![ACV BNE 2 Condens Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/acv/bne-2-condens/bne-2-condens_installation-operation-and-maintenance-instructions_2845459005.webp)
en
5
EN
664Y5900 • A
USER'S GUIDE
Description
1. ON/OFF master switch of the boiler -
To turn the boiler on and off.
2. Summer-winter switch -
To activate or deactivate the heating pump.
3. Energy source selector switch -
To activate or deactivate the heating pump and the burner, and
turn on or off a 2.4 kW heating element to meet the need in domestic hot water
4.
Heating element indicator -
The built-in indicator lights when the heating element is activated.
5. Safety cutout warning indicator -
The built-in indicator lights when the flue gas or primary circuit
water temperature is too high.
6. DHW Thermometer -
Shows the temperature of the domestic hot water.
7. Domestic hot water temperature adjustment thermostat -
In DHW mode, the domestic hot
water temperature can be set from 60 to 80°C.
8. Temperature and pressure gauge -
Indicates the boiler temperature and the primary circuit
pressure.
9. Heating temperature adjustment thermostat -
Allows to set the boiler between 60 and 90°C.
It is recommended to set the thermostat 10°C above the set point of the domestic hot water
adjustment
thermostat
.
instrUctions for the end-User
Essential recommendations for safety
•
Do not store any flammable or corrosive products, paint, solvents, salts, chloride products
and other detergent products near the appliance.
•
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless supervised or
unless they have been given instruction concerning the use of the appliance by a person
responsible for their safety.
periodic checks
Essential recommendations for the correct operation of the appliance
•
Check regularly that the system water pressure is at least 1 bar when cold.
•
If it is required to top up the system to maintain the minimum recommended water
pressure, only add small amounts of water at a time. If a large amount of cold water is
added in a hot boiler, the boiler can be damaged definitively.
•
If the boiler safety cutout system is frequently activated, contact your installer.
•
If the system needs to be refilled repeatedly with water, please contact your installer.
•
Regularly check that there is no water on the floor in front of the boiler. If there is, please
call your installer.
1
2
3
4
5
7
6
8
9
Содержание BNE 2 Condens
Страница 1: ...EN 21 8 kW BNE 2 Condens 664Y5900 A Installation operation and maintenance instructions ...
Страница 22: ...EN en 22 Installation 664Y5900 A Boiler Preparation 5 3 4 1 2 6 ...
Страница 23: ...en 23 EN Installation 664Y5900 A 9 8 10 11 7 1 2 ...
Страница 24: ...EN en 24 Installation 664Y5900 A Burner installation 2 6 3 4 90 mm 5 1 1 2 ...
Страница 25: ...en 25 EN Installation 664Y5900 A 8 2 1 7 9 ...
Страница 40: ...EN en 40 664Y5900 A Declaration of conformity EC ...
Страница 41: ...en 41 EN 664Y5900 A Declaration of conformity RD 17 7 2009 ...
Страница 42: ...EN en 42 664Y5900 A Markings Labels Pending approval ...