Adam Equipment 

 
 
 
 

 
 
 

MDW – 300L 

HEALTH AND FITNESS SCALE with BMI 

 
 
 

 

 

 

 
 

ADAM EQUIPMENT CO. LTD.   

p.n. 700660159 Rev. A2, Apr 2014 

 

 

Содержание MDW - 300L

Страница 1: ...Page 1 Adam Equipment MDW 300L HEALTH AND FITNESS SCALE with BMI ADAM EQUIPMENT CO LTD p n 700660159 Rev A2 Apr 2014 ...

Страница 2: ...PLAY AND KEY DESCRIPTIONS 4 4 0 SETTING UP THE SCALE 5 5 0 FUNCTION 7 5 1 WEIGHING 7 5 2 MEASURING HEIGHT 8 5 3 MEASURING BODY MASS INDEX BMI 8 6 0 CALIBRATION 9 7 0 USER PARAMETERS 10 8 0 RS232 COMMUNICATIONS 11 9 0 ERROR MESSAGES 15 10 0 WARNING 15 WARRANTY INFORMATION 17 ...

Страница 3: ...ty 2 kg 4lb Scale division 0 05kg 0 1lb Height range 60 cm 212 cm 24 83 Division of measurement height used in BMI calculation entry via keypad 1cm 0 5 Division of measurement height measurement 0 1cm Display LED display Size of platform 375 X 275 mm 14 75 X 10 8 Overall dimension height pillar in lowest position 570 X 275 X 1310 mm 22 4 X 10 8 X 51 5 Net weight 13 kg 29 lb Environment for Use Tem...

Страница 4: ...s when required DISPLAY DESCRIPTIONS Kg Indicates when the scale is weighing in Kilograms Lb Indicates when the scale is weighing in Pounds Hold Indicates when the scale has held the weight reading shown on the display It will flash until it locks into the stable reading when it will then remain on for a preset time when it has held the displayed reading BMI Indicates when the scale is displaying ...

Страница 5: ...acket and secure the bracket to the indicator 1 4 Make sure the screws are securely tightened 5 Place the cable 4 into the tube support 6 on the scale base 6 Insert the pillar 3 into the tube support 6 7 Rotate the pillar to position the indicator 1 in the direction desired and then secure using the 2 screws 5 into the fixing tube 6 8 Locate the load cell cable 13 ready for connection ...

Страница 6: ...nside the base 16 12 The cables should be fixed to the base using the clip provided 14 13 Locate the fixing bolt and washer 10 used to secure the height rod to the scale base 11 14 Locate the height rod 7 onto the fixing points 9 of the upper and lower brackets 8 12 15 Secure the bolt and washer to the bracket on the base 10 16 Tighten the bolt on the upper bracket 9 ...

Страница 7: ...D will indicate the chosen weighing unit Overload display When FULL appears on the display it shows that the load on the platform is over the maximum capacity Under these circumstances it is necessary to reduce the load otherwise the sensor or the platform will be damaged Hold Function To lock the weighing result press the Print Hold key The LED will flash until a stable reading has been obtained ...

Страница 8: ...mpute the BMI Press and hold the Unit BMI key to enter the BMI mode The display will show the last height value used Cm123 or In123 depending on which weighing unit you are currently using The height entry unit Cm or In will be flashing to show you which unit you are currently in use the Up arrow key to change the height entry unit between Cm to In as required Enter your height using the arrow key...

Страница 9: ...00 0 and the lb LED depending on which unit you chosen this is the default calibration weight from the factory Press the UNIT key to select the calibration weight unit that you want to calibrate in Press the ON OFF key to exit the calibration mode at this point or press the Print Hold key to choose a different calibration weight value 50kg 100kg 150kg 200kg 250kg 300kg or 100lb 200lb 300lb 400lb 5...

Страница 10: ...et up mode 3 Parameters setting summary Parameter x xy Factory Set Setting A o t 00 15 05 Auto off time No auto off 00 01 15 minutes auto off time P H 0 1 2 1 0 Only Print Function 1 Only Hold Function 2 both HOLD and PRINT function pressed down less 3s this key works as Print function pressed down more than 3s this key works as HOLD function H t 0 4 0 Hold time 0 no time limit 1 10 seconds 2 30 s...

Страница 11: ... if PH has been set to 0 or 2 8 2 When Parameter S F in section 7 is set to 0 No RS232 function The scale will not transmit or receive any data although the scale is equipped with RS232 The RS232 function can be only activated when the scale is in normal weighing mode RS 232 output of weighing data ASCII code 9600 Baud rate fixed 1 start bit 8 data bits 1 stop bit No Parity Connector 9 pin d submi...

Страница 12: ... will be a 7 digit weight data one for minus sign one for decimal point two for measuring unit e g lb kg Units of measure abbreviations are always lower case If the weight is overcapacity the scale will return nine characters the field of minus sign decimal point weight data is filled by If the weight is under capacity it will return nine characters the field of minus sign decimal point and weight...

Страница 13: ...ent scale status the same as pressing the ZERO ON OFF button LF H1H2H3 CR ETX If ZERO function cannot be activated it will return to current scale status 4 Command T CR 54h 0dh Response TARE function is activated and then returns scale status the same as pressing the TARE button LF H1H2H3 CR ETX If TARE function cannot be activated it will return to current scale status 5 Command U CR 55h 0dh Resp...

Страница 14: ... mode 00 not define 11 not define 1 not stable 1 under capacity 1 0 not at zero point 0 not over capacity 1 at zero point 1 over capacity 2 always 0 always 0 0 gross weight 1 net weight 3 0 eeprom OK always 0 always 0 1 eeprom error 4 always 1 always 1 always 1 5 always 1 always 1 always 1 6 always 0 always 1 always 0 7 parity Parity parity ...

Страница 15: ...tions Do not jump while standing on the platform This may damage the sensor inside Do not move the weighing machine violently and abruptly Always move and put down the weighing machine gently Wipe any stains with a soft damp cloth using a detergent then wipe clean with a dry soft cloth Do not use organic solutions or boiling water to clean stains Do not use a water spray for cleaning Keep the weig...

Страница 16: ...Page 16 ...

Страница 17: ...ng and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recomm...

Страница 18: ... Adam Equipment Company 2014 Page 1 ...

Страница 19: ...rence when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct...

Страница 20: ...Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technol...

Отзывы: