99 ADD UP 0 000 5 90 0 00 FILLET 0 000 7 99 0 00 TENDERLOIN 1 200 5 90 7 08 FILLET 3 3 P PR RI IC CE E A AD DD D U UP P ...

Страница 11: ...y Weighing normal mode Multiple labels function is suppressed on Ticket Printing version Enter PLU by pressing one of SPEED key direct or by enter PLU number and press PLU key indirect Put commodity Apple on the platter and press X key 1 000 7 99 7 99 ADD UP 0 000 0 00 0 00 Enter PLU 0 000 0 00 0 00 Enter PLU 0 100 1 99 1 99 Multiply 0 X Price 0 00 0 100 1 99 1 99 APPLE 4 4 M MU UL LT TI IP PL LE ...

Страница 12: ...ompany 2010 Enter number of labels for example 5 Press PRINT key scale prints a label when each pressing PRINT key 0 100 1 99 9 95 Multiply 5 X Price 9 95 0 100 1 99 7 96 Number of Labels 4 X Price 9 95 0 000 0 00 0 00 Enter PLU ...

Страница 13: ...ey key key key key key key key key key key key key 1 1 E ED DI IT T P PL LU U Enter See Page 14 2 2 E ED DI IT T S SP PE EE ED D K KE EY Y Enter See Page 16 3 3 E ED DI IT T M MA AS ST TE ER R F FI IL LE ES S Enter See Page 16 4 4 E ED DI IT T D DA AT TE E T TI IM ME E Enter See Page 21 5 5 S SE EL LE EC CT T F FU UN NC CT TI IO ON N Enter See Page 21 6 6 A AC CC CO OU UN NT T Enter See Page 26 7 ...

Страница 14: ...odity press Enter key again to skip second line Enter group code and press Enter key numbers 0 99 are available Group codes are used to grouping PLUs by categories of commodities Enter UPC code and press Enter key numbers 0 999 999 are available UPC code is commodity code of bar code P1 1 1 PLU 1 PLU Type 1 By Weight 2 By Count P1 4 12345 PLU 4 UPC Code P1 3 20 PLU 3 Group Code P1 0 1 PLU 0 PLU No...

Страница 15: ...ter key at the each ingredient Max 56 characters x 10 lines are available ingredient can be printed at the label length 60 mm or longer Pressing SAVE key finishes edit PLU at the any entering of ingredient Repeat steps to enter another PLU or press ESC key to the next mode To return to the normal mode press SET key P1 5 3 95 PLU 5 Unit Price P1 6 7 PLU 6 Cook By Date P1 7 14 PLU 7 Shelf Life P1 9 ...

Страница 16: ...PLU number which will be assigned Press SAVE key to store repeat steps to enter other speed keys or press ESC key to exit next mode 3 1 Edit Store Name Press Enter key P2 Press Speed Key P3 1 1 Edit Store name P2 1 1 Speed Key No 1 Assigns PLU No 123456 P2 Press Speed Key P3 3 Edit Master Files 2 2 E ED DI IT T S SP PE EE ED D K KE EY Y 3 3 E ED DI IT T M MA AS ST TE ER R F FI IL LE ES S ...

Страница 17: ... Non PLU Name Non PLU Name is used to store commodity name not recorded in PLU Press Enter key Enter commodity name USE In sales mode enter unit price and put a weight on the platter Press Enter key 3 3 Non PLU Group Code Non PLU Group Code is used to store Group Code not recorded in PLU Press Enter key P3 1 Edit Store Name 1 The World Shopping Center P3 1 Edit Store Name 2 P3 2 2 Non PLU Name P3 ...

Страница 18: ...ded in PLU Press Enter key Enter Item Code USE In sales mode enter unit price and put a weight on the platter Press Enter key 3 5 Edit Group Group is used to managing PLUs by categories of commodities for examples meet fruit and vegetable Press Enter key Enter group code and press Enter key P3 5 0 5 Edit Group P3 5 1 2 Edit Group P3 3 20 3 Non PLU Group Code P3 4 4 Non PLU Item Code P3 4 12345 4 N...

Страница 19: ...perator Registration Press Enter key Enter operator code and press Enter key Enter name of operator and press Enter key Max 10 characters x 32 operators Repeat steps to enter another operator or press ESC key twice to the next P3 6 6 Edit Operator P3 6 1 6 Edit Operator P3 6 1 5 Edit Operator Susie P3 6 2 6 Edit operator Linda P3 5 1 2 Edit Group Vegetable ...

Страница 20: ...Enter key Enter sale message code and press Enter key Enter sale message and press Enter key Repeat steps to enter another sale message or press ESC key twice to the next mode Pressing SET key enables to return to the normal mode at here P3 7 7 Edit Sale Message P3 7 1 7 Edit Sale Message P3 7 2 7 Edit Sale Message P3 7 1 7 Edit Sale Message Have a Nice Day ...

Страница 21: ...vailable in normal operation mode Press ESC key twice to the next 5 1 Minimum Weight of Auto Printing Press Enter key P5 1 0 100 1 Minimum Weight of Auto Printing P4 4 Edit Date Time P4 1 123456 xxxxxx Edit Date Time Time HH MM SS P4 2 120910 120910 Edit Date Time Date MM DD YY P4 1 123456 xxxxxx Edit Date Time Time HH MM SS 4 4 E ED DI IT T D DA AT TE E T TI IM ME E 5 5 S SE EL LE EC CT T F FU UN...

Страница 22: ...ss Enter key Select group code and press Enter key codes 0 99 are available 5 3 Select Operator Press Enter key Select operator code and press Enter Key codes 0 99 are available P5 2 1 2 Select Group P5 3 1 3 Select Operator P5 1 0 200 1 Minimum Weight of Auto Printing P5 2 00 2 Select Group P5 3 3 Select Operator ...

Страница 23: ... press Enter key codes 0 99 are available 5 5 Select Date Format Press Enter key Select date format and press Enter key 5 6 Select Sale Message Press Enter key P5 4 1 4 Select Scale P5 5 2 1 YY MM DD 2 MM DD YY 3 DD MM YY P5 4 4 Select Scale P5 5 5 Select Date Format P5 6 6 Select Sale Message ...

Страница 24: ...On And Off Press Enter key Select 1 or 2 default setting is 2 and press Enter key 5 8 Select Add Printing Press Enter key Select 1 or 2 default setting is 2 and press Enter key P5 6 1 6 Select Sale Message P5 7 2 1 Always On 2 PLU Call On P5 7 7 EL On And Off P5 8 2 1 Disable Print 2 Enable Print P5 8 8 Select Add Printing ...

Страница 25: ...rrent time must be set Y Press Enter key Select scale time and press Enter key codes 0 24 are available 5 10 Use Speed Key 120Ea Press Enter key Select 1 or 2 default setting is 1 and press Enter key 5 8 Select Bar Code Press Enter key P5 11 11 Select BarCode P5 9 2 Scale Time P5 9 9 Scale Time P5 10 1 1 Use 60 Ea 2 Use 120 Ea P5 10 10 Use Speed Key 120Ea ...

Страница 26: ...Ex 1 7 digit price DD III PPPPPPP or D IIII PPPPPPP or IIIII PPPPPPP Ex 2 6 digit price DD IIII PPPPPP or D IIIII PPPPPP or IIIIII PPPPPP Ex 3 Printing weight instead of price on the bar code DD IIIII WWWWW Enter barcode format and press Enter key Press ESC key to exit 6 1 Account Group Press Enter key Enter group number and press Enter key group total is printed P5 11 4 1 UPC A 2 UPC B 3 EAN 8 4 ...

Страница 27: ...Enter PLU number and press Enter key PLU total is printed Repeat steps to print another PLU or press ESC key to exit 6 3 Account Daily Press Enter key P6 2 1 Printing PLU Total Accept PLU Number P6 2 2 Account PLU P6 3 3 Account Daily P6 1 1 Printing Group Total Accept Group Number P6 2 1 Printing PLU Total Accept PLU Number P6 2 1 ...

Страница 28: ... number 1 for label printing or 2 for ticket printing and press Enter key For the ticket printing remove the label bobbin on the cartridge and fit the ticket paper roll 7 2 Setting Label Length Press Enter key P6 3 1 Printing Daily Total Accept Date P7 1 1 Select Label or Ticket P7 2 2 Set Label Length P6 3 Printing Daily Total Accept Date 7 7 M MO OD DI IF FY Y L LA AB BE EL L P7 1 1 1 Label 2 Ti...

Страница 29: ... label gap 2 mm Enter gap value of labels and press r key values 0 99 are available 7 4 Select Peel Off Sensor Peel off sensor detects a label peeled or remained on the peel off bar after enabling scale dose not print label to prevent labels jammed Press Enter key Select disable or enable and press Enter key P7 2 40 2 Set Label Length P7 3 20 3 Set Label Gap P7 4 2 1 Disable 2 Enable P7 3 3 Set La...

Страница 30: ...nter adjusting value and press Enter key values 0 99 are available 7 6 Gap Sensor Threshold Level Manual Setting Sensor calibration written in 8 7 Utility Sensor calibration calibrates gap sensor and peel off sensor automatically but this setting gives a manual calibration by entering threshold level Prior to setting the min max levels must be read in 2 6 Self Test Sensor Test Press Enter key Ente...

Страница 31: ...level and press Enter key levels 0 255 are available 7 8 Select Label Format Press Enter key Select label format and press Enter key refer to the APPENDIX 7 9 Select Printing Item Press Enter key P7 7 83 7 Peel Off Threshold P7 8 40 8 Select Label Format P7 8 8 Select Label Format P7 7 7 Peel Off Threshold P7 9 9 Select Printing Item ...

Страница 32: ... set to Y each group code of PLU is printed individually group code is set to N a common group code is printed which has been set in 5 2 Select Function Select group code Enter yes Y or no N Enter yes Y or no N P7 9 1 1 Pack On Date Y P7 9 2 2 Shelf Life Y P7 9 3 3 Plu Number Y P7 9 4 4 Group Code N P7 9 5 5 Barcode Y ...

Страница 33: ... yes Y or no N Enter yes Y or no N Enter yes Y or no N Enter number 1 or 2 1 Printing 1 line of store name 2 Printing 2 lines of store name 0 No store name P7 9 6 6 Weight Y P7 9 10 10 Store Name 2 P7 9 7 7 Unit Price Y P7 9 8 8 Total Price Y P7 9 9 9 4 Digit Year Y ...

Страница 34: ...2 2 lines of commodity name Enter yes Y or no N Ingredients Enter yes Y or no N Enter yes Y or no N and press Enter key Enter yes Y or no N and press Enter key P7 9 11 9 Commodity Name 1 P7 9 12 12 Ingredient N P7 9 13 13 Tare N P7 9 14 14 Sales Message N P7 9 15 14 Current Time N ...

Страница 35: ... press Enter key 7 11 Set Printing Contrast Enter value between 0 400 and press Enter key bigger value has a higher contrast a value 45 is fixed at high speed Press ESC key to exit 7 12 Set Number of Label Press Enter key P7 10 10 Select Print Speed P7 10 3 1 1 Low 2 Medium 3 High P7 11 200 11 Set Print Brightness P7 12 12 Set Number of Label ...

Страница 36: ...y Press Enter key Select 1 Low 2 Medium 3 High and press Enter key 7 14 Select Subtotal Label Press Enter key Select Subtotal Label Press ESC key to exit P7 12 1 12 Set Number of Label P7 13 13 Gab Sensor Sensitivity P7 13 2 1 Low 2 Medium 3 High P7 14 14 Select Subtotal Label P7 14 2 14 Select Subtotal Label ...

Страница 37: ...mmend 7 000 20 000 counts higher or lower counts is a mainly load cell defective but rarely Analog board on the main board may be affected when zero count is an out of range of 7 000 20 000 firstly replace the load cell and then Analog board may be replaced And a stable A D count is recommended 2 count at an indicated value as a stable A D reading if count is unstable or fluctuated replace the Ana...

Страница 38: ... 7 31 3 27 8 27 9 28 0 28 1 28 2 28 3 28 4 28 5 28 6 28 7 28 8 31 4 28 9 29 0 29 1 29 2 29 3 29 4 29 5 29 6 29 7 29 8 29 9 31 5 30 0 30 1 30 2 30 3 30 4 30 5 30 6 30 7 30 8 30 9 31 0 NUMERIC KEY CODE 12 13 14 19 23 7 8 9 18 22 4 5 6 17 21 1 2 3 16 20 0 10 11 15 Press ESC key to exit 8 1 3 Display All numeric displays are checked by counting 00000 99999 continuously Press ZERO key to exit 0 0 13510...

Страница 39: ...y to exit 8 1 6 Sensor Test The outputs of the sensors are indicated peel off sensor indicates a high value when a label blocks the sensor a low value when no label at the front of the peel off sensor Gap sensor indicates a high value when a label with backing paper stand in the gap sensor a low value is indicated at gap of a labels between label and label Recommended sensor indications Peel off s...

Страница 40: ... 3 key scale feeds labels and displays medium values Press ESC key to exit 8 2 Print PLU PLUs which assigned in starting No to End No are printed Enter starting PLU No and press Enter key Enter end PLU No and press Enter key P8 7 7 Gap Sensor xxx Peel Off Sensor xxx P8 8 1 Analog 2 Key Board 3 Display 4 RS 232C P8 2 1 Start PLU No P8 2 1 5 End PLU No ...

Страница 41: ...o the other scale Scale to Scale Connect RS 232C cable between two scales and press Enter key to transfer Press ESC key to exit 8 4 Del Account Press Enter key account data is deleted display Press ESC key to exit P8 3 3 Transmit Data P8 9 1 Self Test 2 Print PLU 3 Trans Data 4 Del Account ...

Страница 42: ...42 P a g e Adam Equipment Company 2010 1 CHANGING LABEL ROLL 1 10 0 T TH HE E O OT TH HE ER RS S ...

Страница 43: ...43 P a g e Adam Equipment Company 2010 2 CLEANING THERMAL PRINT HEAD ...

Страница 44: ...44 P a g e Adam Equipment Company 2010 1 11 1 S SA AM MP PL LE E L LA AB BE EL L F FO OR RM MA AT T ...

Страница 45: ...nal packaging and with correct documentation for a claim to be processed All claims are at the sole discret ion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installat ion unauthorised modifications or attempted repair or failure to observe the requiremen...

Страница 46: ...46 P a g e Adam Equipment Company 2010 ...

Страница 47: ...l area is likely to cau se harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance wit h the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equi...

Страница 48: ... Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specificatio...

Отзывы: