background image

HEAVY-DUTY ACTIVEPURE® AIR SYSTEM

OWNER’S MANUAL • INSTALLATION & MAINTENANCE GUIDE

CAUTION: Read manual carefully for proper procedures and operation.

Содержание ACTIVEPURE

Страница 1: ...HEAVY DUTY ACTIVEPURE AIR SYSTEM OWNER S MANUAL INSTALLATION MAINTENANCE GUIDE CAUTION Read manual carefully for proper procedures and operation ...

Страница 2: ...talling the Ballasts 11 Installing the ActivePure Cells 12 Installing the ActivePure Plate 12 Adjusting the Pressure Switch 13 Warranty 15 Replacement Parts List 16 CONTENTS Location for Protective Earth Line To reduce the risk of electric shock this equipment has a grounding type plug that has a third grounding pin This plug will only fit into a grounding type power outlet If the plug does not fi...

Страница 3: ...amps power consumption Mechanical 549 CFM fan 4 function rotary switch Rocker style power on off switch Size Height 13 Width 37 Depth 13 H 33cm W 94cm D 33cm Weight 58 pounds W 26 308 kg Ozone Output Low level O3 production Warranty See page 15 Secure No Duct Work Required No Chemicals Low Maintenance Complete User Control Plugs into 120 volt outlet Filter Cartridges specific to use FEATURES SPECI...

Страница 4: ...ses the air as it travels through the unit 4 PRINCIPLES OF OPERATION 1 Remove unit from shipping carton 2 Remove all protective materials 3 Check for shipping damage and loose or broken parts 4 Read Owner s Manual thoroughly prior to installation 5 Determine placement location for the unit plug the unit into a 120 volt outlet and adjust controls according to the application INSPECTION Power Cord M...

Страница 5: ...ch functions by turning clockwise to select power mode The SelectPURE unit should be installed within 7 feet of a standard 120 volt outlet to accommodate the power cord The SelectPURE unit should be secured into wall studs if possible Mounting holes are on 16 inch centers to accommodate installation to be secured into wall studs See mounting holes indicated in illustration on page 4 Fasteners are ...

Страница 6: ... 4 4 Plug in unit to grounded 120V outlet only 6 OPENING THE GRILLS 11 Remove the ten 10 screws in the SelectPURE grills from both ends 2 2 a Lift cover b Slide toward back of unit to remove c Repeat for other grill CAUTION Unplug the unit before performing any maintenance procedures Filter Cartridges follow steps 1 6 pg 7 ActivePure Plate follow steps 1 4 pg 8 ActivePure Cell follow steps 1 4 pg ...

Страница 7: ...upport frame from front of the filter chassis Order and contents will vary depending on your machine s purpose 4 4 Remove filter from chassis 5 5 Remove cartridge from chassis 6 6 Discard and replace old cartridges and filters Reverse steps to install new cartridges and filters See SelectPURE parts list on page 15 for a complete list of cartridges and filters ...

Страница 8: ...s page 6 2 2 Remove the two 2 phillips head screws located in the flange of the ActivePure plate 4 4 Disconnect power couplings and remove plate from chassis REMOVING THE ACTIVEPURE PLATE 3 3 Slide ActivePure plate forward over the adjustment tube and tilt outward Adjustment Tube ...

Страница 9: ... outward 2 2 Lay plate on flat surface 4 4 Remove the second small cell from mounting bracket in the same manner REMOVING THE ACTIVEPURE CELLS See SelectPURE parts list on page 16 to reference the ActivePure Cells 1 1 Remove ActivePure Plate See Removing the ActivePure Plate page 8 Mounting Bracket To remove the ballasts continue to next page To reassemble continue to page 12 ...

Страница 10: ...ActivePure plate 5 5 Remove the screws 2 from the second ballast 2 2 Remove the screws 2 from the mounting bracket connected to the ActivePure plate See SelectPURE parts list on page 16 to reference the ActivePure Cells 11 Remove ActivePure Plate See Removing the ActivePure Plate page 8 To reassemble continue to next page 6 6 Dispose of ballasts mounting brackets and wire assembly ...

Страница 11: ...tretch out and organize the replacement ballasts mounting brackets and wiring assembly 2 2 Line up ballasts and wiring with appropriate positions on ActivePure plate To install ActivePure Cells continue to next page 5 5 Replace screws 2 connecting mounting bracket to the ActivePure Plate Tighten securely 6 6 Repeat step 5 for second mounting bracket ...

Страница 12: ...ert the ActivePure plate flange screws into the flange and screw them back in with the phillips screwdriver 2 2 Slide ActivePure plate back into the chassis of unit being sure to fit the adjusting tube into the tube hole on the ActivePure plate INSTALLING THE ACTIVEPURE PLATE 11 Slide plate back into unit Re insert the power coupling 4 4 Reinstall grills and screw into place ...

Страница 13: ...witch as follows 3 3 Insert a flat headed screwdriver 7 inch minimum screwdriver shaft into the Adjustment Tube It will line up with the Adjustment Screw 11 Install new filters and cartridges following Steps 1 2 Opening the Grills page 6 Steps 1 6 Change the Filter and Cartridge page 7 2 2 Remove the right side grill opposite end of control panel following steps 1 2 Opening the Grills page 6 Turn ...

Страница 14: ...iece of paper on the unit s air inlet to restrict air flow This will mimic the restriction level to be adjusted to Clockwise rotation of screwdriver will increase the setting of the switch Counter clockwise rotation of screwdriver will decrease the setting of the switch 5 5 For specific questions on this adjustment process contact activTek Customer Service at 866 736 0503 6 6 Reinstall grills reve...

Страница 15: ... CONDITIONS EXCEPT AS PROVIDED HEREIN WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY DISCLAIMED INCLUD ING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE LIMITATION OF LIABILITY FOR SPE CIAL INCIDENTAL OR CONSEQUEN TIAL DAMAGES WE SHALL NOT IN ANY CASE BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQ...

Страница 16: ...T PARTS LIST Part Name Part Number ActivePure Cell Large US71081 ActivePure Cell Small US71114 Replacement Ballast US71113 Ultra Cartridge 3 inch US70709 Multi Plus Cartridge 2 inch US70710 Multi Cartridge 1 inch US70711 FOG Grease Cartridge 1 inch US70712 VOC Cartridge 1 inch US70713 Mercury Cartridge 1 inch US70714 65 00374 P65 00374 ...