Acuva Eco Скачать руководство пользователя страница 3

 

 

  

 

 

Acuva Technologies Inc. #162-2366 Main Mall, Vancouver BC V6T 1Z4 Canada     www.acuvatech.com 

 

1.1

 

: Installation instructions for the Acuva Water Purification Systems:

 

 

1.

 

Find an under-counter position for the UV device and the pre-filter to be mounted that 
will allow space for the PEX tubing to be connected without needing to bend the tube to 
the point where they risk pinching or folding. 

2.

 

Mount the Din-Rail (Item not shown in Fig.4) that will hold the UV device with two #10 
wood screws and the mounting clips (Item no.3) for the pre-filter into position. 

3.

 

To install the ½

” PEX

-

3/8” OD Tee & 

shutoff valve (Item no.1) to the cold-water line, assure 

that the cold-water line is not under pressure, that the water pump is not powered or 
that water flow is cut off by an upstream shutoff valve, expect some water to drain from 
the cold-water line when cut, and cut the cold-water line with PEX tube cutters to insert 

the ½” 

cold-water line to the 

½” female 

ends of the Tee, push the tubes into the Tee as 

far as possible and pull slightly to assure that the seal is secure. 

4.

 

Attach a length of the provided 3/8” PEX tubing 

(Item no.2) that will connect the Tee to 

the Pre-Filter (Item no.4)

, and insert the tube into the 3/8” OD female end of the Tee

push the tube into the Tee as far as possible and pull slightly to assure that the seal is 
secure. 

5.

 

To install the Pre-Filter, wrap the threa

ds of the 3/8” OD –

 

¼” MNPT Adapters

 (Item no.5) 

with  Teflon  Tape  and  screw  these  adapters  into  the  2  female  ends  of  the  pre-filter, 

connect the 3/8” PEX tube from the Tee into the inlet side of the pre

-filter while making 

sure that water will flow in the proper direction as indicated on the filter, push the tube 
into the adapter as far as possible and pull slightly to assure that the adapter is properly 
sealed. 

6.

 

To install the UV device (Item no.7), wrap Teflon Tape onto the threads of the 3/

8”

OD-

3/8”

MNPT Adapters (Item no.6) and fasten these adapters into the inlet and outlet female 

ends of the UV device. 

7.

 

Snap the Pre-Filter to its Clips and mount the UV device to the Din-Rail as seen in Figure 
5. 

8.

 

Cut  a  length  of  3/8”  PEX  tubing  that  will  connect  the  Pre

-Filter  to  the  UV  device  inlet 

female adapter with the tubing by pushing the tube into the adapters as far as possible 
and pulling slightly to ensure that their seals are secure. 

9.

 

Cut a short length of 3/8” tubing and connect to UV 

device female outlet adapter and 

attach the 3/8”

OD-

¼” Union

 (Item no.9) to the end o

f the 3/8” tube.

 

10.

 

Cut a length of ¼” PEX tubing

 (Item no.10) that is long enough 

to connect the 3/8”

OD-

¼” 

Union to the faucet and proceed to the faucet installation. 

11.

 

For the Acuva Eco only, install the provided flow restrictor (Item no.11) inline with the 

¼”

 

PEX tubing. 

 
 

Содержание Eco

Страница 1: ...Acuva Technologies Inc 162 2366 Main Mall Vancouver BC V6T 1Z4 Canada www acuvatech com Installation Instructions Acuva Eco UV LED Water Purifier Acuva Arrow UV LED Water Purifier ...

Страница 2: ... The Acuva Arrow system has a built in flow regulator while only the Acuva Eco requires a flow restrictor Item No 11 in Figure 4 The Acuva Arrow has a built in flow sensor and is activated with the flow of water while the Acuva Eco is manually activated with the Acuva Smart Faucet Item No 12 in Figure 4 Fig 4 Plumbing Diagram Fig 5 Mounting the UV Chamber to the Din Rail Fig 6 UV Indicator Light ...

Страница 3: ...e Tee as far as possible and pull slightly to assure that the seal is secure 5 To install the Pre Filter wrap the threads of the 3 8 OD MNPT Adapters Item no 5 with Teflon Tape and screw these adapters into the 2 female ends of the pre filter connect the 3 8 PEX tube from the Tee into the inlet side of the pre filter while making sure that water will flow in the proper direction as indicated on th...

Страница 4: ...ance is felt then tighten with a wrench while being careful not to over tighten 1 3 Final Installation Steps 1 Once the UV device is connected to the faucet with PEX tubing plug the faucet power cord into its Jack on the UV device 2 Once the faucet power cord is connected to the UV device connect the 12V DC power source to the UV Chamber Unit Power Jack 3 Activate the cold water pressure in the pl...

Страница 5: ...Warning Failure to properly winterize the device before it is exposed to freezing temperatures can lead to damage and water leakage To prevent freezing pump a non toxic antifreeze into the water system Open the point of use faucet connected to the Acuva device and continue to pump non toxic antifreeze until you see the antifreeze coming out of the faucet In the spring remember to flush with fresh ...