![Acucraft Outdoor Linear 8 Burner System Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/acucraft/outdoor-linear-8-burner-system/outdoor-linear-8-burner-system_installation-and-operators-manual_2844409019.webp)
19
PRODUCT SPECIFICATIONS
104 38 "
1"
1"
4 12 "
52 3
16 " INLET
2"
1"
3
8 "
1
2 "
3
8 "
CONNECTING TAB
1 18 "
GAS INLET
3/4"
2
3
1
REVISIONS
REV.
DESCRIPTION
ECO
DATE
ITEM NO.
PART NUMBER
DESCRIPTION
QTY.
1
0774-04
BURNER TRAY
1
2
0774-01
BURNER TUBE
1
3
0774-019
FLANGE
2
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
MATERIAL:
PROPRIETARY AND CONFIDENTIAL:
THE INFORMATION CONTAINED IN
THIS DRAWING IS THE SOLE
PROPERTY OF ACUCRAFT. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF ACUCRAFT IS
PROHIBITED.
5/2/2017
TITLE:
SIZE
B
DWG. NO.
REV
DATE:
R.SHEPHERD
DRAWN BY:
UNLESS
OTHERWISE
SPECIFIED ALL
DIMENSIONS
ARE IN INCHES
A
0774-C-001
END BURNER
DO NOT SCALE DRAWING
SHEET 1
OF 1
Acucraft Fireplace Systems
19672 172nd Street
Big Lake, MN 55309
Page 6
19
SPECIFICATIONS
Depth = 2 1/2”
Length = 138 1/2”
Width = 4 1/2”
Appx Weight. = 200 lbs.
Gas Type = Natural Gas
Electrical = Single 15 AMP service
NATURAL GAS
Input Rating (BTU/hr) 0-1370 m = 125,000 BTUs/hr.
Minimum inlet pressure (in.w.c.) = 7.0 in. W.C.
Maximum inlet pressure (in.w.c.) = 10.5 in. W.C.
Based on testing that was performed,
the following results have been re-
corded.
Minimum Clearances to combustibles
Unit to back wall of enclosure = 4 feet
Unit to sidewall of enclosure = 4 feet
Unit top to enclosure top = 8 feet