Cooling System
5. Remove the reserve tank from its
holder by pulling it straight up.
Drain the coolant, then put the
tank back in its holder.
6. When the coolant stops draining,
tighten the drain plug at the
bottom of the radiator. Put a new
washer on the drain bolt, then
reinstall the drain bolt in the
engine block. Tighten it securely.
Tightening torque:
58 Ibf.ft (78 N.m , 8.0 kgf.m)
7. Mix the recommended antifreeze
with an equal amount of purified
or distilled water in a clean
container. The cooling system
capacity is:
With 5-speed manual transmission:
(LS, GS)
1.16 US gal (4.4 l ,0.97 Imp gal)
(GS-R)
1.24 US gal (4.7 l ,1.03 Imp gal)
With automatic transmission:
1.24 US gal (4.7 l ,1.03 Imp gal)
8. Pour coolant into the radiator up
to the base of the filler neck.
9. Start the engine and let it run for
about 30 seconds. Then turn off
the engine.
CONTINUED
Maintenance
RESERVE TANK
RESERVE
TANK CAP
HOLDER
FILLER NECK
Fill up to here
Содержание Integra Sedan 2000
Страница 7: ...4...
Страница 91: ...88...
Страница 119: ...116...
Страница 133: ...130...
Страница 165: ...See Timing Belt on page 191 to determine need for replacement Maintenance...
Страница 167: ...Required Maintenance Record for Normal and Severe Schedules Maintenance...
Страница 221: ...218...
Страница 242: ...Fuses INTERIOR FUSE BOX CONTINUED Taking Care of the Unexpected...
Страница 243: ...Fuses UNDER HOOD FUSE BOX ABS FUSE BOX Taking Care of the Unexpected...
Страница 250: ...Specification s Technical Information page 239 page 240...