Connections and Mounting Hardware
The IF input connection requires a coaxial cable with an F or N type connector. The RF output requires a
waveguide with a WR-75 flat flange. An O-ring shall be used to seal the waveguide connection.
Assembly and Installation
Use the information in this section as a guide to assemble and install the block up converter. The
specified humidity is up to 100% during operation. However, installation should be carried out in dry
conditions, free of salt spray or excessive humidity. This will eliminate the possibility of moisture and
other foreign substances from entering the output waveguide flange.
CAUTION!!
Only authorized technical personnel should perform the Installation and
proper electrical hookups of the block up converter.
The block up converter is designed to operate in an outdoor environment and is waterproof when
mounted in the correct orientation. To provide a sufficient airflow, the block up converter should be
mounted with a minimum clearance of 3 inches on all four sides and the bottom. Adequate cooling for
the block up converter will provide years of top performance.