Acuity Brands Aculux AX3 A WDTW Скачать руководство пользователя страница 4

1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/aculux
©2017 Acuity Brands Lighting, Inc.     Rev 3/17     P6160

Product Services Phone (888) 387-2212

    

 4 of 5

INSTALLATION INSTRUCTIONS

DMX Downlight Installation

1. DMX Cable needs to meet the ANSI/TIA/EIA-485 standard for DMX-512 and have nominal characteristic impedance of 120 Ohms.
2. Termination resistors are included with each luminaire and should remain installed in the last luminaire of each run to prevent erratic network behavior.
3. No more than 30 fixtures may be installed on a single run.
4. No more than 1000 ft. of wire may be installed on a single run.
5. No T-TAPS, STARS (except by a DMX/RDM splitter), splices, or Ys allowed.
6. All fixtures intended to be controlled as a zone should be given the same DMX start address. Fixtures default to a start address of 1.
7. The following RDM configuration devices are recommended for fixture addressing and configuration
  a)  Acuity Controls Fresco DXT-1M12-2M09-NE1L and Pathport Manager 5.3 software
  b)  Fresco FCS7TSNX

DMX Installation Guide

Commissioning with Remote Device Manage (RDM)

After the fixtures are properly wired together as a DMX network (also known as a DMX universe):
1.
  Use an RDM controller (such as Fresco) that is compliant with ANSI E1.20 - 2010 Entertainment Technology RDM 

 

Remote Device Management Over DMX512 Networks requirements.

2.  Set the address(s) for the fixture(s) (addresses are also known as slots).
3.  Do not use other personalities before consulting with factory.
4.  After commissioning, do not operate the system with RDM and DMX messages at the same time.

Supported RDM PIDs
DMX-RDM PIDs 
Standard PID definition

Req

Get

Set

Aculux 
PID Implementation

Aculux Tunable White/BBD 
PID Implementation

Disc_Unique_Branch

Yes

Yes

Disc_Mute

Yes

Yes

Disc_Un_Mute

Yes

Yes

Supported_Parameters

Yes

Yes

Parameter_Description

Yes

Yes

Device_Info

Yes

Yes

Software_Version_Label

Yes

Yes

DMX_Start_Address

Yes

Yes

Yes

Identify_Device

Yes

Yes

Yes

Device_Model_Description

Yes

Aculux

Aculux BBD and Tunable White

Manufacturer_Label

Yes

Acuity Brands

Juno Lighting Group

Device_Label

Yes

Yes

Settable

Aculux IC/TC410T(SQ)

DMX_Personality

Yes

Yes

N/A

See Table of Personalities

DMX_Personality_Description

Yes

N/A

See Table of Personalities

Curve

Yes

Yes

Logarithmic and Linear,  
Preset to Logarithmic

N/A

Curve_Description

Yes

See note above

N/A

For TW/BBD Aculux only: 
Please use personality 2 for Black Body Dimming (BBD), also known as Warm Dimming, or personality 5 
for Tunable White (CCT Tuning). Consult with factory before using other personalities.
DMX-RDM 
Personalities 
Item

Personality

Slots

Slot 1 Handle

Slot 2 Handle

Description

2

Warm Dimming 
3000K SQ

1

Brightness

n.a.

BBD 1800-3000K, 
square law response

5

Tunable White 
4300K SQ

2

Brightness

CCT

CCT tuning 2000-4350K, 
square law response

Table 1:

Table 2:

DISCONTINUED

Содержание Aculux AX3 A WDTW

Страница 1: ...Only Install Fixtures and Controller Terminate Network Cables Plug Cables into Fixtures Aculux LED Fixture with DMX512 abbreviated here as DMX DMX Controller e g Fresco FCS7TSNX or similar RDM Configuration Device e g Fresco FCS7TSNX or DXT1M122M09NE1L DMX RDM Splitter Optional e g Fresco DXT1M122M09NE1L Twisted pair 120ohm shielded cable e g Belen 9842 or equal Termination Resistor Pre installed ...

Страница 2: ...ipment must be worn during all installation or servicing of the unit Do not touch individual electrical components as this can cause ESD shorten lamp life or alter performance All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with one of the following Part 15 of the FCC Rules Operation is subject to the following two ...

Страница 3: ...on resistor is installed into the last luminaire in each run as shown in Figure 4 Note Remove and discard pre installed termina tion resistor from all other fixtures 6 Use an RDM configuration device to discover fixtures and set DMX start addresses 7 Install DMX controller and connect to DMX cable 8 Configure controller according to Tables 1 2 on page 4 Termination Resistor plug directly into fixt...

Страница 4: ...anagement Over DMX512 Networks requirements 2 Set the address s for the fixture s addresses are also known as slots 3 Do not use other personalities before consulting with factory 4 After commissioning do not operate the system with RDM and DMX messages at the same time Supported RDM PIDs DMX RDM PIDs Standard PID definition Req Get Set Aculux PID Implementation Aculux Tunable White BBD PID Implem...

Страница 5: ...gnize the RDM protocol Termination resistor is used when you are using several DMX luminaires on a single DMX line Universe It removes noise and flickering on the DMX line which improves the reliability of the DMX system The termination resistor should match the cable impedance Square Law Curve is a dimming curve most closely correlating to that of traditional halogen dimming performance DMX Fail ...

Отзывы: