ACTUS 720 Series Скачать руководство пользователя страница 2

 

245 East Roselawn Ave, Suite 23  .  St. Paul  MN  55117 

Main 651.487.8716  .  Fax 651.487.4173 

www.ACTUSINC.com 

4.

 

Before connecting the linkage, run unit back and forth to make sure 
that the stroke of the actuator matches that of the lever to be moved.  
If the stroke of the actuator needs to be adjusted, proceed as follows: 

 

a.

 

Run unit back and forth and note how the adjustment pins 
contact the limit switches to set the stroke length. 

 

NOTE 
Before attempting any adjustment of the limit switches, 
turn the power off to prevent any accidental short circuits 
or injury. 

 

b.

 

Determine which limit switches must be adjusted.  Loosen the 
set screws, with the Allen wrench supplied, and slide the pins in 
or out to adjust the stroke as needed.  Do not over tighten set 
screws. 

 

CAUTION 
Do not attempt to adjust the stroke by bending the 
contacts on the limit switches.  This is the most frequent 
mistake which causes failure of the limit switches and 
inevitable failure of the entire unit. 

 

5.

 

With the proper stroke set, connect linkage to lever and run unit back 
and forth to make sure that the actuator runs freely without any 
binding. 

 

NOTE 
Be sure that the actuator contacts the limit switch before 
reaching the end of its mechanical stroke.  Failure to do so 
could result in damage to the actuator. 

 

6.

 

Replace actuator cover. 

 
7.

 

Ready to begin operation. 

 

Содержание 720 Series

Страница 1: ...iagram All frame grounds should be free of corrosion paint and dirt Wires shown running direct to the negative post of the battery should be attached there or to a similar good direct ground Frame grounding is not recommended for these wires Note that this actuator is grounded with terminal 3 Terminals 4 and 5 provide bi directional motor control c This is a negative ground 12 or 24 VDC system Be ...

Страница 2: ...ermine which limit switches must be adjusted Loosen the set screws with the Allen wrench supplied and slide the pins in or out to adjust the stroke as needed Do not over tighten set screws CAUTION Do not attempt to adjust the stroke by bending the contacts on the limit switches This is the most frequent mistake which causes failure of the limit switches and inevitable failure of the entire unit 5 ...

Страница 3: ...s the terminal block 1 Take a small flat blade screw driver and insert it into the slot above where you want the wire to go 2 Press down 3 As you continue to press down push the screwdriver towards the housing and the terminal block will open ...

Страница 4: ...all ground wires as shown on the wiring diagram All frame grounds should be free of corrosion paint and dirt Wires shown running directly to the negative post of the battery should be attached to a similar good direct ground Frame grounding is not recommended for these wires Note that this actuator is grounded with terminal 3 Terminals 4 and 5 provide bidirectional motor control Improper ground wi...

Страница 5: ...e actuator may run to either the fully retracted or extended position limit switch then stop It is rare that the pot will fail but it can be easily checked with an ohmmeter 10 Place the probes of the ohmmeter across the ORANGE and BROWN wires A reading of approximately 2000 ohms should be read 11 Place the probes of the ohmmeter across the ORANGE and YELLOW wires Run the actuator back and forth as...

Страница 6: ... on the BLACK wire 14 To retract the actuator place 12 volts on the BLACK wire ground on the RED wire 15 If the actuator operates as described the problem points to the limit switches The switches can only be replaced by ordering a complete P C board Actus part number 024 0576 024 0577 P C board with feedback pot If the motor will not operate it must be replaced ...

Страница 7: ...720 Actuator Wiring Diagram 245 East Roselawn Ave Suite 23 St Paul MN 55117 Main 651 487 8716 Fax 651 487 4173 www ACTUSINC com ...

Отзывы: