Acuity Brands Lighting 5BPMW LED Скачать руководство пользователя страница 2

 
 

Lithonia Downlighting  

 

Part No. 

CJ5201106

 

Rev. E

 

One Lithonia Way / Conyers, GA  30012

 

  

©20011 Acuity Brands Lighting, Inc., 12/11

 

800-315-4935 / www.lithonia.com 

 

 

Page 

2

 of 

5

 

 

INSTALLATION INSTRUCTIONS 

6BPMW LED (6” Baffle LED Module); 5BPMW LED (5” Baffle LED Module) 

4BPMW LED (4” Baffle LED Module)

 

Prior  to  installing  the  fixture,  disconnect  ALL  power  supplies  to  the  unit.  This  module  may  be  installed  in  TYPE  IC  or  NON-IC 
installations.  For TYPE NON-IC INSTALLATION ONLY:  No insulation may be placed over the top of or within 3” (76mm) of the 
fixture. 
 
INSTALLATION INSTRUCTIONS FOR 6BPMW LED AND 5BPMW LED 
 
Step 1: 6BPMW LED - Determine Mounting Method 

 

 
A.  Housing with torsion brackets (see Figure 1); use torsion springs to 

install LED module.   

 

 

Go to Step 2 – Grounding Wire 

 

B.  Housing without torsion brackets; use retention clips to install LED 

module.   

 

1.  Remove the springs (see Figure 2). 

2.  Select retention clip position (Figure 3).   

  Housing inside diameter 6.20” or less; use upper clip slots 

(Figure 4). Insert clips at the upper three slots (Figure 6). 

 

  Housing inside diameter 6.20” or more; use lower clip slots 

(Figure 5). Insert clips at the lower three slots (Figure 6). 

3.  Go to Step 2 – Grounding Wire 

 

 

 
 
 
 

 

 

If the retention clips are in the bottom position (see Figure 4), make sure there are no obstructions that will interfere with the clips 1” 

from the bottom of the recessed housing. 

 

 

If the retention clips are in the top position (see Figure 5), make sure there are no obstructions that will interfere with the clips within 2-

1/4” from the bottom of the recessed housing 

 
 
 
Step 1:  5BPMW LED - Determine Mounting Method

 

 
A.  Housing with torsion brackets (see Figure 1); use torsion springs to install LED module.   
 

 

Go to Step 2 – Grounding Wire  

 

B.  Housing without torsion brackets (see Figure 7); use retention 

clips to install LED module.   

 

1. 

Remove top cap screws and discard the torsion spring 
brackets.  

2. 

Insert three clips into upper slots. 

3. 

Go to Step 2 – Grounding Wire  

Existing Housing 

Figure 3 

Figure 6 

Figure 4 

Figure 5 

Figure 1 

Torsion  

brackets 

Torsion springs

 

Figure 2 

Top Cap Screws 

Figure 7 

Torsion 
Bracket 

Отзывы: