background image

10

Troubleshooting

Problem

Possible Solution

No outdoor sensor

reception

no bars

If the wireless signal indicator shows no bars:
•  Relocate the display unit and/or the outdoor sensor. The 

units must be within 330 ft (100 m) of each other.

•  Make sure both units are placed at least 3 feet  

(.9 m) away from electronics that may interfere with 

the wireless communication (such as TVs, microwaves, 

computers, etc).  

•  Use standard alkaline batteries (or lithium batteries in 

sensor when temperature is below -4ºF/-20ºC). Do not 

use heavy duty or rechargeable batteries. NOTE: It 

may take up to 20 minutes for display unit and sensor to 

synchronize after batteries are replaced. 

Outdoor 

 temperature

is flashing or   

showing dashes

Flashing of the outdoor temperature is generally an 

indication of wireless interference. 

1.  Bring both the sensor and display unit indoors and 

remove batteries from each.

2. Make sure the A-B-C switch on both units match.
3. Reinstall batteries in the outdoor sensor. 
4. Reinstall batteries in the display unit.
5.  Let the units sit within a couple feet of each other 

for about 20 minutes to gain a strong connection. 

Sometimes changing to a different channel can help. 

Inaccurate forecast

•  Weather Forecast icon predicts conditions for the next 12 

to 24 hours, not current conditions.

•  Has Learning Mode icon disappeared from the display 

unit? Learning Mode must complete before forecast and 

pressure will be accurate.

•  Allow unit to run continuously for 33 days. Battery 

removal or resetting the display unit will restart Learning 

Mode. After 14 days, forecast should be fairly accurate, 

however Learning Mode calibrates for a total of 33 

days.

Inaccurate

temperature  

or humidity

•  

Make sure both the display unit and sensor are placed 

out of direct sunlight and away from any heat sources or 

vents (see page 8).

•  Make sure both units are positioned away from moisture 

sources (see page 8). 

Содержание 02030RM

Страница 1: ...2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Intelli Time Clock 7 Set the Time Date Units 7 Backlight Settings 7 Placement Guidelines 8 Using the Weather Station 9 Troubleshooting 10 Care Maintenance 12 Calibration 12 Replace Intelli Time Battery 13 Specifications 14 FCC Information 14 Customer Support 15 Warranty 15 Weather Station models 02030RM...

Страница 2: ... with tabletop stand 2 Outdoor sensor 3 Instruction Manual 4 Power adapter PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Features Benefits 4 3 2 1 5 OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 Wireless Signal Indicator Flashes when data is being sent to the d...

Страница 3: ...umidity 7 Current Indoor Temperature 8 Moon Phase 9 Auto Icon Indicates display backlight AUTO DIM mode activated 10 Day of the Week 11 Display Low Battery Indicator 12 Date 13 Time 14 Current Barometric Pressure Arrow icon indicates the direction pressure is trending 15 12 to 24 Hour Weather Forecaster Self Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forec...

Страница 4: ...references 4 Button for setup preferences 5 A B C Switch ID code that must match sensor s A B C switch to ensure units synchronize 6 Reset Full reset to factory defaults 7 Plug in For Power Adapter 8 Battery Compartment 9 Intelli Time Battery Compartment 10 Battery Compartment Cover 2 1 3 4 5 6 7 8 9 10 Features Benefits ...

Страница 5: ... rechargeable batteries are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartment 2 Insert 2 x AA batteries into the batt...

Страница 6: ...ries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize Install or Replace Backup Batteries optional 1 Remove the batte...

Страница 7: ...R TEMPERATURE SCALE ºF or ºC BAROMETRIC PRESSURE SCALE inHg or hPa If you live in an area that observes daylight saving time DST should be set to ON even if it is not currently Daylight Savings Time You will automatically exit SETUP MODE if no buttons are pressed for 20 seconds Enter setup mode at any time by pressing the SET button Display Backlight Settings This weather station s color display f...

Страница 8: ...e a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any heat sources or vents Display unit and outdoor sensor must be within 330 ft 100 m of each other To maximize wireless r...

Страница 9: ...the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISING Moon Phase Track the phases of the moon conveyed through simple lunar phase icons High Low Records Today s high and low records are displayed for indoor and outdoor temperature and humidity Today s records automatically clear at 12 00am midnight every day View today s high or low rec...

Страница 10: ...doors and remove batteries from each 2 Make sure the A B C switch on both units match 3 Reinstall batteries in the outdoor sensor 4 Reinstall batteries in the display unit 5 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Sometimes changing to a different channel can help Inaccurate forecast Weather Forecast icon predicts conditions for the nex...

Страница 11: ... that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset The unit lost power or batteries were changed and the time is not correct The Intelli Time battery needs to be replaced see page 13 Once the new battery is installed time and date wil...

Страница 12: ... the or buttons to calibrate the data value higher or lower from the actual reading 4 Press the Set button to confirm the calibration adjustment The icon will remain illuminated next to calibrated values 5 The next adjustable data will begin flashing indicating it is ready to be calibrated Repeat Steps 1 4 to calibrate additional data After 20 seconds of inactivity the display will save the adjust...

Страница 13: ...tery compartment as shown Install battery with positive terminal facing OUT 3 Screw in the battery cover 3 Press the or buttons to calibrate the pressure higher or lower 4 Press the Set button to confirm the calibration adjustment Note The icon will remain illuminated next to the calibrated value After 20 seconds of inactivity the display will save your adjustments and exit calibration mode Note C...

Страница 14: ...on This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turn...

Страница 15: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Страница 16: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 02030 INST 092314 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers C...