Actulux 111735 Скачать руководство пользователя страница 9

9

Room Thermostat

automatic opening and closing of skylights and windows

AUTOMATIC OPENING AND CLOSING OF SKYLIGHTS

The room thermostat can be used for automatic opening 

and closing of skylights when the temperature in the room 

exceeds the set temperature. There is approx. 1 degree 

between the open and close limit.

The room thermostat is often connected with an 

AUT-MAN switch so the opening can be controlled 

automatically or manually.

The room thermostat can also be connected with a 

weekly timer which makes sure that the window is closed 

automatically, e.g. during the night. Should be used 

together with a weather sensor in order to protect against 

opening in bad weather.

Dimensions: 75 x 75 x 25 mm

Colour: White

#111778

Содержание 111735

Страница 1: ...1 Chain drives Kædemotorer Kettenantrieben Accessories Opérateurs de la chaîne ...

Страница 2: ... Current Limiter and Overload Interrupter 13 LIP7 Current Limiter and Overload Interrupter 14 Flex1 ACDC AC Power Supply for LIP or Chain Motor 15 GSM Modem Module for Control Panels 16 Add On Relay PCB for indication of window position 17 Alarm Failure Add on Relay PCB for SV control panels 18 Actulux offers a wide range of accessories for electrical control panels and opening systems Accessories...

Страница 3: ...sor Fire Switch BVT IP40 Actulux Products Smoke Detector Heat Detector Remote Control Room Detector LIP5 LIP6 Add On Relay PCB Flex1 GSM Modem Comfort Switch OPUS FUGA HOC LIP7 Alarm Failure Add On Relay PCB Fire Switch BVSA IP65 ...

Страница 4: ...ass and activate the red button During test open the lid and activate the red button Closing and alarm reset Open the lid activate the black reset button alarm is reset and skylights are closed Connection diagram for BVT Terminals 1 green LED OK lights when closing 2 Yellow LED lights on error 3 red LED alarm lights on emergency opening 4 ground 5 6 fire switch emergency closing reset 7 fire switc...

Страница 5: ...rey Protection degree IP65 Item no 111626 EASY INSTALLATION AND OPERATION The fire switch is delivered in a IP65 box for e g outdoor installation and is developed to be used together with the Actulux smoke ventilation system Connection diagram for BVSA 111626 Ω Ω 2 6 4 13 15 11 Terminals 2 green LED OK lights when OK and while closing 6 yellow LED lights on error 4 red LED alarm emergency opening ...

Страница 6: ...Actulux Flex1 ACDC using a RF transmitter 111892 fitted into the sensor Range Line of sight approx 400 meters Actulux Control Panels have to be equipped with RF receiver PCB 111894 for SVM Control Panels 111895 for SV Control Panels FEATURES Power supply 18V til 35VAC 20V til 35VDC 200V til 250VAC Output contact NO NC 1 x potential free change over contact Contact rating 250VAC 8A or 24VDC 8A Dime...

Страница 7: ...tulux Weather Sensor wireless to Actulux SV SVM Control Panel or to Actulux Flex1 ACDC using a RF transmitter 111892 fitted into the weather sensor Range Line of sight approx 400 meter Remote Control wireless comfort control FEATURES Battery 12V 33 mAH type LRV08L Battery lifetime app 2000 of 1 sec operate function One receiver can memorize maximum 20 transmitters remote controls Carrier frequency...

Страница 8: ...l blau rot Blå Rød L1 L2 L1 L2 L1 IN OUT L1 L2 L1 IN OUT CH WindowMaster AG 062 289 22 22 D WindowMaster Fenstertechnik GmbH 040 54 73 85 85 GB WindowMaster Control Systems Limited 01 536 510 990 Head office WindowMaster A S 45 45 67 03 00 Skelstedet 13 2950 Vedb k Denmark æ www WindowMaster com Første automatiske melder Tilslutning til brandcentral Varmedifferential melder WSA 310 Apollo 55000 12...

Страница 9: ...ere is approx 1 degree between the open and close limit The room thermostat is often connected with an AUT MAN switch so the opening can be controlled automatically or manually The room thermostat can also be connected with a weekly timer which makes sure that the window is closed automatically e g during the night Should be used together with a weather sensor in order to protect against opening i...

Страница 10: ...nting Dimensions 65 x 65 x 45 mm Please remember to mount return springs behind both arrow keys Comfort Switch Type FUGA manual control of comfort ventilation MANUAL CONTROL OF COMFORT VENTILATION Up down switch for manual control of comfort ventilation e g in connection with 24V fire and smoke ventilation systems The up down switch is delivered with housing for wall mounting Dimensions 50 x 50 x ...

Страница 11: ...th 3 generation of Actulux chain drives FEATURES Power Supply 24 36 48VDC 15 Max Ripple 2 Volt PP Max power in the position relay 30VDC 2A Dimensions L x W x D 86 x 86 x 39 mm Colour White Density IP65 Meets requirements EN12101 2 EN60335 1 EN50130 4 Marking CE Product number 390420 Standard 390421 BMS 0 10V control INPUT STROKE LENGTH INDICATION FOR OPEN CLOSE EXTERNAL CONTROL 0 10V 0 100 stroke ...

Страница 12: ...ely because of a mechanic locking or end stop LIP5 is delivered in a discreet plastic box which also functions as a link between the supply and the actuator FEATURES Supply 24V DC eller 48V DC 15 Ripple 2 Volt PP Current limiter Adjustment possibilities for max current consumption by means of a switch on the board Type of opening system 24V 48V SA Power 3 0A 1 5A SA Power 4 0A 2 0A SA Power Mini 2...

Страница 13: ...s as a link between the supply and the actuator s FEATURES Supply 24VDC or 48VDC 15 Output 2 outputs which can function independently individually in single operation or or in joint operation tandem Current limiter Adjustment possibilities for max current consumption by means of a switch on the board Type of opening system 24V 48V SA Power 3 0A 1 5A for each actuator output SA Power 4 0A 2 0A for ...

Страница 14: ...or skylight Open Close indication and Synchro mode requires that the electrical actuators in the opening system is mounted with reed switches for speed position indication LIP7 TA tandem 121306 LIP7 OC open close 121308 LIP7 BA basis 121305 FEATURES Power supply 24 36 48 VDC 15 Max Ripple 2 Volt PP Input resistance Using switch on the PCB a 27kΩ resistor can be engaged over the input terminals of ...

Страница 15: ...Comfort Switch OPUS part no 111753 Actulux A S Denmark DK 9560 Hadsund Haandvaerkervej 2 www actulux com Phone int 45 98 57 40 90 Fax int 45 96 15 28 00 e mail info actulux com ON 1 318001504230 N NEUTRAL 2 HCV Sync 1 UP LipX AC R 1 Brown To be cut if DCR is going to be used Mount 111894 Jumper Blu e Blue Sync 2 1 2 Red Neutral Earth PD DOWN HCM White PD HCM without LIP Grey Phase if mounted PE EA...

Страница 16: ...odule for new and existing installations This GSM Modem texts a pre defined mobile no if one of the inputs is activated The unit is intended for information about e g an open roof light and other relevant information The unit is not to be considered as an alerting system in case of fire but solely as an information unit The installation is simple as the unit only needs to be connected to the fail ...

Страница 17: ...unction is needed The Add on relay PCB is going to be connected through a flat cable to the SV control unit and the indication LED display in the front FEATURES Supply 24V DC Contact function 2 pcs NO NC contacts Load on contacts 230V 2A LED1 LED2 Indication about open Can also be used for indication of active weather sensor requires special software in control panel Part no 111690 SV Control Pane...

Страница 18: ...ED2 Indication of relays ON OFF Part no 111930 SV Control panel Add on Relay onn diagram extra Alarm 122006 11968 reen 3A Violet ON or or LD1 Aktuator 1 åben rød Lyser når aktuator 1 åbner LD2 Aktuator 1 lukke grøn Lyser når aktuator 1 lukker LD3 Aktuator 2 åben rød Lyser når aktuator 2 åbner LD4 Aktuator 2 lukke grøn Lyser når aktuator 2 lukker LD5 Vejrsensor aktiv rød Lyser ved aktiv vejrsensor ...

Страница 19: ...19 Notes ...

Страница 20: ...20 06 01 2020 ...

Отзывы: