SSPA

 

LED

 

Green

 

All

 

OK

 

SSPA

 

LED

 

Red

 

Summary

 

Alarm

 

L.O.

 

LED

 

Yellow

 

L.O.

 

is

 

set

 

to

 

4.9

 

GHz

 

NO

 

LED

 

indicators

 

NO

 

POWER

 

10MHz

 

LED

 

Green

 

External

 

10MHz

 

Reference

 

10MHz

 

LED

 

Red

 

10MHz

 

is

 

Absent

 

10MHz

 

LED

 

Green

 

Blinking

 

Internal

 

10MHz

 

Reference

 

 

 

10MHz

 

Reference

 

 

The

 

BUC

 

must

 

receive

 

a

 

stable

 

external

 

10MHz

 

reference

 

provided

 

by

 

a

 

stable

 

signal

 

source

 

such

 

as

 

a

 

signal

 

generator,

 

satellite

 

modem

 

or

 

injected

 

externally

 

with

 

a

 

Bias

 

T

 

(for

 

example,

 

ABT6ARN/ABT6ARF

 

manufactured

 

by

 

Actox

 

Corporation)

 

or

 

a

 

similar

 

bias

 

T

 

type.

 

 

Please

 

make

 

sure

 

to

 

check

 

the

 

sticker

 

on

 

the

 

BUC

 

for

 

the

 

appropriate

 

power

 

source

 

before

 

any

 

power

 

connections

 

are

 

performed.

 

 

 

 

 

 

 

 

 

 

 

LED

 

Indication

 

 

Содержание ABC40DC

Страница 1: ...ABC40DC User Manual Page 1 of 34 ABC40DC ABC40DCF 40 W Extended C Band BUC USER MANUAL...

Страница 2: ...escription 8 Considerations Securing the Block Up Converter Installing the Block Up Converter 9 LED Indicators Connector Pin Assignment 10MHz Reference Powering Options Setting L O Setting Tx Rx Frequ...

Страница 3: ...ocedure Block Up Converter Cooling System Preventive Maintenance Performance Check Troubleshooting Out of Warranty Repair Appendix 1 Technical Specifications 17 Appendix 2 Mechanical Drawing 18 Append...

Страница 4: ...tion and maintenance of the ABC40DC BUC It contains information intended for engineers technicians and operators working with the block up converter To make inquiries or to report errors of fact or om...

Страница 5: ...ed by unparalleled durability and dependability This is the smallest and lightest 40W L To C Band Block Up Converter and is designed to be mounted on the feed horn The unit is ideal for portable and m...

Страница 6: ...per packaging please notify Actox Corporation immediately Equipment Damage or Loss Actox Corporation is not responsible for damage or loss of equipment during transit For further information contact t...

Страница 7: ...f or others The block up converter must be installed in accordance with the conditions and recommendations contained in the following sections Safety Precautions Carelessness or mishandling of the blo...

Страница 8: ...erminated with a load of VSWR at 2 1 unless otherwise specified All RF specifications shall be met within five minutes after applying power except gain flatness which shall be met after a warm up peri...

Страница 9: ...antenna to the satellite Lightning arrestors should be used at the site to protect personnel and equipment Preparation Mounting Considerations Optional Mounting Brackets are available that will facili...

Страница 10: ...ng Internal 10MHz Reference 10MHz Reference The BUC must receive a stable external 10MHz reference provided by a stable signal source such as a signal generator satellite modem or injected externally...

Страница 11: ...h calibrated insertion loss up to 15GHz 40 dB attenuator High Power to match HPA output Assortment of cables connectors and adapters calibrated up to 18 GHz Ensure that the BUC TX output power is disa...

Страница 12: ...carried out in dry conditions free of salt spray or excessive humidity This will eliminate the possibility of moisture and other foreign substances from entering the output waveguide flange Only auth...

Страница 13: ...f the RF Amplifier provide the necessary gain and low insertion loss The amplified signal is transmitted through the output waveguide section to a satellite up link system Monitor and Control optional...

Страница 14: ...l result in personal injury Safe and careful installation of this block up converter will eliminate the possibility of accidents and provide years of top performance Verify the antenna feed waveguide...

Страница 15: ...ure to observe this precaution may result in personal injury or death This includes the removal of any RF power originating from other system components When the block up converter is in the hot stand...

Страница 16: ...he return loss From the output power measurements determine rated output power Record value on a test data sheet Measure the Two tone Inter modulation Suppression using two equal signals separated by...

Страница 17: ...ation TX Gain stability over temperature range 0 5 dB over 40MHz 1 8 dB over full band 1 5 dB typ 1 8 dB max Phase noise Exceeds Intelsat s standard IESS308 309 55 dBc Hz max 10 Hz 65 dBc Hz max 100 H...

Страница 18: ...ABC40DC User Manual Page 18 of 34 Appendix 2 Mechanical Drawing...

Страница 19: ...be sent via email to the following address Fax 1 866 888 6087 Email mark_moore actox com For additional information please contact our customer service department at 619 906 8893 or 1 866 888 6087 Act...

Страница 20: ...Temp 7E FF 84 06 06 TT TT ZZ 7F TT TT Device temp in C 273 ZZ CRC Temp 0x0102 0d258 273 15 C 2 cmd 7E FF 02 06 06 02 7F reply 7E FF 84 06 06 01 34 B1 7F Temp 0x0134 0d308 273 35 C Get Power Supply Te...

Страница 21: ...99 9 9V Command Packet format Explanation Possible replies Interpretation Examples Get Power Supply Current 7E FF 02 06 11 15 7F Query device for power supply current Update PS Current 7E FF 84 06 11...

Страница 22: ...0d105 0x0069 Set Low Power Alarm Threshold 7E FF 14 10 10 TT TT ZZ 7F Set low power alarm threshold Note zero value means low power alarm disabled ACK NACK TT TT Low power threshold in 10 x dBm ZZ CRC...

Страница 23: ...e element ACK command high nibble 0xE Acknowledge a received packet NACK command high nibble 0xF Reject a received packet Not ACKnowledge Data1 Datan contains the packet payload The value of the data...

Страница 24: ...atabase element 0x0606 from the Booster device address 0x0F the command is Example Only 7E FF 02 06 06 02 7F Dest Src 0xFF CMD Len 0x02 1111 1111 0000 0010 XOR 1111 1101 Data1 0x06 0000 0110 XOR 1111...

Страница 25: ...PC Laptop BUC connection to PC carried by cable with 19 pin female connector fig 1 on the one side and RJ45 fig 2 two DB9 fig 3 female connectors RS232 and RS485 on the other side Figure 1 1 19 pin co...

Страница 26: ...name From BUC pin NC NC R NC NC U NC NC K Ethernet 3 RX_P C 6 RX_N P 1 TX_P L 2 TX_N N RS 485 5 GNDISO A 4 TX_B H 3 TX_A T 1 RX_B F 2 RX_A S RS 232 5 GNDISO G 2 TX_RS 232 J 3 RX_RS 232 E NC MUTE_IN M...

Страница 27: ...rial Number Read only Factory set Each unit has a unique number Below the head you can find two tabs Monitor and Settings Monitor Tab Tab Monitor provides online telemetry of BUC Output Power Display...

Страница 28: ...nge according to the established L O o Green color frequency 26550Hz o Blinking green color frequency 27400Hz o Yellow color frequency 28050Hz o Blinking yellow color 29050HZ SSPA indicates Solid Stat...

Страница 29: ...Parameters IP Address Configurable Factory default 192 168 1 250 Default Gateway Configurable Factory default 192 168 1 1 Port Configurable Factory default 80 Subnet Mask Configurable Factory default...

Страница 30: ...efault enable Ref Button Changes button functions o Led sw switch on off LED s on dashboard o Ref sw switch on off auto detect function if BUC works on internal reference frequency Configurable Factor...

Страница 31: ...will see next page Figure 3 1 Start Page For log in type your login and password in appropriate fields There are two access levels User and Admin By default User s access level ID Login User Password...

Страница 32: ...configure options from the Monitor tab MUTE to change mode from MUTE to UNMUTE click button Switch 10MHZ to change mode from INTERNAL to EXTERNAL click button Switch L O choose right Local Oscillatio...

Страница 33: ...parameters DHCP status IP Address Subnet Mask Default Gateway Port and MAC Address connection speed for RS232 and RS485 ports and BUC address Right panel designed to change login configurations such a...

Страница 34: ...changes you must reboot your device New Community you can set password for SNMP browser Without this password you wouldn t get access to BUC via SNMP browser Type new password in the green field In f...

Отзывы: