AcuRite 00826 Скачать руководство пользователя страница 7

OPERATION 

Placement for Maximum Accuracy 

AcuRite sensors are sensitive to surrounding environmental conditions. Proper 

placement of both the display and outdoor sensor are critical to the accuracy 

and performance of this product. 

Display Placement 

Place the display in a dry area free of dirt and dust. Display 

stands upright for tabletop use or is wall-mountable. 

Outdoor Sensor Placement 

Sensor must be placed outside to observe outdoor conditions. 

Sensor is water resistant and is designed for general outdoor 

use, however, to extend its life place the sensor in an area 

protected from direct weather elements. 
Hang the sensor using the integrated hang holes or hanger, or 

by using string (not included) to hang it from a suitable location, 

like a well covered tree branch. The best location is 4 to 8 feet 

above the ground with permanent shade and plenty of fresh air 

to circulate around the sensor. 

Important Placement Guidelines 

• To ensure accurate temperature measurement, place units out of direct

sunlight and away from any heat sources or vents.

• Display and outdoor sensor must be within 165 ft (50 m) of each other.
• To maximize wireless range, place units away from large metallic items, thick

walls, metal surfaces, or other objects that may limit wireless communication.

• To prevent wireless interference, place both units at least 3 ft (.9 m) away

from electronic devices (TV, computer, microwave, radio, etc.).

(165 feet maximum) 

(50 meters) 

Setup is Complete 

The sensor will now synchronize with the display. It may take a few minutes for 

synchronization to complete. Please refer to the troubleshooting section of this 

manual if anything appears to be functioning improperly. 

Using the Thermometer 
High & Low Records 

The display will automatically cycle through today, 48 hour, and all-time high 

& low temperature records. All-time high & low records reflect the minimum 

and maximum temperature recorded since the unit was powered on, since 

the batteries were changed, or since it was manually reset (whichever was 

most recent). To manually reset the high/low records currently being viewed, 

press and hold the UP or DOWN button on the back of the display for 

3-5 seconds.

Troubleshooting 

Problem 

Possible Solution 

Outdoor 

temperature 

is flashing or

 

showing dashes 

Flashing of the outdoor temperature is generally an 

indication of wireless interference. 

1. Bring both the sensor and display indoors and

remove at least one battery from each.

2. Reinstall the battery in the outdoor sensor.
3. Reinstall the battery in the display.
4. Let the units sit within a couple feet of each other

for a few minutes to gain a strong connection. 

• Relocate the display and/or the outdoor sensor. The

units must be within 165 ft (50 m) of each other.

• Make sure both units are placed at least 3 feet (.9 m)

away from electronics that may interfere with the

wireless communication (such as TVs, microwaves,

computers, etc).

• Use standard alkaline batteries (or lithium batteries

in sensor when temperature is below -4ºF/-20ºC). Do

not use heavy duty or rechargeable batteries. NOTE:

It may take a few minutes for display and sensor to

synchronize after batteries are replaced.

Inaccurate 

temperature 

• Make sure both the display and outdoor sensor are

placed out of direct sunlight and away from any heat

sources or vents.

Display screen 

not working 

• Check that the batteries are installed correctly.

Batteries may need to be replaced.

If your AcuRite product does not operate properly after trying 

the troubleshooting steps, visit www.AcuRite.com or call 

(877) 221-1252 for assistance.

Содержание 00826

Страница 1: ...istration 2 Features Benefits 2 Setup 4 Install or Replace Batteries 4 Set the Time Units 5 Placement Guidelines 6 Using the Thermometer 7 Troubleshooting 7 Care Maintenance 8 Specifications 8 FCC Inf...

Страница 2: ...ng this product Locate the tab and peel off to remove Package Contents 1 Display with Tabletop Stand 2 Outdoor Sensor 3 Instruction Manual PRODUCT MUST BE REGISTERED IMPORTANT TO RECEIVE WARRANTY SERV...

Страница 3: ...recorded for 5 5 Record Timespan Indicates viewing records for today last 48 hours or all time 6 Display Low Battery Indicator 7 Current Indoor Temperature Arrow icon indicates direction temperature...

Страница 4: ...battery compartment as shown Follow the polarity diagram in the battery compartment 3 Replace the battery cover PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCO...

Страница 5: ...cted flashing item press and release the UP or DOWN buttons press and HOLD to fast adjust To save your adjustments press and release the SET button again to adjust the next preference The preference s...

Страница 6: ...ocation like a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To...

Страница 7: ...ry in the display 4 Let the units sit within a couple feet of each other for a few minutes to gain a strong connection Relocate the display and or the outdoor sensor The units must be within 165 ft 50...

Страница 8: ...designed to provide reasonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and use...

Страница 9: ...f ours from date of sale will upon examination by us and at our sole In no case shall our liability for any claim relating to our option be repaired or replaced by us Transportation costs and products...

Страница 10: ...to provide you with information you can depend on to Plan your day with confidence www AcuRite com Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument C...

Отзывы: