5-in-1 Sensor Installation Guidelines

INSTALLATION HEIGHT 

Mount the sensor at a minimum height of 5 feet 

(1.5 meters) off the ground, in an open area. Higher is better for wind 

measurements- the National Weather Service recommends 33 feet  

(10 meters) high! 

MOUNTING OPTIONS 

The included mounting bracket is designed to screw 

directly onto wooden posts or surfaces that are 2”x4” or larger. The sensor 

can also be mounted directly to 3/4” steel pipe (available at hardware stores 

and home centers).

SOLAR CELL INSTALLATION 

Install the 

sensor with the 

solar cell facing SOUTH. 

This ensures the cell receives as much sun 

as possible and orients wind direction.

5-in-1 Sensor Installation

1.  Fasten mounting base (included) to a 

post or pole (not included) using the 4 

longer screws included in the hardware 

bag.

2.  Insert the mounting base into the hole 

on the bottom of the sensor.

3.  Make sure the arrows on the top of 

the sensor are pointed in the proper 

direction and the bubble level is 

centered. The solar cell should be 

facing south to properly orient the 

wind direction.

4.  Fasten the sensor into the mounting 

base using the 2 shorter screws 

included in the hardware bag.

The 5-in-1 sensor is now ready to use.

Clear Data Collected During Installation

When installation is complete, clear erroneous data from the display unit by 

pressing the “CLEAR TODAY” button, on the back of the display inside the 

battery compartment. This button will clear data recorded since 12:00 am.

Basic Setup is Complete

The 5-in-1 sensor will now synchronize with the display unit. It may take a few 

minutes for synchronization to complete. If both or one of the units appear to 

be functioning improperly, please refer to the troubleshooting section.

SOUTH

(1.5 meters)

NO OBSTRUCTIONS

ABOVE OR AROUND

Содержание 01602BPDIA2

Страница 1: ...ts 5 in 1 3 Features Display Unit 4 Back of Display Unit 6 Setup 7 5 in 1 Sensor Setup 7 Display Unit Setup 8 Set the Time Date 9 Measurement Units 10 Placement Guidelines 11 5 in 1 Sensor Installatio...

Страница 2: ...D screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 5 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5 Snap in d...

Страница 3: ...ion heating resulting in more accurate temperature measurement 3 A B C Switch ID code that must match display s A B C switch to ensure units synchronize 4 Battery Compartment 5 Temperature Humidity Se...

Страница 4: ...4 Features Benefits Display Unit 1 31 32 33 34 30 29 28 27 26 25 24 22 20 23 21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 16...

Страница 5: ...ll time low and date recorded for current category selected on display 16 Press twice for all time high and date recorded 20 Record Lows Shown for current category selected on the display 16 21 Clear...

Страница 6: ...asy wall mounting 3 Battery Compartment Cover 4 A B C Switch ID code that must match 5 in 1 sensor s A B C switch to ensure units synchronize 5 Clear Today Clears data recorded since 12 00am 6 Reset F...

Страница 7: ...ne or lithium batteries for the best product performance Heavy duty or rechargeable batteries are not recommended The 5 in 1 sensor requires lithium batteries in low temperature conditions Cold temper...

Страница 8: ...WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an...

Страница 9: ...irm hour selection 5 Press the up or down arrows to adjust minutes 6 Press the button to confirm minute selection The clock is now set Set the Date 1 Press the up or down arrow buttons until SET DATE...

Страница 10: ...Category part of the display unit 2 Press the button to set the unit preference 3 Press the up or down arrows to select STAND for standard or METRIC for metric units 4 Press the button to confirm you...

Страница 11: ...away from large metallic items thick walls metal surfaces or other objects that may limit wireless communication PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet 9 m away from electroni...

Страница 12: ...he hardware bag 2 Insert the mounting base into the hole on the bottom of the sensor 3 Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble level is centere...

Страница 13: ...ther forecaster displays the current pressure and the direction it s trending FALLING STEADY or RISING Rainfall Event The rainfall feature tracks rain accumulation over all time the current month and...

Страница 14: ...lue by pressing the up or down arrow buttons 4 Press the button to confirm a value 5 Next press the button to activate the alarm The alarm ON indicator will highlight on the display Alarm is now progr...

Страница 15: ...tall batteries in display unit 4 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Outdoor temperature is flashing or showing dashes Flashing of the...

Страница 16: ...ou may need to clean inside the sensor Video available at www acurite com 5in1 Inaccurate wind readings What is wind reading being compared to Pro weather stations are typically mounted at 30 ft high...

Страница 17: ...Cup Remove and empty rain collector debris filter The debris filter is located in the rain collector funnel Remove from the top by gently squeezing and pulling out Clean the Wind Vane Anemometer Remo...

Страница 18: ...er should take more than 20 minutes to empty a quicker period will result in inaccurate calibration Try to simulate a normal steady rainfall When cup is empty of water display unit should register 1 0...

Страница 19: ...llowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to whic...

Страница 20: ...es are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liab...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...uRite uses patented technology Visit www AcuRite com patents for details Printed in China 01602BPDIA2 INST 020915 It s More than Accurate it s AcuRite offers an extensive assortment of precision instr...

Отзывы: