background image

 

 

9

ActronConnect Installation & Commissioning Guide - Website

Doc. No.9590-1001  Version No.3.0  150901C   

Step 1.2.2.

 Do not place the ActronConnect module where it can be easily damaged by accidentally 

stepping on it or where it can be covered by ceiling insulation.

Step 1.2.3.

 Refer to the module mounting diagram - Requirements for ACM Optimum Signal Performance, 

for the best mounting direction of the module based on your particular installation requirement.

Step 1.2.4.

 Refer to the wiring diagram for the cable connections on pages 29 - 33.

Step 1.2.5.

 Take the ActronConnect module 3m Grey Data Cable running from the indoor electrical panel 

& run it to the installed module, ensuring it is in a position where it cannot be easily damaged and it is at 
least 300mm away from any other installed cables (i.e. power, lights, PC data, TV antenna, etc.). If it is 
impossible to avoid running the ACM data cable close to the other cables, run it across the other cables 
at 90 degree (do not run in parallel).

           

Run the ACM data 

cable from the Indoor 

Unit to the ACM

3m ACM

Data Cable from the 

Indoor Unit

ActronConnect 

Module

Step 1.2.6.

 Secure the 3m Grey Data Cable to the timber roof joist or similar with the cable ties or other 

suitable cable fi xing fasteners. Do not loop any excess cable in a tight loop. Leave it loose.

   

Strong possibility of communication problems.

The “

loops

” can cause an electro-magnetic 

interference, upsetting data communication.

No electro-magnetic interference.

Keep communication cable at least 300mm 
from high voltage cables.

Do 

NOT

 loop excess cable  

RUN

 data cable as straight 

and short as possible 

NOT RECOMMENDED

RECOMMENDED

Содержание ACM-1

Страница 1: ...information Distribution modification copying and or reproduction are prohibited without written consent from ActronAir Please Read This Guide Congratulations on your purchase of an ActronConnect Module This unit has been designed and manufactured with the highest quality standard in mind Please read this guide thoroughly and keep it in a safe place for future reference ActronConnect Module ACM 1 ...

Страница 2: ...hipment Inspect the module components and accessories for any sign of shipping damage If there is any damage to the contents contact ActronAir Customer Care Department immediately on 1300 135 995 Make certain that the ActronConnect module is compatible with the ActronAir air conditioning system you plan to install it on See FAQs about the product Take time to thoroughly read the installation commi...

Страница 3: ...otocol 802 11b g n Operating System Requirement IOS 6 1 3 or later version Security Protocol Web 128 WPA PSK WPA2 PSK Hardware Voltage 9VDC 15 VDC Max Operating Temperature 60o C IP Rating IP20 Max Cable Length from ACM to Power Supply Kit 10 metres Access Point Distance 15 metres Wi Fi Range 70m line of sight The maximum distance that can be established between ACM and mobile device i e iphone ip...

Страница 4: ...Panel base Ensure that the earth ring terminal is pointing towards the right side looking at the electrical panel Power Supply Kit Pre wired Supplied PLUG C RJ45 Data Cable to ActronConnect Module Ensure the power supply ventilation holes are NOT covered by the excess cables or other foreign matter Option 2 Using the Double Sided Tape Double Sided Tape Power Supply Kit Pre wired Supplied PLUG C RJ...

Страница 5: ... pushing it all the way in Unplug Ultima 2 Pin Power Connector from P1 and connect PLUG A as in Step 5A above Then plug the Ultima power connector into the auxiliary power socket Step 1 1 6 Connect EARTH RING LUG to the earthing bolt of the indoor unit electrical panel Unscrew the nut remove the washer slide the EARTH RING LUG over the bolt making sure all of the existing earthing lugs remain conn...

Страница 6: ... cable to the electrical panel and into the zone cables exiting from the same cable gland Large Cable Gland Run the ACM data cable out from the electrical panel NOTE For optimum performance module communication integrity keep the ActronConnect Module data cable as far as possible from the 230VAC mains Step 1 1 9 Take the wiring diagram with adhesive back peel off adhesive protection strip stick th...

Страница 7: ... keep 300mm minimum distance from other cables mains data antenna etc 2 DO NOT USE Actron CAT5E zone cables to extend ACM cables 3 Locate the ActronConnect Module as close as possible to the ceiling and the manhole for ease of access ensuring that LED is facing towards the manhole and that the roof insulation does not come into contact with the module 4 Do not install ActronConnect Module in roof ...

Страница 8: ...structure or objects Do not locate the module where the signal will be blocked by any large metal concrete structure or objects with high water content People animals and plants are composed mostly of water Make sure that these do with high water content People animals and plants are composed mostly of water Make sure that these do not interfere with the module signal Maintain at least 0 5m distan...

Страница 9: ...be easily damaged and it is at least 300mm away from any other installed cables i e power lights PC data TV antenna etc If it is impossible to avoid running the ACM data cable close to the other cables run it across the other cables at 90 degree do not run in parallel Run the ACM data cable from the Indoor Unit to the ACM 3m ACM Data Cable from the Indoor Unit ActronConnect Module Step 1 2 6 Secur...

Страница 10: ...en screw Antenna into ACM socket and align as per instructions on Appendix A Requirements for ACM Optimum Signal Performance ACM Data Socket ACM Antenna Socket Antenna ACM Data Socket PLUG C RJ45 Data Plug Antenna ACM Data Socket Label ACM Data Socket Step 1 2 8 Check all connections cables to ensure correct connections and cables are secured properly Step 1 2 9 Power up the air conditioner by tur...

Страница 11: ...onConnect Commissioning Ensure that your home Wi Fi network is switched on and there is power to your air conditioner before setting up your ActronConnect system Step 2 1 Download the ActronConnect app from the Apple app store 1 2 Step 2 2 Open the ActronConnect app and press no account create one to create your ActronAir account 1 2 ...

Страница 12: ...e details in the required fields of the registration page i e your email address password post code You may also enter your details on the optional fields to help troubleshooting in the event you need to contact our Technical Support team in the future Then press submit to register your details NOTES 1 You can chose any password which is not necessarily the one you use for your email access 2 It i...

Страница 13: ...13 ActronConnect Installation Commissioning Guide Website Doc No 9590 1001 Version No 3 0 150901C Step 2 5 Set up your air conditioning type number of zones Then press next to proceed 3 4 5 6 1 2 ...

Страница 14: ...1C Step 2 6 When the Welcome page appear exit the ActronConnect app and go to your iOS device iphone ipad ipod etc Setting menu click on Wi Fi Step 2 7 Under devices select the ActronConnect Wi Fi network Press Join Anyway to proceed NOTE You may need to Turn On your Wi Fi if it is Turned Off 1 2 ...

Страница 15: ...e Wi Fi signal to appear before proceeding to the next step it can take up to 1 minute If it hasn t appeared continue with the set up process wait for approximate 1 minute Wi Fi signal Step 2 8 After establishing your air conditioner s Wi Fi network after connecting to ActronConnect re open the ActronConnect app and press next 1 2 ...

Страница 16: ...i Fi network password Illustrations below show how to select your SSID and how to enter and verify your Passphrase 1 Scroll Up Down to select your Wi Fi network name Example Your Network Name 2 NOTES 1 SSID Service Set Identifier the name of the wireless network All of the wireless devices on a wireless local area network WLAN must employ the same SSID in order to communicate with each other 2 Pas...

Страница 17: ... conditioner Wi Fi access is established the screen below will be displayed Do not press home Step 2 11 Close the ActronConnect app then go to Settings and connect to your router 1 2 NOTES 1 You are now connected to ActronConnect network 2 You must be within 15 meters between the installed ActronConnect Module and the configuration device iphone ipod PC to ensure optimum communication signals ...

Страница 18: ...901C Step 2 12 Re open the ActronConnect app and press the home button After you established the air conditioner and iOS network connectivity the ActronConnect home page as shown above will appear and you are now set to remotely operate and control your air conditioner by using your iOS device ...

Страница 19: ... IN DC OUT ADJ ACM POWER SUPPLY 240VAC 12VDC 1 3A IMPORTANT DO NOT MOUNT ACM DIRECTLY ON INDOOR UNIT FOR OPTIMUM PERFORMANCE OF WIFI SIGNAL MOUNT MINUMUM OF 1 METRE AWAY NOT ABOVE EVAPORATOR MOUNT MINIMUM 1 METRE BELOW ROOF ACTRON CONNECT MODULE ACM E2 RST MODE ETH AC PWR P1 BROWN BLUE GREEN YELLOW BRN WHITE GREEN BROWN BROWN BLUE ANTENNA 3G LPW WIFI ETH B WD0904 SRG V M 14 07 2013 MJH MJH 20 07 2...

Страница 20: ...ONE 4 FIELD WIRING BY INSTALLER FIELD WIRING FOR M SERIES CONTROLS ONLY 2A TX 20VA SEE JUMPER PIN POSITION TABLES ON UNIT WIRING DIAGRAM FOR CORRECT POSITION SENSOR WIRING FIELD WIRING BY INSTALLER CABLE MUST BE 2 CORE SHIELDED CABLE WITH SHIELD WIRE CONNECTED TO THE SCREEN COMMON TERMINAL EITHER 2C 14 0 20 SHIELDED OR 2C TWISTED PAIR 7 0 30 SHIELDED CABLE ACCEPTABLE TO OUTDOOR UNIT INDOOR FAN IF ...

Страница 21: ...ELD WIRING BY INSTALLER FIELD WIRING BY INSTALLER CABLE MUST BE 2 CORE SHIELDED CABLE WITH SHIELD WIRE CONNECTED TO THE SCREEN COMMON TERMINAL EITHER 2C 14 0 20 SHIELDED OR 2C TWISTED PAIR 7 0 30 SHIELDED CABLE ACCEPTABLE TO OUTDOOR UNIT INDOOR FAN IF INTERNAL AUTO RESET OVERLOAD PROTECTION FERRITE EMC 1 E N A N A POWER COM KEY SENSOR DO NOT CONNECT SCREEN AT WALL CONTROL SCREEN WIRES POWER COM KE...

Страница 22: ...O NOT CONNECT SCREEN AND SENSOR AT WALL CONTROL SEE JUMPER PIN POSITION TABLES FOR CORRECT SETTING ULTIMA MODULE 8Z VAV AMIB DATA ZONE 8 ZONE 7 ZONE 6 ZONE 5 ZONE 4 ZONE 3 ZONE 2 ZONE 1 TO ZONE 2 8 240V MAINS ZONE MOTOR ZONE CONTROL 1 ZONE SENSOR 1 LOG RJ45 SOCKETS FOR ACTRON AIR CAT5E SPEC CABLES ONLY FIELD WIRING FERRITE IF FITTED SCREEN WIRES DATA CABLE SCREEN WIRE KEEP AS SHORT AS POSSIBLE MAI...

Страница 23: ...D PAIR UNTIL TERMINAL ON AMIB FIELD WIRING BY INSTALLER CABLE MUST BE 2 CORE 7 0 30 SHIELDED TWISTED PAIR DATA CABLE WITH SCREEN WIRE CONNECTED TO THE SCREEN TERMINAL ON INDOOR UNIT SCREEN FOIL CLAMPED TO P CLIP ON OUTDOOR UNIT V V N A AC IN DC OUT ADJ ACM POWER SUPPLY 240VAC 12VDC 1 3A BROWN BLUE GREEN YELLOW BRN WHITE GREEN BROWN IMPORTANT DO NOT MOUNT WIFI MODULE DIRECTLY ON EVAPORATOR UNIT FOR...

Страница 24: ... com au Actron Engineering Pty Ltd ABN 34 002 767 240 HEAD OFFICE SYDNEY AUSTRALIA Copyright 2015 Actron Engineering Pty Ltd Printed in Australia Part No 9590 1001 Rev No 3 0 150901C Refrigerant Trading Authorisation No AU06394 ...

Отзывы: