Placement for Maximum Accuracy

AcuRite sensors are sensitive to surrounding environmental conditions. Proper 

placement of both the display and outdoor sensor are critical to the accuracy 

and performance of this product.

Display Placement

Place the display in a dry area free of dirt and dust. Display 

stands upright for tabletop use or is wall-mountable.

Outdoor Sensor Placement

Sensor must be placed outside to observe outdoor conditions. 

Sensor is water resistant and is designed for general outdoor 

use, however, to extend its life place the sensor in an area 

protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or 

by using string (not included) to hang it from a suitable location, 

like a well covered tree branch. The best location is 4 to 8 feet 

above the ground with permanent shade and plenty of fresh air 

to circulate around the sensor.  

Important Placement Guidelines

• To ensure accurate temperature measurement, place units out of direct  

 

  sunlight and away from any heat sources or vents. 
• Display and outdoor sensor must be within 165 ft (50 m) of each other. 
• To maximize wireless range, place units away from large metallic items, thick  

  walls, metal surfaces, or other objects that may limit wireless communication.
• To prevent wireless interference, place both units at least 3 ft (.9 m) away    

  from electronic devices (TV, computer, microwave, radio, etc.).

Setup is Complete

The sensor will now synchronize with the display. It may take a few minutes for 

synchronization to complete. Please refer to the troubleshooting section of this 

manual if anything appears to be functioning improperly.

TV

3

(50 meters)

(165 feet maximum)

(.9 m)

AT

LEAST

APART

Содержание 00484

Страница 1: ...nstructions 2 Package Contents 2 Product Registration 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Set the Time Date Units 7 Backlight Settings 7 Pla...

Страница 2: ...rmance please read this manual in its entirety and retain it for future reference Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product Locate...

Страница 3: ...dicator 8 Date 9 Display Low Battery Indicator 10 Clock 11 Current Indoor Temperature Arrow icon indicates the direction temperature is trending 12 Humidity Level Indicator Indicates a high low or ide...

Страница 4: ...3 Button For alarm setup 4 RESET Button Full reset to factory defaults 5 Foldout Tabletop Stand 6 Battery Compartment 7 Plug in for Power Adapter 8 Battery Compartment Cover 9 Integrated Hang Hole Fo...

Страница 5: ...ires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4 F 20 C 1 Slide o...

Страница 6: ...g in the power adapter as the main power source for this product 1 2 2 Plug in Power Adapter PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOC...

Страница 7: ...F or C BAROMETRIC PRESSURE UNITS inHg or hPa You will automatically exit SETUP MODE if no buttons are pressed for 8 seconds Enter setup mode at any time by pressing the SET button Display Backlight Se...

Страница 8: ...ell covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate...

Страница 9: ...to 24 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint accuracy personalized for your exact location Depending on your model weather forecast icons will...

Страница 10: ...alarm value will be shown 4 Press and release the or buttons to adjust the alarm s HIGH value 5 Press and release the SET button The current LOW alarm value will be shown 6 Press and release the or bu...

Страница 11: ...mperature or humidity Make sure both the display and sensor are placed out of direct sunlight and away from any heat sources or vents see page 8 Make sure the display is positioned away from moisture...

Страница 12: ...least 5 seconds 2 Once in calibration mode the preference you are currently setting will be highlighted on the display 3 Press the or buttons to calibrate the data value higher or lower from the actu...

Страница 13: ...ss and release the SET button three times to enter barometric pressure calibration mode 4 Press the or buttons to calibrate the pressure higher or lower 5 Press the SET button to confirm the calibrati...

Страница 14: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 15: ...itation of incidental or consequential damages so the above limitation or exclusion may not apply to you We further disclaim liability from personal injury relating to our products to the extent permi...

Страница 16: ...AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 00506 INST 072717 It s more than accurate it s AcuRite offers an extensive assortment of precision instrume...