Страница 1: ...1 P a g e Adam Equipment Company 2009 Adam Equipment CCSA Coin Count Scale P N 6949 Revision C1 October 2009 ...

Страница 2: ... e Adam Equipment Company 2009 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place ...

Страница 3: ...ARAMETERS 21 5 1 SETTING COIN WEIGHT 21 5 1 1 Procedure 22 5 2 DETERMINING NEW COIN OR TOKEN WEIGHTS 24 5 2 1 Procedure 24 5 3 SECURED FEATURES 25 5 4 1 F1 F1 F1 F1 Baud Rate Setting 26 5 4 2 F2 F2 F2 F2 PARITY 28 5 4 3 F3 F3 F3 F3 SLEEP 29 5 4 4 F4 F4 F4 F4 Weight Calibration 30 5 4 5 F5 Access Code Number 31 6 0 SECURE PARAMETERS 33 6 1 SETTING UP SECURED PARAMETERS 33 6 1 1 F6 SETTING ASCII VAL...

Страница 4: ...4 P a g e Adam Equipment Company 2009 ...

Страница 5: ... FEATURES CCSA 20 Weighing Automatic tare Coin token Counting Memory Accumulation Stainless steel weighing platform Level indicator with adjustable leveling feet Colour coded sealed keypad Large liquid crystal displays LCD Displays for Denomination Quantity and TOTAL value Battery operated for portability 50 hours battery life when fully charged The scales can be upgraded when new coins are releas...

Страница 6: ...he balance battery go flat if you are not using it for a long time you should charge the battery up periodically to make sure the battery dose not lose its charge Keep free from vibration Do not place near heavy or vibrating machinery Avoid high humidity that might cause condensation and keep away from direct contact with water Do not place near open windows air conditioning vents or fans that may...

Страница 7: ...been tared Net and is displaying a net weight The Quantity window displays the number of coins counted An arrow will show whether the weight of new style coins NEW or old style coins OLD was used to count them The TOTAL window shows the value of the coins counted An arrow will also indicate when a value has been stored in memory MEMORY 2 3 KEY DESCRIPTIONS The keypad has 20 keys Other keypads may ...

Страница 8: ... special applications CE Esc Used to clear a coin denomination New Old Toggles between using new and old coin weights when determining the quantity and value of coins on the scale Used when older styles of coins have been replaced by new styles with a different weight An arrow in the Quantity window indicates the selection M Enters a new entry into memory The memory will accumulate up to 99 entrie...

Страница 9: ...final total is displayed Print Prints a complete record of all data stored in memory Displays the total count and value from memory CE Esc Resumes normal operation Zero When the weight on the scale is within 2 of the zero at power on pressing Zero will set the scale to zero If it is outside this range then the Tare function is used Tare Tare function allows the scale to display zero weight when an...

Страница 10: ...rned off to protect the battery from getting damaged 2 5 BACKLIGHT OPERATION The LCD display has a backlight that operates automatically To maximise the battery life it may be necessary to turn the backlight off Hold the Print key for 4 seconds to enter the backlight control mode Use the MC key to change the setting for the backlight to OFF ON set to on for full time or AUTO set to on only when th...

Страница 11: ... to change the date and time The display will show the current time format H m S Enter the time using the numeric keys using a 24 hour clock format 3 41PM is 154100 Press the Total key to accept the time The display will show the current date format Press the MC key to change the date format Available formats are Y m d year month day m d Y month day year d m Y day month year Press the Total key to...

Страница 12: ... at the zero condition The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to press Zero to re zero the scale whenever a small amount of weight is shown even though the platform is empty 3 2 TARING Taring is used to eliminate the weight of a container so that only the net weight is displayed Zero the scale by...

Страница 13: ...ation window the number of coins in the Quantity window and the value of the coins in the TOTAL window To change to Old or New types of coin press the New Old key Note an arrow in the Quantity window shows the selection The Scale determines the weight of the coins and divided the weight by the average weight for the denomination selected This determines the Quantity of coins The total value is the...

Страница 14: ...y 1 and the total quantity of coins counted in memory Quantity display and the total value of coins that have been stored into memory TOTAL display For Example 0 20 285 57 00 Press M 1 285 57 00 After 2 seconds the scale will return to normal operation Put next batch of coins on the scale select denomination R1 1 00 108 108 00 Press M 2 393 165 00 After 2 seconds the scale will return to normal op...

Страница 15: ...ght on the scale must return to zero before another value is allowed to be stored into memory NOTE Tokens cannot be added to memory as they do not have a value associated with them If tokens are to be added to memory with coins an error message will be displayed ErrOr TYPE After that the scale will return to normal operation ...

Страница 16: ...the quantity and value for this first item 1 for 1 second and then 0 20 285 57 00 Pressing MR again will show the second set of data 2 for 1 second and then 1 00 108 108 00 Continue to press MR until the total values from the memory are shown 3 TotAL 175 50 After 2 seconds the scale will return to normal operation If MC is pressed when the total is shown 3 498 175 50 as in the above example all da...

Страница 17: ...weights denominations and symbols used The parameters for the RS 232 interface are The scale does not require RTS CTS signals to be used 4 2 PRINTING The scale will output data when the following keys are pressed M outputs the current record at the same time as the results are stored in the memory See Section 3 4 Baud Rate 300 600 1200 2400 4800 or 9600 baud Parity None Odd or Even Data bits 8 or ...

Страница 18: ...ted record shows as follows Any time the Total key is pressed the current totals held in memory are printed After the 2nd weighing in the previous sample the printed record shows as follows Date 2009 01 05 Time 12 23 15 Record 1 Denomination 0 20 Quantity 285 Amount R 57 00 Date 2009 01 05 Time 12 23 15 Total Quantity 498 Total Amount R 175 50 ...

Страница 19: ...l operation The Print key will record a list of all sets of data stored in the memory and the total amounts For the sample above the printed record is Date 2009 01 05 Time 12 23 15 Record 1 Denomination 0 20 Quantity 285 Amount R 57 00 Record 2 Denomination 1 00 Quantity 108 Amount R 108 00 Record 3 Denomination 0 10 Quantity 105 Amount R 10 50 Total Quantity 498 Total Amount R 175 50 ...

Страница 20: ...es K01 1 00 3 995 11 971 cr lf 1R key assume key 01 With denomination 1 00 weight of new coin 3 995g weight of old coin 11 971g K07 0 20 4 489 2 505 cr lf 5c key assume key7 With denomination 0 20 weight of new coin 4 489g and weight of old coin 2 505 K10 T3 1 234 2 456 cr lf Token 3 key assume key10 With of a token number 3 weight of new token 1 234g and weight of old token 2 456g Key numbers are...

Страница 21: ... Secured Parameters Section 6 0 for details on how this can be changed In addition each coin has a weight associated with the old style or a new style For South Africa the initial values set for the coins are Coin Denomination New Wt1 Old Wt2 Token1 T0 0 000 0 000 Token2 T1 0 000 0 000 1c 1 489 2 996 2c 2 995 3 974 5c 4 489 2 505 10c 1 987 3 960 20c 3 488 5 934 50c 4 910 9 488 R1 3 995 11 971 R2 5...

Страница 22: ...ays will show Pin Enter the access code 4 numbers using the numeric keypad An will be displayed for each number Pin Press the Total key If the access code number was correct it will advance to the unit weight setting program otherwise it will return the scale to counting The first value displayed is the first token value The displays show denomination unit weight t1 0 00 0 00 To select another den...

Страница 23: ...meric keys to enter a new unit weight For example press 1 9 8 and 5 to set the numeric keys are shown with small numbers in the corner of the keys 0 10 1 985 0 00 Press Total to store the new value SAVE will be displayed briefly Repeat the procedure for any other changes necessary If a printer is connected press the Print key to list of all the denominations and their values At any time press the ...

Страница 24: ...eight will be displayed until CE Esc or any other key except Tare is pressed to return to normal operation The Tare key will continue to function as normal to zero the display Verify the scale calibration by placing a known weight on the platform If the scale is not accurate 2g it must be re calibrated before proceeding See Section 5 4 3 for calibration details Place the tokens or coins to be chec...

Страница 25: ... a number of functions that can only be accessed by a qualified user Two levels of security are available For the first level of security a user password is required to allow the access to change the piece weight for the different denominations of coins See Section 5 1 The second level of security will allow more functions to be set See section 6 0 The first level of functions includes F1 Baud Rat...

Страница 26: ... then release the key Pin Enter the default access code 0000 Pin Press the Total key The first function is F1 Baud Rate Setting F1 bAud SEt Press the MC key to advance to each of the other functions or CE Esc to return to normal operation after running a self test 5 4 1 F1 F1 F1 F1 Baud Rate Setting To change the baud rate used with the RS 232 interface follow this procedure When the display is sh...

Страница 27: ...cycle through the options which are 600 1200 2400 4800 and 9600 F1 bAud 4800 New baud rate Press CE Esc to escape without changes before it is stored or press the Total key to confirm and store the new value F1 bAud SEt To move to the next function press MC F2 ParitY SEt Or press CE Esc to return to normal operation ...

Страница 28: ...tY n 8 1 Current parity None 8 data bits 1 stop bit For a new parity setting use the MC key to cycle through the following options n81 Parity None 8 data bits and 1 stop bit E71 Parity Even 7 data bits and 1 stop bit o81 Parity Odd 7 data bits and 1 stop bit F2 ParitY E 7 1 Press CE Esc to escape without changes before it is stored or press the Total key to confirm and store the new value F2 Parit...

Страница 29: ...he time can be from 1 to 10 minutes or disabled To change the time follow this procedure When the display is showing F3 SLEEP SEt Press the Total key F3 SLEEP 1 Current setting 1 minute For a new value use the MC key to cycle through the options 1 5 or 10 minutes 0 will disable the automatic turn off function Press CE Esc to escape without changes before it is stored or press the Total key to conf...

Страница 30: ...fy the calibration is within 10 of this calibration This prevents calibration with no weight on the scale or with grossly wrong weights When the display is showing F4 CAL SEt Press the Total key The display will show the following CAL 0 000 12345 The number in the TOTAL window is the number of internal counts representing the zero weight from the analog to digital converter within the scale Make s...

Страница 31: ...tion F5 ACCES CAL Remove the weight from the scale If CE ESp is pressed during calibration return to normal operation without doing the calibration 5 4 5 F5 Access Code Number To change the user access code number used to enter the section of the program for changing coin weights see Section 5 2 follow this procedure This parameter can only be accessed by skipping the F3 Calibration function by us...

Страница 32: ...nfirm and store the value The scale will ask you to repeat the number again for security Pin 2 Enter the new access code Pin 2 Press CE Esc to escape without changes before it is stored or press the Total key to confirm and store the value F5 ACCES Set To return to normal operation press the CE Esc key ...

Страница 33: ...ion 5 1 1 The first function shown is F1 the Baud Rate Setting F1 bAud SEt This procedure gives access to the following parameters F1 Baud Rate Setting F2 Parity setting F3 Sleep F4 Weight Calibration F5 Access Code Number Setting F6 Symbol for Denomination Setting F7 Denomination Setting F8 Linearity Calibration F9 Factory Calibration Values See Section 5 4 for details of Functions F1 to F5 These...

Страница 34: ... to represent the value of the money used follow this procedure When the display is showing F6 SIGN SEt Press the Total key and the display will show F6 52H SEt Current symbol used in hex 52H R To enter the new ASCII value for the symbol use the key to select the digit to change flashing and then use MC to increment the digit 0 9 A B C D E F 0 F6 24H SEt New symbol used 24H ...

Страница 35: ... Esc to escape without changes before it is stored or press the Total key to confirm and store the value Currenc Symbo Value Rand R 52 Dollar 24 Other values for a particular symbol can be found in a table of ASCII values A sample table is attached ...

Страница 36: ...nomination values associated with each key It may be necessary to change keypad designs for other denominations When the display is showing F7 dEM SEt Press the Total key The display will show the decimal point position Point AddES 0 00 Decimal point current position Press the MC key To select either 0 00 0 0 or 0 Press Total to set the decimal point The displays will show F7 dEM kEy Press the den...

Страница 37: ...ew value for this key position simple use the numeric keys and press Total to save the new value To set a key position for a token press the MC to set T1 T2 etc up to T8 The display will show SAVE and then display F7 dEM kEy You can select another key if necessary When all changes have been made press the CE Esc key to return to the parameters Press MC to advance to the next parameter 6 1 3 F8 Lin...

Страница 38: ... number of internal counts representing the zero weight from the analog to digital converter within the scale Make sure no other weights are on the scale Press the Total key to set the zero point The display will show LoAd 1 10 23456 Place 10kg mass on the scale and then press the Total key The display will then show LoAd 20 23456 Place 20kg mass on the scale and then press the Total key The displ...

Страница 39: ... within 10 of the previous factory calibrations This value will also overwrite the user calibration value as set in F3 When the user calibration is performed the results must agree within 10 of the factory calibration This prevents calibration with no weight on the scale or with grossly wrong weights When the display is showing F9 FACt Set Press the Total key The display will show 0 000 xxxxxx Mak...

Страница 40: ...09 Place the weight on the scale When the scale is stable Press the Total key The display will then show SPAN PASS The scale will return to the Function menu Press CE Esc to return to normal operation or MC to select a different function ...

Страница 41: ...e Factory Calibration will be restored to the balance 6 2 2 Shortcut to Calibration without using Functions To calibrate the scale without entering the function menu press and hold the MC key while power is turned on The scale will immediately go to the calibration function The display will show the following CAL 0 000 12345 Proceed with calibration as normal See section 5 4 4 When completed the s...

Страница 42: ... CAUSES Err 1 Error setting a date Trying to set a date that is not realistic Err 2 Error setting time Trying to set a time that is not realistic Err 4 Initial Zero is greater than allowed typically 4 of the maximum capacity when power is turned on or when the Zero key is pressed Weight is on the pan when turning the scale on Excessive weight on the pan when zeroing the scale Improper calibration ...

Страница 43: ...TE Weight is not displayed except in special test program Tare Range 20 kg Working Temperature 0ºC to 40ºC Platform 225 x 275mm Overall 315 x 355 x 110mm Battery Life 50 hours typical Power 230 VAC 50 60 Hz 10 watts Net Weight 4 1 kg Battery Life is less when the optional backlight is used ...

Страница 44: ...44 P a g e Adam Equipment Company 2009 ...

Страница 45: ...inal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirement...

Страница 46: ...ment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority t...

Страница 47: ...47 P a g e Adam Equipment Company 2009 ...

Страница 48: ... Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of...