Care & Maintenance

Display Unit Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep 

away from dust, dirt and moisture. Clean ventilation ports regularly with a 

gentle puff of air.

Outdoor Sensor Care

Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.

Calibration

The indoor / outdoor temperature and humidity readings, and barometric 

pressure can be calibrated on the display unit to improve accuracy. Calibration 

can improve accuracy when sensor placement or environmental factors impact 

the data accuracy.
1. To access calibration mode, press AND HOLD the “ “, “ ”, and “ “ 

buttons simultaneously for at least 5 seconds.

2. To adjust the currently selected (flashing) item, press and release the “ “ 

or “ “ buttons to calibrate the data value higher or lower from the actual 

reading.

3. To save your adjustments, press and release the “ ” button to adjust the 

next preference. The “ ” icon will remain illuminated next to calibrated 

values.

  The preference set order is as follows:
  OUTDOOR TEMPERATURE 

OUTDOOR HUMIDITY 

INDOOR TEMPERATURE 

INDOOR HUMIDITY 

BAROMETRIC PRESSURE  (must be set to MANUAL mode to calibrate)*

  *To change from AUTO to MANUAL pressure mode and vice versa, press 

AND HOLD the “ ” button for 5-7 seconds. The “ ” icon will appear 

next to the barometric pressure to indicate that MANUAL mode has been 

activated. Press and HOLD the “ ” button for 5-7 seconds to return to 

AUTO mode. 

After 20 seconds of inactivity, the display will save the adjustments and exit 

calibration mode. Note: Calibrations will be erased if the display is reset or if 

batteries are removed and the power adapter is unplugged. 

Содержание 75108SBDI

Страница 1: ...duct Registration 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Set the Time Date Units 7 Backlight Settings 7 Placement Guidelines 8 Using the Weathe...

Страница 2: ...th Tabletop Stand 2 Outdoor Sensor 3 Power Adapter 4 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED...

Страница 3: ...and Buttons For setup preferences 11 Button For setup preferences 12 Button For alarm setup 13 Date 14 Moon Phase 15 Humidity Level Indicator Indicates a high low or ideal humidity comfort level 16 Ba...

Страница 4: ...tegrated Hang Holes For easy wall mounting 3 Battery Compartment 4 A B C Switch ID code that must match sensor s A B C switch to ensure units synchronize 5 Plug in for Power Adapter 6 Battery Compartm...

Страница 5: ...echargeable batteries are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batterie...

Страница 6: ...ble batteries DO NOT short circuit the supply terminals IMPORTANT Batteries are a backup power source to preserve records in the event of a power outage Power adapter is recommended as the primary pow...

Страница 7: ...Daylight Saving Time You will automatically exit SET MODE if no buttons are pressed for 10 seconds Enter setup mode at any time by pressing the button Display Backlight Settings This weather station...

Страница 8: ...ocation like a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To...

Страница 9: ...unar phase icons Barometric Pressure Subtle variations in barometric pressure greatly affect the weather This weather station displays the current pressure with an arrow icon to indicate the direction...

Страница 10: ...be shown 2 Press and release the or buttons until appears 3 Press and release the button The current HIGH alarm value will be shown 3 Press and release the or buttons to adjust the alarm s HIGH value...

Страница 11: ...e display and an electrical outlet Outdoor temperature is flashing or showing dashes Flashing of the outdoor temperature is generally an indication of wireless interference 1 Bring both the sensor and...

Страница 12: ...ess and release the or buttons to calibrate the data value higher or lower from the actual reading 3 To save your adjustments press and release the button to adjust the next preference The icon will r...

Страница 13: ...rsuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate r...

Страница 14: ...IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ALL OTHER WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY EXPRESSLY DI...

Страница 15: ...15...

Страница 16: ...cuRite uses patented technology Visit www AcuRite com patents for details Printed in China 75108SBDI INST 030216 It s more than accurate it s AcuRite offers an extensive assortment of precision instru...

Отзывы: