ABC25UKA Manual
Page 29 of 36
BUC
User
Manual
via
PC
Run
NewBuc v.301
on your PC, when it opened you will see next window:
Figure 2.1 — Start window with
Monitor
Tab
In the head there is device information, such as:
Device Name
: Name that you can give to your device (You can change device name
in the tab
Settings
)
Model Number
: Read only. Factory set. Presents model of your device.
Operation Time
: The time that was passed since
BUC
was switch on.
Serial Number
: Read only. Factory set. Each unit has a unique number.
Below the head you can find two tabs:
Monitor
and
Settings.
Monitor
Tab
Tab
Monitor
provides online telemetry of
BUC:
Output Power:
Display the output detector value in W and dBm.
Internal Temp:
Display the
BUC
Hot spot temperature in degree Celsius.
Internal Voltage:
Display the
BUC
input voltage value in volts.
Current Draw:
Display the
BUC
input current value in amperes.
Gain:
Display the
BUC
gain value in dB.
Attenuation:
Configurable parameter. Controls gain attenuation. For change
attenuation lever (from 0 db to 20 db) fill new value in the field and click button
Set
to apply changes.