1.     Wired remote controller dimensions

3. Installation Method

Wired Remote Controller

Fig 3.1

Содержание WC-02

Страница 1: ...ling or operating your wired remote controller Make sure to save this manual for future reference Copy Follow me Back Turbo Confirm Day off Del Timer Swing OWNER S MANUAL INSTALLATION Universal Wired Remote Controller Model Number WC 02 That s better That s Actron ...

Страница 2: ...fication 10 5 Wired Controller Features and Functions 11 6 Wired Controller Display 12 7 Wired Controller Buttons 13 8 Preparatory Operation 14 9 Operation 15 10 Timer Functions 20 11 Weekly Timer 23 12 Fault Alarm Handing 30 Table of Contents Installation and Owner s Manual Page 2 ...

Страница 3: ...escription of the precautions that should be brought to your attention during operation To ensure the correct service of the wired controller read this manual carefully before using the unit Keep this manual after reading for future reference This manual is a controlled document which contains confidential and proprietary information Distribution modification copying and or reproduction are prohib...

Страница 4: ...wiring as damage to wired controller will result Maintain correct separations between ELV wiring and other 230VAC mains wiring 3 The shielded wire of the wired controller must be properly grounded see wiring diagram 4 Upon finalising the wired controller connection do not use an ohmmegger test to check the insulation No Name Qty Remarks 1 Wired controller 1 2 Installation and owner s manual 1 3 Sc...

Страница 5: ...Page 5 1 Wired remote controller dimensions 3 Installation Method Wired Remote Controller Fig 3 1 ...

Страница 6: ...rminal of the longer connection cable See Fig 3 3 2 3 Connect the four wires to each of the pins in the multi function board as follows The red wire on wire controller connect to 12 5V pin on multi function board black wire to E pin yellow wire to Y pin brown wire to X pin See Fig 3 3 1 Fig 3 3 2 Fig 3 3 1 When connecting to 4 core wired controller 12V Red E Black Y Yellow X Brown 3 Installation M...

Страница 7: ... controller Fig 3 4 Fig 3 4 NOTE The PCB is mounted in the upper part of the wired controller Be careful not to damage the board with the screwdriver NOTE Place on a flat surface Be careful not to distort the wire controller s back plate by over tightening the mounting screws 5 Fasten the wire controller back plate For surface mounting fasten the back plate on the wall with the 3 screws M4x20 and ...

Страница 8: ...power is restored and the displayed time is not correct replace the battery There are three methods 1 from the rear 2 from the bottom 3 from the top 4 Notch the part for the wiring to pass through with a nipper tool 6 Battery installation 3 Installation Method Wired Remote Controller Fig 3 7 Fig 3 8 7 Wiring the indoor unit 3 1 2 NOTE DO NOT allow water to enter the remote control Use a water loop...

Страница 9: ...9 8 Reattach the wire controller s upper part While adjusting and mounting the upper case avoid clamping the wiring during installation Fig 3 9 IMPORTANT All the pictures in this manual are for illustration purposes only Your wire controller may differ slightly ...

Страница 10: ...ications 4 Specification Wired Remote Controller Input Voltage DC 12V Ambient Temperature 5ºC 43ºC Ambient Humidity RH40 RH90 Wiring Type Size Total Length Shielded PVC or cable 0 75mm2 20m 1 5mm2 50m Wiring Specifications ...

Страница 11: ...splay displays the error code helpful for servicing 4 way wire layout design Room temperature display Weekly Timer Function Mode choose Auto Cool Dry Heat Fan Fan speed Auto Low Med High Swing on Wall Split and Cassettes Timer ON OFF Temp setting Weekly Timer Follow me Child Lock LCD Display Clock Elevating Panel Function on Cassettes only ...

Страница 12: ...t swing indicator 4 Up down swing indicator 5 Elevating Panel Function indicator 6 Main unit and secondary unit indicator 7 Follow me function indicator 8 Turbo Auxiliary Heat function indicator 9 C indicator 10 Temperature display 11 Lock indicator 12 Room temperature indicator 13 Clock display 14 On Off timer 15 Timer display ...

Страница 13: ...Page 13 Wired Controller Buttons 7 Buttons Wired Remote Controller 1 Mode 2 Power 3 Adjust 4 Fan Speed 5 Swing 6 Timer 7 Day Off Del 8 Copy Follow me 9 Back Turbo 10 Confirm ...

Страница 14: ...dy after pressing TIMER or if nothing is pressed in 10 seconds 4 Press or to set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time 5 The setting is complete after pressing TIMER or if no button is pressed for 10 seconds Set the current Day and Time 8 Preparatory Operation Wired Remote Controller ...

Страница 15: ...The Operation Mode operating mode setting Room Temperature Setting 9 Operation Wired Remote Controller Press the Power Button Press MODE to set the operation mode Press or to set the room temperature Indoor Setting Temperature Range 17 30 C ...

Страница 16: ...the room temperature is detected at the indoor unit or at the wired controller NOTE When the FOLLOW ME function indication appears the room temperature is detected at the wire remote controller Child Lock Function Press LOCK for 3 seconds to activate the CHILD LOCK feature and lock all buttons on the wired controller Press again for 3 seconds to deactivate NOTE When the child lock function is acti...

Страница 17: ... heating process Elevating Panel Function only for Cassette models 1 When the unit is off Press the MODE button long to activate the lift panel function The mark will flash 2 Press the button and to control the lift and drop of the panel Pressing the button can stop the panel while it is dropping Pressing the button can stop the panel while it is lifting Keypad Tone Setting Press SWING and TIMER s...

Страница 18: ...he following instructions for the unit with four Up Down louvres can be operated individually 1 Press the SWING button to activate the Up Down adjusting louvre function The mark will flash Not applicable to all the models 2 Pressing the button or can select the movement of four louvres Each time you push the button the wire controller select in a sequence that goes from the icon means the four lou...

Страница 19: ...When the Up Down swing function is activated the mark appears 2 Left Right swing Press the Swing button long to start Left Right swing function Press it again to stop When the Left Right swing function is activated the mark appears 9 Operation Wired Remote Controller Swing Function for Wall Split models ...

Страница 20: ... The timer operates and the air conditioner operation starts after the time has passed Off Timer Use to stop the air conditioner operation The timer operates and the air conditioner operation stops after the time has passed On and Off Timer Use to start and stop the air conditioner operation The timer operates and the air conditioner operation starts and stops after the time has passed ...

Страница 21: ...ctions Wired Remote Controller 1 Press Timer to select the or button 2 Press Confirm and the Clock display flashes 3 Press or to set the time After the time is set the timer starts or stops automatically 4 Press Confirm again to finish the settings ...

Страница 22: ...ns Wired Remote Controller 1 Press Timer to select the button 2 Press Confirm and the Clock display flashes 3 Press the button or to set the On Timer and then press Confirm 4 Press the button or to set the Off Timer 5 Press Confirm to finish the setting ...

Страница 23: ...week and then press Confirm Press the button or to select the setting time The setting time mode temperature and fan speed appear on the LCD Press Confirm to enter the setting time process 1 Weekly Timer Setting 2 Day Of The Week Setting 3 Event timer setting 11 Weekly Timer Wired Remote Controller ...

Страница 24: ... 8 Press and to set the operation mode then press Confirm Press and to set the room temperature then press Confirm NOTE This setting is unavailable in the FAN or OFF modes 5 Operation Mode Setting 6 Room Temperature Setting IMPORTANT Up to 8 scheduled events can be set on one day Various events can be scheduled in either MODE TEMPERATURE and FAN speeds ...

Страница 25: ...irm Different scheduled events can be set by repeating steps 3 through 7 Additional days in a one week period can be set by repeating steps 3 through 8 NOTE The weekly timer setting can be returned to the previous step by pressing BACK The current setting is restored The controller will not save the weekly timer settings if there is no operation within 30 seconds 8 Off Mode Setting 9 Different Sch...

Страница 26: ...wer to cancel the timer mode The timer mode can also be cancelled by changing the timer mode using Timer 1 After setting the weekly timer press Confirm 2 Press or to select the day of the week 11 Weekly Timer Wired Remote Controller To Start To Cancel To Set The Day Off for a holiday ...

Страница 27: ...e set day has passed Copy out the setting in one day into the other day A scheduled event made once can be copied to another day of the week The scheduled events of the selected day of the week will be copied The effective use of the copy mode ensures the ease of reservation making 1 In the weekly timer press Confirm 2 Press or to select the day to copy from To Create An Off Day To Create An Off D...

Страница 28: ...he letters CY appear on the LCD 4 Press or to select the day to copy to 4 Press or to select the day to copy to 5 Press COPY to confirm The mark flashes quickly 6 Other days can be copied by repeating steps 4 and 5 7 Press Confirm to confirm the settings 8 Press BACK to revert to the weekly timer ...

Страница 29: ...During the weekly timer setting press Confirm 2 Press and to select the day of the week and then press Confirm 3 Press and to select the setting time want to delete The setting time mode temperature and fan speed appear on the LCD The setting time mode temperature and fan speed can be deleted by pressing the DEL day off ...

Страница 30: ...nsor malfunction E4 T2B sensor malfunction E5 T3 or T3 or TP sensor malfunction E6 Zero check malfunction E7 Indoor EERROM malfunction E8 Fan controller out of control E9 Communication malfunction between main PCB and display board EA Compressor overload 4 times EB IPM mould malfunction EC Air clean malfunction ED Outdoor malfunction protection EE Full water malfunction EF Other fault P0 Evaporato...

Страница 31: ...ses P4 Discharge pipe temperature protection P5 Discharge high pressure protection P6 Discharge low pressure protection P7 Over voltage protection P8 Compressor overload protection P9 Reserve code PA Reserve code PB Reserve code PC Reserve code PD Reserve code PE Reserve code PF Other fault 12 Fault Alarm Handling Wired Remote Controller ...

Страница 32: ...actronair com au 1300 522 722 Copyright 2016 Actron Engineering Pty Limited ABN 34 002 767 240 Registered Trade Marks of Actron Engineering Pty Limited Document 9590 4002 Ver 6 Issue Date 03 2019 ...